Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -39,45 +39,45 @@ 39 39 Below is the list of internal BMS signals. The signals marked with bold text can be assigned to discrete outputs and relays. 40 40 41 41 (% style="width:1277px" %) 42 -|=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 140px;" %)BMSDisplay|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus**43 -|=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** |=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation44 -|Allow charging|C ommandfor a charger to start charging|Yes|Yes|Yes|(% style="width:140px" %) |ACH|(% style="width:140px" %) |(% style="width:142px" %)45 -|Balancing 1| Command tobalancethe first series of cells| |Yes*|Yes|(% style="width:140px" %) |BA1|(% style="width:140px" %) |(% style="width:142px" %)46 -|Balancing 2| Command tobalancethe second series of cells| |Yes*|Yes|(% style="width:140px" %) |BA2|(% style="width:140px" %) |(% style="width:142px" %)47 -|Cell analysis| Signalindicating cell analysis process|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |CEA|(% style="width:140px" %) |(% style="width:142px" %)48 -|Charging current present| Signal showingthe presence of the charging current|Yes|Yes~*~*|Yes|(% style="width:140px" %) |CCP|(% style="width:140px" %) |(% style="width:142px" %)49 -|Charging|C ommandtocontrol the charging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |CH|(% style="width:140px" %) |(% style="width:142px" %)50 -|Charging/discharging|C ommandtocontrolthe charging/discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |C/D|(% style="width:140px" %) |(% style="width:142px" %)51 -|Cooler|Command to controlthecooler|Yes|Yes|Yes|(% style="width:140px" %) |COO|(% style="width:140px" %) |(% style="width:142px" %)52 -|Crown EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) | EWS|(% style="width:140px" %) |(% style="width:142px" %)53 -|Discharging (AUX)| Commandtocontrolthe auxiliary discharging contactor|Yes|Yes|Yes|(% style="width:140px" %) |AUX|(% style="width:140px" %) |(% style="width:142px" %)54 -|Discharging current present| Signal showingthe presence of the discharging current|Yes|Yes~*~*|Yes|(% style="width:140px" %) |DCP|(% style="width:140px" %) |(% style="width:142px" %)55 -|Discharging|C ommandtocontrolthe discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |DCH|(% style="width:140px" %) |(% style="width:142px" %)56 -|External 1| Commandtocontrol|Yes|Yes|Yes|(% style="width:140px" %) |EX1|(% style="width:140px" %) |(% style="width:142px" %)57 -|Heater (AUX)| | |Yes| |(% style="width:140px" %) | HA|(% style="width:140px" %) |(% style="width:142px" %)58 -|Heater|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) | HEA|(% style="width:140px" %) |(% style="width:142px" %)59 -|High charging current|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) | HCC|(% style="width:140px" %) |(% style="width:142px" %)60 -|Init| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) | INI|(% style="width:140px" %) |(% style="width:142px" %)61 -|Low SOC|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) | LOS|(% style="width:140px" %) |(% style="width:142px" %)62 -|Main contactor|state of the main contactor;|Yes|Yes*|Yes|(% style="width:140px" %) | MCO|(% style="width:140px" %) |(% style="width:142px" %)63 -|Power down ACK|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) | PDA|(% style="width:140px" %) |(% style="width:142px" %)64 -|Power up|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) | PUP|(% style="width:140px" %) |(% style="width:142px" %)65 -|Precharging|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) | PRE|(% style="width:140px" %) |(% style="width:142px" %)66 -|Ready to charge|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) | RTC|(% style="width:140px" %) |(% style="width:142px" %)67 -|Ready to discharge|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) | RTD|(% style="width:140px" %) |(% style="width:142px" %)68 -|Service reset| |Yes~*~**| |Yes~*~**|(% style="width:140px" %) | SR|(% style="width:140px" %) |(% style="width:142px" %)69 -|Shutdown request (Combilift)| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) | CSH|(% style="width:140px" %) |(% style="width:142px" %)70 -|Shutdown request (HYG/Spirit)| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) | HSH|(% style="width:140px" %) |(% style="width:142px" %)71 -|Voltage too high for charging| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) | ENV|(% style="width:140px" %) |(% style="width:142px" %)42 +|=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% rowspan="2" style="width: 140px;" %) |=(% rowspan="2" style="width: 140px;" %) |=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 43 +|=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 44 +|Allow charging|ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 45 +|Balancing 1|BA1|balancing the first series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 46 +|Balancing 2|BA2|balancing the second series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 47 +|Cell analysis|CEA| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 48 +|Charging current present|CCP|the presence of the charging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 49 +|Charging|CH|state of the charging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 50 +|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 51 +|Cooler|COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 52 +|Crown EWS|EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 53 +|Discharging (AUX)|AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 54 +|Discharging current present|DCP|the presence of the discharging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 55 +|Discharging|DCH|state of the discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 56 +|External 1|EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 57 +|Heater (AUX)|HA| | |Yes| |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 58 +|Heater|HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 59 +|High charging current|HCC|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 60 +|Init|INI| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 61 +|Low SOC|LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 62 +|Main contactor|MCO|state of the main contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 63 +|Power down ACK|PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 64 +|Power up|PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 65 +|Precharging|PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 66 +|Ready to charge|RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 67 +|Ready to discharge|RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 68 +|Service reset|SR| |Yes~*~**| |Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 69 +|Shutdown request (Combilift)|CSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 70 +|Shutdown request (HYG/Spirit)|HSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 71 +|Voltage too high for charging|ENV| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 72 72 73 73 (% class="wikigeneratedid" %) 74 -~* Assignable to relay only74 +~* assignable to relay only 75 75 76 76 (% class="wikigeneratedid" %) 77 -~** Assignable to discrete input only77 +~** assignable to discrete input only 78 78 79 79 (% class="wikigeneratedid" %) 80 -~*~*~* Cannot be assigned to discrete output or relay.80 +~*~*~* cannot be assigned to discrete output or relay. 81 81 82 82 == List of errors == 83 83