... ... @@ -101,12 +101,12 @@ 101 101 |Current sensor error|CSE|error in the current sensor circuit;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 102 102 |DCH contactor cycles error|DCC|switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 103 103 |DCH contactor feedback error|DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 104 -|FS error|FSE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 104 +|FS error|FSE| | |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 105 105 |General error|GE| | |Yes*|Yes*|**Yes***|(% style="width:142px" %) |(% style="width:134px" %) 106 106 |High contactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 107 107 |High humidity|HH|humidity of the battery is increased;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 108 108 |High Logic temperature|LHT|at least one of the Logic devices is overheated;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 -|High temperature (CH)|HCT|temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 +|High temperature (CH)|HCT|temperature is too high for charging;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 110 110 |High temperature (DCH)|HDT|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 111 111 |High voltage fault|HVF|failure of high voltage measuring circuits;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 112 112 |HVIL error|HE|breakage of high-voltage interlock current loop;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -116,12 +116,12 @@ 116 116 |Logic offline 117 117 Cell monitor offline|LOF|BMS Main devices: at least one of the Logic devices is offline; 118 118 BMS Mini devices: connection with cell monitor lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 119 -|Low temperature (CH)|LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 119 +|Low temperature (CH)|LCT|temperature is too low for charging;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 120 120 |Low temperature (DCH)|LDT|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 121 121 |Main contactor feedback error|MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 122 -|Mount error|MNT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 122 +|Mount error|MNT| | |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 123 123 |Need acknowledge|ACK|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 124 -|No temperature sensors|NTS|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 124 +|No temperature sensors|NTS|the device has no temperature sensors connected;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 125 125 |Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 126 126 |Overvoltage|OV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 127 127 |PCH contactor feedback error|PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -132,12 +132,12 @@ 132 132 |Short circuit|SHC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 133 133 |Shunt error|SHE|internal error of the shunt current sensor;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 134 134 |Shunt offline|SHO|connection with the shunt current sensor is lost;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 135 -|Spirit offline|SPI|connection with a Spirit forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 135 +|Spirit offline|SPI|connection with a Spirit forklift is lost;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 136 136 |Stuck contactor|STC| |•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 137 -|Temperature sensor is shorted|TSS|some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 137 +|Temperature sensor is shorted|TSS|some temperature sensors are shorted;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 138 138 |Unallowable charging|UCH|charging the battery through the discharging contactor;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 139 139 |Undervoltage|UV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 140 140 |Water|WA|there is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 141 -|WDT reset|WDT|watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 141 +|WDT reset|WDT|watchdog timer reset the device;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 142 142 143 143 ~* signal can be assigned to a discrete output and relay.