Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 3.11 +Signals, states and errors - Content
-
... ... @@ -1,77 +4,74 @@ 1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration = 3 - 4 4 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 -= =Generalinformation ==2 += Signals, states and errors = 6 6 7 -== =List of input signals ===4 +== Input signals == 8 8 9 - Hereis the list of input signals that can be assigned to discrete inputs of BMS controller.6 +Below is the list of input signals that can be assigned to discrete inputs of the BMS controller. 10 10 11 11 (% style="width:1278px" %) 12 -|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width:500px;" %)**Description**|=(% colspan="3" rowspan="1" style="width:243px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**Modbus**13 -|=(% style="width: 92px;" %)**Mini S / Mini**|=(% style="width: 73px;" %)**Main 2.1**|=(% style="width: 78px;" %)**Main 3** 14 -|Balancing request| BR|(% style="width:500px" %)a request to balance the cells;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)15 -|Battery cover| CVR|(% style="width:500px" %)a signal from the battery cover;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)16 -|CH contactor feedback| CCF|(% style="width:500px" %)a signal from charging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)17 -|CH/DCH contactor feedback| CDF|(% style="width:500px" %)a signal from charging/discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)18 -|Charge request| CRE|(% style="width:500px" %)a request to close the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)19 -|Charger connected| CON|(% style="width:500px" %)a signal indicating that charger is connected;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)20 -|Circuit breaker status| CBS|(% style="width:500px" %)status of protectiondisconnector;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)21 -|Close External 1| CE1|(% style="width:500px" %)a request toclose the External 1discrete output (if assigned).|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)22 -|Close Main contactor| CMC|(% style="width:500px" %)a request to close the main contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)23 -|DCH contactor feedback| DCF|(% style="width:500px" %)a signal from discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)24 -|Discharge request| DRE|(% style="width:500px" %)a request to close the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)25 -|Fuse 1| F1|(% style="width:500px" %)signal from fuse 1;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)26 -|Fuse 2| F2|(% style="width:500px" %)signal from fuse 2;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)27 -|Fuse 3| F3|(% style="width:500px" %)signal from fuse 3;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)28 -|Inhibit charging| ICH|(% style="width:500px" %)a command to open the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)29 -|Inhibit discharging| IDC|(% style="width:500px" %)a command to open the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)30 -|Insulation status| INS|(% style="width:500px" %)a signal from an insulation monitoring device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)31 -|Interlock| |(% style="width:500px" %)a signal from interlock loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)32 -|Main contactor feedback| MCF|(% style="width:500px" %)a signal from main contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)33 -|PCH contactor feedback| PCF|(% style="width:500px" %)a signal from precharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)34 -|Power up/down request| PDN|(% style="width:500px" %)a request to power down the device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)35 -|Precharge request| PRE|(% style="width:500px" %)a request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)9 +|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 500px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 243px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 137px;" %)BMS DIsplay|=(% colspan="1" rowspan="2" style="width: 137px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**Modbus** 10 +|=(% style="width: 92px;" %)**Mini S / Mini**|=(% style="width: 73px;" %)**Main 2.1**|=(% style="width: 78px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation 11 +|Balancing request|(% style="width:500px" %)Request to balance the cells|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Balancing req.|BR|(% style="width:137px" %) |(% style="width:137px" %) 12 +|Battery cover|(% style="width:500px" %)Signal from the battery cover|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Battery cover|CVR|(% style="width:137px" %) |(% style="width:137px" %) 13 +|CH contactor feedback|(% style="width:500px" %)Signal from the charging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)CH cont. feed.|CCF|(% style="width:137px" %) |(% style="width:137px" %) 14 +|CH/DCH contactor feedback|(% style="width:500px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)DCH cont. feed.|DCF|(% style="width:137px" %) |(% style="width:137px" %) 15 +|Charge request|(% style="width:500px" %)Request to close the charging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Charge request|CRE|(% style="width:137px" %) |(% style="width:137px" %) 16 +|Charger connected|(% style="width:500px" %)Signal indicating that the charger is connected|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Charger connect.