Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 3.11 +Signals, states and errors - Content
-
... ... @@ -1,10 +4,7 @@ 1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration = 3 - 4 4 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 -= =Generalinformation ==2 += Signals, states and errors = 6 6 7 -== =List of input signals ===4 +== List of input signals == 8 8 9 9 Here is the list of input signals that can be assigned to discrete inputs of BMS controller. 10 10 ... ... @@ -37,7 +37,7 @@ 37 37 (% class="wikigeneratedid" %) 38 38 ~* Contactor feedback signals in BMS Mini / BMS Mini S are connected to [[X1 header>>doc:Battery management systems.BMS Mini S.2\. Installation and connection.WebHome||anchor="HHeaders"]] and configured in "Signals → MOSFETs → Contactors feedback" section. 39 39 40 -== =List of internal states ===37 +== List of internal states == 41 41 42 42 Here is the list of control internal states. Signals marked with bold text can be assigned to discrete output or relay. 43 43 ... ... @@ -80,9 +80,9 @@ 80 80 ~** assignable to discrete input only 81 81 82 82 (% class="wikigeneratedid" %) 83 -~*~*~* state is indicative only and cannot be assigned to discrete output or relay.80 +~*~*~* cannot be assigned to discrete output or relay. 84 84 85 -== =List of errors ===82 +== List of errors == 86 86 87 87 (% style="width:1279px" %) 88 88 |(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:58px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus** ... ... @@ -94,7 +94,7 @@ 94 94 |CH contactor feedback error|CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 95 95 |CH/DCH contactor feedback error|CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 96 96 |Combilift offline|COM|connection with a Combilift forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 97 -|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be found in Signals -> MOSFETs Contactor feedback section of BMS Mini device| |Yes| | |(% style="width:142px" %) |(% style="width:134px" %) 94 +|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of BMS Mini device| |Yes| | |(% style="width:142px" %) |(% style="width:134px" %) 98 98 |Critical error|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 99 99 |Crown error|CRO|connection with a Crown forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 100 |Current limit error|CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %)