Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -121,7 +121,7 @@ 121 121 |Main contactor feedback error|MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 122 122 |Mount error|MNT| | |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 123 123 |Need acknowledge|ACK|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 124 -|No temperature sensors|NTS|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 124 +|No temperature sensors|NTS|the device has no temperature sensors connected;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 125 125 |Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 126 126 |Overvoltage|OV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 127 127 |PCH contactor feedback error|PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -130,14 +130,14 @@ 130 130 |Precharge error|PE|capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 131 131 |Settings error|SET| | | | | |(% style="width:142px" %) |(% style="width:134px" %) 132 132 |Short circuit|SHC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 133 -|Shunt error|SHE|internal error of the shunt current sensor;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 134 -|Shunt offline|SHO|connection with the shunt current sensor is lost;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 135 -|Spirit offline|SPI|connection with a Spirit forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 133 +|Shunt error|SHE|internal error of the shunt current sensor;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 134 +|Shunt offline|SHO|connection with the shunt current sensor is lost;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 135 +|Spirit offline|SPI|connection with a Spirit forklift is lost;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 136 136 |Stuck contactor|STC| |•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 137 -|Temperature sensor is shorted|TSS|some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 137 +|Temperature sensor is shorted|TSS|some temperature sensors are shorted;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 138 138 |Unallowable charging|UCH|charging the battery through the discharging contactor;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 139 139 |Undervoltage|UV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 140 140 |Water|WA|there is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 141 -|WDT reset|WDT|watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 141 +|WDT reset|WDT|watchdog timer reset the device;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 142 142 143 143 ~* signal can be assigned to a discrete output and relay.