|CON|(% style="width:137px" %) |(% style="width:137px" %) 17 +|Circuit breaker status|(% style="width:500px" %)Status of protective disconnector|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Circuit breaker|CBS|(% style="width:137px" %) |(% style="width:137px" %) 18 +|Close External 1|(% style="width:500px" %)Request to set the External 1 signal|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Close Ext.1|CE1|(% style="width:137px" %) |(% style="width:137px" %) 19 +|Close Main contactor|(% style="width:500px" %)Request to close the main contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Close Main cont.|CMC|(% style="width:137px" %) |(% style="width:137px" %) 20 +|DCH contactor feedback|(% style="width:500px" %)Signal from the discharging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)DCH cont. feed.|DCF|(% style="width:137px" %) |(% style="width:137px" %) 21 +|Discharge request|(% style="width:500px" %)Request to close the discharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Discharge req.|DRE|(% style="width:137px" %) |(% style="width:137px" %) 22 +|Fuse 1|(% style="width:500px" %)Signal from fuse 1|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Fuse 1|F1|(% style="width:137px" %) |(% style="width:137px" %) 23 +|Fuse 2|(% style="width:500px" %)Signal from fuse 2|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Fuse 2|F2|(% style="width:137px" %) |(% style="width:137px" %) 24 +|Fuse 3|(% style="width:500px" %)Signal from fuse 3|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Fuse 3|F3|(% style="width:137px" %) |(% style="width:137px" %) 25 +|Inhibit charging|(% style="width:500px" %)Command to open the charging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Inhibit charg.|ICH|(% style="width:137px" %) |(% style="width:137px" %) 26 +|Inhibit discharging|(% style="width:500px" %)Command to open the discharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Inhibit disch.|IDC|(% style="width:137px" %) |(% style="width:137px" %) 27 +|Insulation status|(% style="width:500px" %)Signal from an insulation monitoring device|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Insul. status|INS|(% style="width:137px" %) |(% style="width:137px" %) 28 +|Interlock|(% style="width:500px" %)Signal from the interlock loop|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Interlock|INT|(% style="width:137px" %) |(% style="width:137px" %) 29 +|Main contactor feedback|(% style="width:500px" %)Signal from the main contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Main cont. feed.|MCF|(% style="width:137px" %) |(% style="width:137px" %) 30 +|PCH contactor feedback|(% style="width:500px" %)Signal from the precharging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)PCH cont. feed.|PCF|(% style="width:137px" %) |(% style="width:137px" %) 31 +|Power up/down request|(% style="width:500px" %)Request to power down the device|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Power down req.|PDN|(% style="width:137px" %) |(% style="width:137px" %) 32 +|Precharge request|(% style="width:500px" %)Request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Precharge req.|PRE|(% style="width:137px" %) |(% style="width:137px" %) 36 36 37 37 (% class="wikigeneratedid" %) 38 38 ~* Contactor feedback signals in BMS Mini / BMS Mini S are connected to [[X1 header>>doc:Battery management systems.BMS Mini S.2\. Installation and connection.WebHome||anchor="HHeaders"]] and configured in "Signals → MOSFETs → Contactors feedback" section. 39 39 40 -== =List of internal states ===37 +== Internal signals == 41 41 42 - Hereis the list ofcontrolinternal states.Signals marked with bold text can be assigned to discrete outputorrelay.39 +Below is the list of internal BMS signals. The signals marked with bold text can be assigned to discrete outputs and relays. 43 43 44 44 (% style="width:1277px" %) 45 -|=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 42 +|=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% rowspan="2" style="width: 140px;" %) |=(% rowspan="2" style="width: 140px;" %) |=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 46 46 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 47 -|Allow charging|ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 48 -|Balancing 1|BA1|balancing the first series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 49 -|Balancing 2|BA2|balancing the second series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 50 -|Cell analysis|CEA| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 51 -|Charging current present|CCP|the presence of the charging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 52 -|Charging|CH|state of the charging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 53 -|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 54 -|Cooler|COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 55 -|Crown EWS|EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 56 -|Discharging (AUX)|AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 57 -|Discharging current present|DCP|the presence of the discharging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 58 -|Discharging|DCH|state of the discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 59 -|External 1|EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 60 -|Heater (AUX)|HA| | |Yes| |(% style="width:140px" %) |(% style="width:142px" %) 61 -|Heater|HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 62 -|High charging current|HCC|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 63 -|Init|INI| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 64 -|Low SOC|LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 65 -|Main contactor|MCO|state of the main contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 66 -|Power down