Last modified by Admin on 2025/03/03 15:20

From version 17.18
edited by Admin
on 2025/01/31 09:27
Change comment: There is no comment for this version
To version 18.2
edited by Admin
on 2025/01/31 10:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -41,13 +41,13 @@
41 41  (% style="width:1277px" %)
42 42  |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 140px;" %)BMS Display|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus**
43 43  |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation
44 -|Allow charging|Command for a charger to start charging|Yes|Yes|Yes|(% style="width:140px" %) |ACH|(% style="width:140px" %) |(% style="width:142px" %)
45 -|Balancing 1|Command to balance the first series of cells| |Yes*|Yes|(% style="width:140px" %) |BA1|(% style="width:140px" %) |(% style="width:142px" %)
46 -|Balancing 2|Command to balance the second series of cells| |Yes*|Yes|(% style="width:140px" %) |BA2|(% style="width:140px" %) |(% style="width:142px" %)
47 -|Cell analysis|Signal indicating cell analysis process|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |CEA|(% style="width:140px" %) |(% style="width:142px" %)
48 -|Charging current present|Signal showing the presence of the charging current|Yes|Yes~*~*|Yes|(% style="width:140px" %) |CCP|(% style="width:140px" %) |(% style="width:142px" %)
49 -|Charging|Command to control the charging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |CH|(% style="width:140px" %) |(% style="width:142px" %)
50 -|Charging/discharging|Command to control the charging/discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |C/D|(% style="width:140px" %) |(% style="width:142px" %)
44 +|Allow charging|Command for a charger to start charging|Yes|Yes|Yes|(% style="width:140px" %)Allow charging|ACH|(% style="width:140px" %) |(% style="width:142px" %)
45 +|Balancing 1|Command to balance the first series of cells| |Yes*|Yes|(% style="width:140px" %)Balancing 1|BA1|(% style="width:140px" %) |(% style="width:142px" %)
46 +|Balancing 2|Command to balance the second series of cells| |Yes*|Yes|(% style="width:140px" %)Balancing 2|BA2|(% style="width:140px" %) |(% style="width:142px" %)
47 +|Cell analysis|Signal indicating cell analysis process|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Cell analysis|CEA|(% style="width:140px" %) |(% style="width:142px" %)
48 +|Charging current present|Signal showing the presence of the charging current|Yes|Yes~*~*|Yes|(% style="width:140px" %)CH curr. present|CCP|(% style="width:140px" %) |(% style="width:142px" %)
49 +|Charging|Command to control the charging contactor|Yes|Yes*|Yes|(% style="width:140px" %)Charging|CH|(% style="width:140px" %) |(% style="width:142px" %)
50 +|Charging/Discharging|Command to control the charging/discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |C/D|(% style="width:140px" %) |(% style="width:142px" %)
51 51  |Cooler|Command to control the cooler|Yes|Yes|Yes|(% style="width:140px" %) |COO|(% style="width:140px" %) |(% style="width:142px" %)
52 52  |Crown EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |EWS|(% style="width:140px" %) |(% style="width:142px" %)
53 53  |Discharging (AUX)|Command to control the auxiliary discharging contactor|Yes|Yes|Yes|(% style="width:140px" %) |AUX|(% style="width:140px" %) |(% style="width:142px" %)
... ... @@ -64,11 +64,11 @@
64 64  |Power up|Signal indicating the BMS power status|Yes|Yes|Yes|(% style="width:140px" %) |PUP|(% style="width:140px" %) |(% style="width:142px" %)
65 65  |Precharging|Command to control the precharging contactor|Yes|Yes|Yes|(% style="width:140px" %) |PRE|(% style="width:140px" %) |(% style="width:142px" %)
66 66  |Ready to charge|Signal showing that the battery is ready for charging|Yes|Yes|Yes|(% style="width:140px" %) |RTC|(% style="width:140px" %) |(% style="width:142px" %)
67 -|Ready to discharge|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |RTD|(% style="width:140px" %) |(% style="width:142px" %)
68 -|Service reset| |Yes~*~**| |Yes~*~**|(% style="width:140px" %) |SR|(% style="width:140px" %) |(% style="width:142px" %)
69 -|Shutdown request (Combilift)| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |CSH|(% style="width:140px" %) |(% style="width:142px" %)
70 -|Shutdown request (HYG/Spirit)| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |HSH|(% style="width:140px" %) |(% style="width:142px" %)
71 -|Voltage too high for charging| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |ENV|(% style="width:140px" %) |(% style="width:142px" %)
67 +|Ready to discharge|Signal showing that the battery is ready for discharging|Yes|Yes|Yes|(% style="width:140px" %) |RTD|(% style="width:140px" %) |(% style="width:142px" %)
68 +|Service reset|Command to restart the device|Yes~*~**| |Yes~*~**|(% style="width:140px" %) |SR|(% style="width:140px" %) |(% style="width:142px" %)
69 +|Shutdown request (Combilift)|Command to open the dischrging contactor from the Combilift truck|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |CSH|(% style="width:140px" %) |(% style="width:142px" %)
70 +|Shutdown request (HYG/Spirit)|Command to open the dischrging contactor from the HYG truck|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |HSH|(% style="width:140px" %) |(% style="width:142px" %)
71 +|Voltage too high for charging|Signal indicating that the battery is fully charged|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |ENV|(% style="width:140px" %) |(% style="width:142px" %)
72 72  
73 73  (% class="wikigeneratedid" %)
74 74  ~* Assignable to relay only