Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -46,14 +46,14 @@ 46 46 |Balancing 2|Command to balance the second series of cells| |Yes*|Yes|(% style="width:140px" %) |BA2|(% style="width:140px" %) |(% style="width:142px" %) 47 47 |Cell analysis|Signal indicating cell analysis process|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |CEA|(% style="width:140px" %) |(% style="width:142px" %) 48 48 |Charging current present|Signal showing the presence of the charging current|Yes|Yes~*~*|Yes|(% style="width:140px" %) |CCP|(% style="width:140px" %) |(% style="width:142px" %) 49 -|Charging| stateofthe charging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |CH|(% style="width:140px" %) |(% style="width:142px" %)50 -|Charging/discharging| stateofthe charging/discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |C/D|(% style="width:140px" %) |(% style="width:142px" %)51 -|Cooler| a command to turnonacooler;|Yes|Yes|Yes|(% style="width:140px" %) |COO|(% style="width:140px" %) |(% style="width:142px" %)49 +|Charging|Command to control the charging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |CH|(% style="width:140px" %) |(% style="width:142px" %) 50 +|Charging/discharging|Command to control the charging/discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |C/D|(% style="width:140px" %) |(% style="width:142px" %) 51 +|Cooler|Command to control the cooler|Yes|Yes|Yes|(% style="width:140px" %) |COO|(% style="width:140px" %) |(% style="width:142px" %) 52 52 |Crown EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |EWS|(% style="width:140px" %) |(% style="width:142px" %) 53 -|Discharging (AUX)| stateofthe auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |AUX|(% style="width:140px" %) |(% style="width:142px" %)54 -|Discharging current present|the presence of the discharging current ;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |DCP|(% style="width:140px" %) |(% style="width:142px" %)55 -|Discharging| stateofthe discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |DCH|(% style="width:140px" %) |(% style="width:142px" %)56 -|External 1|a signalthatactivates by the remoterequest.|Yes|Yes|Yes|(% style="width:140px" %) |EX1|(% style="width:140px" %) |(% style="width:142px" %)53 +|Discharging (AUX)|Command to control the auxiliary discharging contactor|Yes|Yes|Yes|(% style="width:140px" %) |AUX|(% style="width:140px" %) |(% style="width:142px" %) 54 +|Discharging current present|Signal showing the presence of the discharging current|Yes|Yes~*~*|Yes|(% style="width:140px" %) |DCP|(% style="width:140px" %) |(% style="width:142px" %) 55 +|Discharging|Command to control the discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |DCH|(% style="width:140px" %) |(% style="width:142px" %) 56 +|External 1|Command to control|Yes|Yes|Yes|(% style="width:140px" %) |EX1|(% style="width:140px" %) |(% style="width:142px" %) 57 57 |Heater (AUX)| | |Yes| |(% style="width:140px" %) |HA|(% style="width:140px" %) |(% style="width:142px" %) 58 58 |Heater|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |HEA|(% style="width:140px" %) |(% style="width:142px" %) 59 59 |High charging current|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |HCC|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -71,13 +71,13 @@ 71 71 |Voltage too high for charging| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |ENV|(% style="width:140px" %) |(% style="width:142px" %) 72 72 73 73 (% class="wikigeneratedid" %) 74 -~* assignable to relay only74 +~* Assignable to relay only 75 75 76 76 (% class="wikigeneratedid" %) 77 -~** assignable to discrete input only77 +~** Assignable to discrete input only 78 78 79 79 (% class="wikigeneratedid" %) 80 -~*~*~* cannot be assigned to discrete output or relay.80 +~*~*~* Cannot be assigned to discrete output or relay. 81 81 82 82 == List of errors == 83 83