ACK|PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 67 -|Power up|PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 68 -|Precharging|PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 69 -|Ready to charge|RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 70 -|Ready to discharge|RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 71 -|Service reset|SR| |Yes~*~**| |Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 72 -|Shutdown request (Combilift)|CSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 73 -|Shutdown request (HYG/Spirit)|HSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 74 -|Voltage too high for charging|ENV| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 44 +|Allow charging|ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 45 +|Balancing 1|BA1|balancing the first series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 46 +|Balancing 2|BA2|balancing the second series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 47 +|Cell analysis|CEA| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 48 +|Charging current present|CCP|the presence of the charging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 49 +|Charging|CH|state of the charging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 50 +|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 51 +|Cooler|COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 52 +|Crown EWS|EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 53 +|Discharging (AUX)|AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 54 +|Discharging current present|DCP|the presence of the discharging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 55 +|Discharging|DCH|state of the discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 56 +|External 1|EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 57 +|Heater (AUX)|HA| | |Yes| |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 58 +|Heater|HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 59 +|High charging current|HCC|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 60 +|Init|INI| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 61 +|Low SOC|LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 62 +|Main contactor|MCO|state of the main contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 63 +|Power down ACK|PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 64 +|Power up|PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 65 +|Precharging|PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 66 +|Ready to charge|RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 67 +|Ready to discharge|RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 68 +|Service reset|SR| |Yes~*~**| |Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 69 +|Shutdown request (Combilift)|CSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 70 +|Shutdown request (HYG/Spirit)|HSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 71 +|Voltage too high for charging|ENV| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:140px" %) |(% style="width:142px" %) 75 75 76 76 (% class="wikigeneratedid" %) 77 77 ~* assignable to relay only ... ... @@ -80,9 +80,9 @@ 80 80 ~** assignable to discrete input only 81 81 82 82 (% class="wikigeneratedid" %) 83 -~*~*~* state is indicative only and cannot be assigned to discrete output or relay.80 +~*~*~* cannot be assigned to discrete output or relay. 84 84 85 -== =List of errors ===82 +== List of errors == 86 86 87 87 (% style="width:1279px" %) 88 88 |(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:58px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus** ... ... @@ -91,53 +91,53 @@ 91 91 |Battery cover error|BC|battery cover is open;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 92 92 |Cell count error|CEL|number of cells does not match the specified value;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 93 93 |CH contactor cycles error|CCC|switching frequency of the charging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 94 -|CH contactor feedback error|CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)95 -|CH/DCH contactor feedback error|CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)91 +|CH contactor feedback error|CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 92 +|CH/DCH contactor feedback error|CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 96 96 |Combilift offline|COM|connection with a Combilift forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 97 -|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be ||Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %)94 +|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of BMS Mini device| |Yes| | |(% style="width:142px" %) |(% style="width:134px" %) 98 98 |Critical error|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 99 99 |Crown error|CRO|connection with a Crown forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 -|Current limit error|CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| | **Yes**|(% style="width:142px" %) |(% style="width:134px" %)97 +|Current limit error|CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %) 101 101 |Current sensor error|CSE|error in the current sensor circuit;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 102 102 |DCH contactor cycles error|DCC|switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 103 -|DCH contactor feedback error|DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)104 -|FS error|FSE| | |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)105 -|General error|GE| | |Yes*|Yes*| **Yes***|(% style="width:142px" %) |(% style="width:134px" %)100 +|DCH contactor feedback