... ... @@ -32,7 +32,7 @@
32 32  |Main contactor feedback|MCF|(% style="width:500px" %)a signal from main contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
33 33  |PCH contactor feedback|PCF|(% style="width:500px" %)a signal from precharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
34 34  |Power up/down request|PDN|(% style="width:500px" %)a request to power down the device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
35 -|Precharge request|PRE|(% style="width:500px" %)a request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
35 +|Precharge request|PRE|(% style="width:500px" %)a request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %) |(% style="width:137px" %) |(% style="width:137px" %)
36 36  
37 37  (% class="wikigeneratedid" %)
38 38  ~* Contactor feedback signals in BMS Mini / BMS Mini S are connected to [[X1 header>>doc:Battery management systems.BMS Mini S.2\. Installation and connection.WebHome||anchor="HHeaders"]] and configured in "Signals → MOSFETs → Contactors feedback" section.
... ... @@ -57,7 +57,7 @@
57 57  |Discharging current present|DCP|the presence of the discharging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
58 58  |Discharging|DCH|state of the discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
59 59  |External 1|EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
60 -|Heater (AUX)|HA| | |Yes| |(% style="width:140px" %) |(% style="width:142px" %)
60 +|Heater (AUX)|HA| | |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
61 61  |Heater|HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
62 62  |High charging current|HCC|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
63 63  |Init|INI| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
... ... @@ -91,8 +91,8 @@
91 91  |Battery cover error|BC|battery cover is open;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
92 92  |Cell count error|CEL|number of cells does not match the specified value;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
93 93  |CH contactor cycles error|CCC|switching frequency of the charging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
94 -|CH contactor feedback error|CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
95 -|CH/DCH contactor feedback error|CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
94 +|CH contactor feedback error|CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %)
95 +|CH/DCH contactor feedback error|CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %)
96 96  |Combilift offline|COM|connection with a Combilift forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
97 97  |Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be | |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %)
98 98  |Critical error|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
... ... @@ -100,9 +100,9 @@
100 100  |Current limit error|CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %)
101 101  |Current sensor error|CSE|error in the current sensor circuit;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
102 102  |DCH contactor cycles error|DCC|switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
103 -|DCH contactor feedback error|DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
103 +|DCH contactor feedback error|DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %)
104 104  |FS error|FSE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
105 -|General error|GE| | |Yes*|Yes*|Yes*|(% style="width:142px" %) |(% style="width:134px" %)
105 +|General error|GE| | |Yes*|Yes*|Yes|(% style="width:142px" %) |(% style="width:134px" %)
106 106  |High contactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
107 107  |High humidity|HH|humidity of the battery is increased;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
108 108  |High Logic temperature|LHT|at least one of the Logic devices is overheated;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
... ... @@ -113,18 +113,16 @@
113 113  |HYG offline|HYG|connection with a HYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
114 114  |Insulation fault|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
115 115  |Logic count error|LOG| | | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
116 -|Logic offline|LOF|BMS Main devices: at least one of the Logic devices is offline;
117 -BMS Mini devices: connection with cell monitor lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
118 -|Cell monitor offline|LOF| | | | | |(% style="width:142px" %) |(% style="width:134px" %)
116 +|Logic offline|LOF|at least one of the Logic devices is offline;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
119 119  |Low temperature (CH)|LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
120 120  |Low temperature (DCH)|LDT|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
121 -|Main contactor feedback error|MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
119 +|Main contactor feedback error|MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %)
122 122  |Mount error|MNT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
123 123  |Need acknowledge|ACK|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
124 124  |No temperature sensors|NTS|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
125 125  |Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
126 126  |Overvoltage|OV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
127 -|PCH contactor feedback error|PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
125 +|PCH contactor feedback error|PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %)
128 128  |Power fault|PF|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)
129 129  |Power switch error|PSE|short circuit in contactor coil control circuit or power switch overheating;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)
130 130  |Precharge error|PE|capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)