Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,30 +6,30 @@ 6 6 Here is the list of input signals that can be assigned to discrete inputs of BMS controller. 7 7 8 8 (% style="width:1278px" %) 9 -|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(%colspan="1" rowspan="2" style="width: 500px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 243px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 137px;" %)BMS DIsplay|=(% colspan="1" rowspan="2" style="width: 137px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**Modbus**9 +|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 500px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 243px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 137px;" %)BMS DIsplay|=(% colspan="1" rowspan="2" style="width: 137px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**Modbus** 10 10 |=(% style="width: 92px;" %)**Mini S / Mini**|=(% style="width: 73px;" %)**Main 2.1**|=(% style="width: 78px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation 11 -|Balancing request| BR|(% style="width:500px" %)a request to balance the cells;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)12 -|Battery cover| CVR|(% style="width:500px" %)a signal from the battery cover;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)13 -|CH contactor feedback| CCF|(% style="width:500px" %)a signal from charging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)14 -|CH/DCH contactor feedback| CDF|(% style="width:500px" %)a signal from charging/discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)15 -|Charge request| CRE|(% style="width:500px" %)a request to close the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)16 -|Charger connected| CON|(% style="width:500px" %)a signal indicating that charger is connected;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)17 -|Circuit breaker status| CBS|(% style="width:500px" %)status of protectiondisconnector;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)18 -|Close External 1| CE1|(% style="width:500px" %)a request toclose the External 1 discrete output(if assigned).|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)19 -|Close Main contactor| CMC|(% style="width:500px" %)a request to close the main contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)20 -|DCH contactor feedback| DCF|(% style="width:500px" %)a signal from discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)21 -|Discharge request| DRE|(% style="width:500px" %)a request to close the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)22 -|Fuse 1| F1|(% style="width:500px" %)signal from fuse 1;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)23 -|Fuse 2| F2|(% style="width:500px" %)signal from fuse 2;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)24 -|Fuse 3| F3|(% style="width:500px" %)signal from fuse 3;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)25 -|Inhibit charging| ICH|(% style="width:500px" %)a command to open the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)26 -|Inhibit discharging| IDC|(% style="width:500px" %)a command to open the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)27 -|Insulation status| INS|(% style="width:500px" %)a signal from an insulation monitoring device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)28 -|Interlock| |(% style="width:500px" %)a signal from interlock loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(%style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)29 -|Main contactor feedback| MCF|(% style="width:500px" %)a signal from main contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)30 -|PCH contactor feedback| PCF|(% style="width:500px" %)a signal from precharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)31 -|Power up/down request| PDN|(% style="width:500px" %)a request to power down the device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)32 -|Precharge request| PRE|(% style="width:500px" %)a request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)|(% style="width:137px" %) |(% style="width:137px" %)11 +|Balancing request|(% style="width:500px" %)Request to balance the cells|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |BR|(% style="width:137px" %) |(% style="width:137px" %) 12 +|Battery cover|(% style="width:500px" %)Signal from the battery cover|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |CVR|(% style="width:137px" %) |(% style="width:137px" %) 13 +|CH contactor feedback|(% style="width:500px" %)Signal from the charging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |CCF|(% style="width:137px" %) |(% style="width:137px" %) 14 +|CH/DCH contactor feedback|(% style="width:500px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |CDF|(% style="width:137px" %) |(% style="width:137px" %) 15 +|Charge request|(% style="width:500px" %)Request to close the charging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |CRE|(% style="width:137px" %) |(% style="width:137px" %) 16 +|Charger connected|(% style="width:500px" %)Signal indicating that the charger is connected|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |CON|(% style="width:137px" %) |(% style="width:137px" %) 17 +|Circuit breaker status|(% style="width:500px" %)Status of protective disconnector|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |CBS|(% style="width:137px" %) |(% style="width:137px" %) 18 +|Close External 1|(% style="width:500px" %)Request to set the External 1 discrete output|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |CE1|(% style="width:137px" %) |(% style="width:137px" %) 19 +|Close Main contactor|(% style="width:500px" %)a request to close the main contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |CMC|(% style="width:137px" %) |(% style="width:137px" %) 20 +|DCH contactor feedback|(% style="width:500px" %)a signal from discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |DCF|(% style="width:137px" %) |(% style="width:137px" %) 21 +|Discharge request|(% style="width:500px" %)a request to close the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |DRE|(% style="width:137px" %) |(% style="width:137px" %) 22 +|Fuse 1|(% style="width:500px" %)signal from fuse 1;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |F1|(% style="width:137px" %) |(% style="width:137px" %) 23 +|Fuse 2|(% style="width:500px" %)signal from fuse 2;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |F2|(% style="width:137px" %) |(% style="width:137px" %) 24 +|Fuse 3|(% style="width:500px" %)signal from fuse 3;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |F3|(% style="width:137px" %) |(% style="width:137px" %) 25 +|Inhibit charging|(% style="width:500px" %)a command to open the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |ICH|(% style="width:137px" %) |(% style="width:137px" %) 26 +|Inhibit discharging|(% style="width:500px" %)a command to open the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |IDC|(% style="width:137px" %) |(% style="width:137px" %) 27 +|Insulation status|(% style="width:500px" %)a signal from an insulation monitoring device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |INS|(% style="width:137px" %) |(% style="width:137px" %) 28 +|Interlock|(% style="width:500px" %)a signal from interlock loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) | |(% style="width:137px" %) |(% style="width:137px" %) 29 +|Main contactor feedback|(% style="width:500px" %)a signal from main contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |MCF|(% style="width:137px" %) |(% style="width:137px" %) 30 +|PCH contactor feedback|(% style="width:500px" %)a signal from precharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |PCF|(% style="width:137px" %) |(% style="width:137px" %) 31 +|Power up/down request|(% style="width:500px" %)a request to power down the device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |PDN|(% style="width:137px" %) |(% style="width:137px" %) 32 +|Precharge request|(% style="width:500px" %)a request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |PRE|(% style="width:137px" %) |(% style="width:137px" %) 33 33 34 34 (% class="wikigeneratedid" %) 35 35 ~* Contactor feedback signals in BMS Mini / BMS Mini S are connected to [[X1 header>>doc:Battery management systems.BMS Mini S.2\. Installation and connection.WebHome||anchor="HHeaders"]] and configured in "Signals → MOSFETs → Contactors feedback" section.