error|DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 101 +|FS error|FSE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 102 +|General error|GE| | |Yes*|Yes*|Yes*|(% style="width:142px" %) |(% style="width:134px" %) 106 106 |High contactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 107 107 |High humidity|HH|humidity of the battery is increased;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 108 108 |High Logic temperature|LHT|at least one of the Logic devices is overheated;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 -|High temperature (CH)|HCT|temperature is too high for charging;| |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)106 +|High temperature (CH)|HCT|temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 110 110 |High temperature (DCH)|HDT|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 111 -|High voltage fault|HVF|failure of high voltage measuring circuits;|•| | | **Yes**|(% style="width:142px" %) |(% style="width:134px" %)112 -|HVIL error|HE|breakage of high-voltage interlock current loop;|•| | | **Yes**|(% style="width:142px" %) |(% style="width:134px" %)108 +|High voltage fault|HVF|failure of high voltage measuring circuits;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 +|HVIL error|HE|breakage of high-voltage interlock current loop;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 113 113 |HYG offline|HYG|connection with a HYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 114 -|Insulation fault|INF| |•|Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)111 +|Insulation fault|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 115 115 |Logic count error|LOG| | | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 116 116 |Logic offline 117 117 Cell monitor offline|LOF|BMS Main devices: at least one of the Logic devices is offline; 118 118 BMS Mini devices: connection with cell monitor lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 119 -|Low temperature (CH)|LCT|temperature is too low for charging;| |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)116 +|Low temperature (CH)|LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 120 120 |Low temperature (DCH)|LDT|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 121 -|Main contactor feedback error|MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)122 -|Mount error|MNT| | |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)118 +|Main contactor feedback error|MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 119 +|Mount error|MNT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 123 123 |Need acknowledge|ACK|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 124 -|No temperature sensors|NTS|the device has no temperature sensors connected;|•|Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)121 +|No temperature sensors|NTS|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 125 125 |Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 126 126 |Overvoltage|OV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 127 -|PCH contactor feedback error|PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)128 -|Power fault|PF|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | | **Yes**|(% style="width:142px" %) |(% style="width:134px" %)129 -|Power switch error|PSE|short circuit in contactor coil control circuit or power switch overheating;|•| | | **Yes**|(% style="width:142px" %) |(% style="width:134px" %)130 -|Precharge error|PE|capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)124 +|PCH contactor feedback error|PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 125 +|Power fault|PF|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 126 +|Power switch error|PSE|short circuit in contactor coil control circuit or power switch overheating;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 127 +|Precharge error|PE|capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 131 131 |Settings error|SET| | | | | |(% style="width:142px" %) |(% style="width:134px" %) 132 132 |Short circuit|SHC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 133 133 |Shunt error|SHE|internal error of the shunt current sensor;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 134 134 |Shunt offline|SHO|connection with the shunt current sensor is lost;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 135 -|Spirit offline|SPI|connection with a Spirit forklift is lost;| |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)136 -|Stuck contactor|STC| |•|Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)137 -|Temperature sensor is shorted|TSS|some temperature sensors are shorted;|•|Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)138 -|Unallowable charging|UCH|charging the battery through the discharging contactor;| |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)132 +|Spirit offline|SPI|connection with a Spirit forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 133 +|Stuck contactor|STC| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 134 +|Temperature sensor is shorted|TSS|some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 135 +|Unallowable charging|UCH|charging the battery through the discharging contactor;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 139 139 |Undervoltage|UV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 140 140 |Water|WA|there is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 141 -|WDT reset|WDT|watchdog timer reset the device;|•|Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)138 +|WDT reset|WDT|watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 142 142 143 143 ~* signal can be assigned to a discrete output and relay.