Last modified by Admin on 2025/03/03 15:20

From version 13.1
edited by Admin
on 2025/01/30 17:16
Change comment: There is no comment for this version
To version 11.21
edited by Admin
on 2025/01/30 17:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Signals, states and errors
1 +3.1
Content
... ... @@ -1,7 +1,10 @@
1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 += Configuration =
3 +
1 1  (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= Signals, states and errors =
5 +== General information ==
3 3  
4 -== List of input signals ==
7 +=== List of input signals ===
5 5  
6 6  Here is the list of input signals that can be assigned to discrete inputs of BMS controller.
7 7  
... ... @@ -34,7 +34,7 @@
34 34  (% class="wikigeneratedid" %)
35 35  ~* Contactor feedback signals in BMS Mini / BMS Mini S are connected to [[X1 header>>doc:Battery management systems.BMS Mini S.2\. Installation and connection.WebHome||anchor="HHeaders"]] and configured in "Signals → MOSFETs → Contactors feedback" section.
36 36  
37 -== List of internal states ==
40 +=== List of internal states ===
38 38  
39 39  Here is the list of control internal states. Signals marked with bold text can be assigned to discrete output or relay.
40 40  
... ... @@ -79,7 +79,7 @@
79 79  (% class="wikigeneratedid" %)
80 80  ~*~*~* state is indicative only and cannot be assigned to discrete output or relay.
81 81  
82 -== List of errors ==
85 +=== List of errors ===
83 83  
84 84  (% style="width:1279px" %)
85 85  |(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:58px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus**
... ... @@ -91,7 +91,7 @@
91 91  |CH contactor feedback error|CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
92 92  |CH/DCH contactor feedback error|CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
93 93  |Combilift offline|COM|connection with a Combilift forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
94 -|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of BMS Mini device| |Yes| | |(% style="width:142px" %) |(% style="width:134px" %)
97 +|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be found in Signals -> MOSFETs Contactor feedback section of BMS Mini device| |Yes| | |(% style="width:142px" %) |(% style="width:134px" %)
95 95  |Critical error|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
96 96  |Crown error|CRO|connection with a Crown forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
97 97  |Current limit error|CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %)