Last modified by Admin on 2025/03/03 15:20

From version 11.1
edited by Admin
on 2025/01/30 16:46
Change comment: There is no comment for this version
To version 10.10
edited by Admin
on 2025/01/30 16:41
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,27 +11,27 @@
11 11  (% style="width:1278px" %)
12 12  |=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 500px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 243px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**Modbus**
13 13  |=(% style="width: 92px;" %)**Mini S / Mini**|=(% style="width: 73px;" %)**Main 2.1**|=(% style="width: 78px;" %)**Main 3**
14 -|Balancing request|BR|(% style="width:500px" %)a request to balance the cells;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
15 -|Battery cover|CVR|(% style="width:500px" %)a signal from the battery cover;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
16 -|CH contactor feedback|CCF|(% style="width:500px" %)a signal from charging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
17 -|CH/DCH contactor feedback|CDF|(% style="width:500px" %)a signal from charging/discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
18 -|Charge request|CRE|(% style="width:500px" %)a request to close the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
19 -|Charger connected|CON|(% style="width:500px" %)a signal indicating that charger is connected;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
20 -|Circuit breaker status|CBS|(% style="width:500px" %)status of protection disconnector;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
21 -|Close External 1|CE1|(% style="width:500px" %)a request to close the External 1 discrete output (if assigned).|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
22 -|Close Main contactor|CMC|(% style="width:500px" %)a request to close the main contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
23 -|DCH contactor feedback|DCF|(% style="width:500px" %)a signal from discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
24 -|Discharge request|DRE|(% style="width:500px" %)a request to close the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
14 +|Balancing request |BR|(% style="width:500px" %)a request to balance the cells;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
15 +|Battery cover |CVR|(% style="width:500px" %)a signal from the battery cover;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
16 +|CH contactor feedback |CCF|(% style="width:500px" %)a signal from charging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
17 +|CH/DCH contactor feedback |CDF|(% style="width:500px" %)a signal from charging/discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
18 +|Charge request |CRE|(% style="width:500px" %)a request to close the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
19 +|Charger connected |CON|(% style="width:500px" %)a signal indicating that charger is connected;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
20 +|Circuit breaker status |CBS|(% style="width:500px" %)status of protection disconnector;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
21 +|Close External 1 |CE1|(% style="width:500px" %)a request to close the External 1 discrete output (if assigned).|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
22 +|Close Main contactor |CMC|(% style="width:500px" %)a request to close the main contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
23 +|DCH contactor feedback |DCF|(% style="width:500px" %)a signal from discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
24 +|Discharge request |DRE|(% style="width:500px" %)a request to close the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
25 25  |Fuse 1|F1|(% style="width:500px" %)signal from fuse 1;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
26 26  |Fuse 2|F2|(% style="width:500px" %)signal from fuse 2;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
27 -|Fuse 3|F3|(% style="width:500px" %)signal from fuse 3;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
28 -|Inhibit charging|ICH|(% style="width:500px" %)a command to open the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
29 -|Inhibit discharging|IDC|(% style="width:500px" %)a command to open the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
30 -|Insulation status|INS|(% style="width:500px" %)a signal from an insulation monitoring device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
31 -|Interlock| |(% style="width:500px" %)a signal from interlock loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
32 -|Main contactor feedback|MCF|(% style="width:500px" %)a signal from main contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
33 -|PCH contactor feedback|PCF|(% style="width:500px" %)a signal from precharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
34 -|Power up/down request|PDN|(% style="width:500px" %)a request to power down the device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
27 +|Fuse 3 |F3|(% style="width:500px" %)signal from fuse 3;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
28 +|Inhibit charging |ICH|(% style="width:500px" %)a command to open the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
29 +|Inhibit discharging |IDC|(% style="width:500px" %)a command to open the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
30 +|Insulation status |INS|(% style="width:500px" %)a signal from an insulation monitoring device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
31 +|Interlock | |(% style="width:500px" %)a signal from interlock loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
32 +|Main contactor feedback |MCF|(% style="width:500px" %)a signal from main contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
33 +|PCH contactor feedback |PCF|(% style="width:500px" %)a signal from precharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
34 +|Power up/down request |PDN|(% style="width:500px" %)a request to power down the device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
35 35  |Precharge request|PRE|(% style="width:500px" %)a request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %) |(% style="width:137px" %) |(% style="width:137px" %)
36 36  
37 37  (% class="wikigeneratedid" %)
... ... @@ -44,30 +44,30 @@
44 44  (% style="width:1277px" %)
45 45  |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus**
46 46  |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3**
47 -|Allow charging|ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
48 -|Balancing 1|BA1|balancing the first series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
49 -|Balancing 2|BA2|balancing the second series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
47 +|Allow charging |ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
48 +|Balancing 1 |BA1|balancing the first series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
49 +|Balancing 2 |BA2|balancing the second series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
50 50  |Cell analysis|CEA| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
51 -|Charging current present|CCP|the presence of the charging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
52 -|Charging|CH|state of the charging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
51 +|Charging current present |CCP|the presence of the charging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
52 +|Charging |CH|state of the charging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
53 53  |Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
54 -|Cooler|COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
54 +|Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
55 55  |Crown EWS|EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
56 -|Discharging (AUX)|AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
57 -|Discharging current present|DCP|the presence of the discharging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
58 -|Discharging|DCH|state of the discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
59 -|External 1|EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
56 +|Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
57 +|Discharging current present |DCP|the presence of the discharging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
58 +|Discharging |DCH|state of the discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
59 +|External 1 |EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
60 60  |Heater (AUX)|HA| | |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
61 -|Heater|HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
62 -|High charging current|HCC|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
61 +|Heater |HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
62 +|High charging current |HCC|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
63 63  |Init|INI| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
64 -|Low SOC|LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
65 -|Main contactor|MCO|state of the main contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
66 -|Power down ACK|PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
67 -|Power up|PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
68 -|Precharging|PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
69 -|Ready to charge|RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
70 -|Ready to discharge|RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
64 +|Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
65 +|Main contactor |MCO|state of the main contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
66 +|Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %)
67 +|Power up |PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
68 +|Precharging |PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
69 +|Ready to charge |RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
70 +|Ready to discharge |RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
71 71  |Service reset|SR| |Yes~*~**| |Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
72 72  |Shutdown request (Combilift)|CSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
73 73  |Shutdown request (HYG/Spirit)|HSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %)
... ... @@ -112,7 +112,7 @@
112 112  |HVIL error|HE|breakage of high-voltage interlock current loop;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)
113 113  |HYG offline|HYG|connection with a HYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
114 114  |Insulation fault|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
115 -|Logic count error|LOG| | | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
115 +|Logic count error|LOG| | | |Yes| |(% style="width:142px" %) |(% style="width:134px" %)
116 116  |Logic offline|LOF|at least one of the Logic devices is offline;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
117 117  |Low temperature (CH)|LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
118 118  |Low temperature (DCH)|LDT|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)