Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,9 @@ 1 1 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Signals, states and errors = 3 3 4 -== Input signals ==4 +== List of input signals == 5 5 6 - Belowis the list of input signals that can be assigned to discrete inputs oftheBMS controller.6 +Here is the list of input signals that can be assigned to discrete inputs of BMS controller. 7 7 8 8 (% style="width:1278px" %) 9 9 |=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 500px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 243px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 137px;" %)BMS DIsplay|=(% colspan="1" rowspan="2" style="width: 137px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**Modbus** ... ... @@ -18,25 +18,25 @@ 18 18 |Close External 1|(% style="width:500px" %)Request to set the External 1 signal|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Close Ext.1|CE1|(% style="width:137px" %) |(% style="width:137px" %) 19 19 |Close Main contactor|(% style="width:500px" %)Request to close the main contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Close Main cont.|CMC|(% style="width:137px" %) |(% style="width:137px" %) 20 20 |DCH contactor feedback|(% style="width:500px" %)Signal from the discharging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)DCH cont. feed.|DCF|(% style="width:137px" %) |(% style="width:137px" %) 21 -|Discharge request|(% style="width:500px" %)Request to close the discharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) Dischargereq.|DRE|(% style="width:137px" %) |(% style="width:137px" %)22 -|Fuse 1|(% style="width:500px" %)Signal from fuse 1|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) Fuse1|F1|(% style="width:137px" %) |(% style="width:137px" %)23 -|Fuse 2|(% style="width:500px" %)Signal from fuse 2|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) Fuse2|F2|(% style="width:137px" %) |(% style="width:137px" %)24 -|Fuse 3|(% style="width:500px" %)Signal from fuse 3|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) Fuse3|F3|(% style="width:137px" %) |(% style="width:137px" %)25 -|Inhibit charging|(% style="width:500px" %)Command to open the charging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) Inhibitcharg.|ICH|(% style="width:137px" %) |(% style="width:137px" %)26 -|Inhibit discharging|(% style="width:500px" %)Command to open the discharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) Inhibitdisch.|IDC|(% style="width:137px" %) |(% style="width:137px" %)27 -|Insulation status|(% style="width:500px" %)Signal from an insulation monitoring device|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) Insul.status|INS|(% style="width:137px" %) |(% style="width:137px" %)28 -|Interlock|(% style="width:500px" %)Signal from the interlock loop|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) Interlock|INT|(% style="width:137px" %) |(% style="width:137px" %)29 -|Main contactor feedback|(% style="width:500px" %)Signal from the main contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) Maincont. feed.|MCF|(% style="width:137px" %) |(% style="width:137px" %)30 -|PCH contactor feedback|(% style="width:500px" %)Signal from the precharging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) PCHcont. feed.|PCF|(% style="width:137px" %) |(% style="width:137px" %)31 -|Power up/down request|(% style="width:500px" %)Request to power down the device|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) Powerdown req.|PDN|(% style="width:137px" %) |(% style="width:137px" %)32 -|Precharge request|(% style="width:500px" %)Request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) Prechargereq.|PRE|(% style="width:137px" %) |(% style="width:137px" %)21 +|Discharge request|(% style="width:500px" %)Request to close the discharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |DRE|(% style="width:137px" %) |(% style="width:137px" %) 22 +|Fuse 1|(% style="width:500px" %)Signal from fuse 1|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |F1|(% style="width:137px" %) |(% style="width:137px" %) 23 +|Fuse 2|(% style="width:500px" %)Signal from fuse 2|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |F2|(% style="width:137px" %) |(% style="width:137px" %) 24 +|Fuse 3|(% style="width:500px" %)Signal from fuse 3|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |F3|(% style="width:137px" %) |(% style="width:137px" %) 25 +|Inhibit charging|(% style="width:500px" %)Command to open the charging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |ICH|(% style="width:137px" %) |(% style="width:137px" %) 26 +|Inhibit discharging|(% style="width:500px" %)Command to open the discharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |IDC|(% style="width:137px" %) |(% style="width:137px" %) 27 +|Insulation status|(% style="width:500px" %)Signal from an insulation monitoring device|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |INS|(% style="width:137px" %) |(% style="width:137px" %) 28 +|Interlock|(% style="width:500px" %)Signal from the interlock loop|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) | |(% style="width:137px" %) |(% style="width:137px" %) 29 +|Main contactor feedback|(% style="width:500px" %)Signal from the main contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |MCF|(% style="width:137px" %) |(% style="width:137px" %) 30 +|PCH contactor feedback|(% style="width:500px" %)Signal from the precharging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |PCF|(% style="width:137px" %) |(% style="width:137px" %) 31 +|Power up/down request|(% style="width:500px" %)Request to power down the device|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |PDN|(% style="width:137px" %) |(% style="width:137px" %) 32 +|Precharge request|(% style="width:500px" %)Request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |PRE|(% style="width:137px" %) |(% style="width:137px" %) 33 33 34 34 (% class="wikigeneratedid" %) 35 35 ~* Contactor feedback signals in BMS Mini / BMS Mini S are connected to [[X1 header>>doc:Battery management systems.BMS Mini S.2\. Installation and connection.WebHome||anchor="HHeaders"]] and configured in "Signals → MOSFETs → Contactors feedback" section. 36 36 37 -== Internal signals ==37 +== List of internal states == 38 38 39 - Belowis the list of internalBMSsignals.The signals marked with bold text can be assigned to discrete outputsarelays.39 +Here is the list of control internal states. Signals marked with bold text can be assigned to discrete output or relay. 40 40 41 41 (% style="width:1277px" %) 42 42 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus**