Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -50,7 +50,7 @@ 50 50 |Cell analysis|CEA| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 51 51 |Charging current present |CCP|the presence of the charging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 52 52 |Charging |CH|state of the charging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 53 -|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes *|Yes|(% style="width:140px" %) |(% style="width:142px" %)53 +|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 54 54 |Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 55 55 |Crown EWS|EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 56 56 |Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -62,7 +62,7 @@ 62 62 |High charging current |HCC|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 63 63 |Init|INI| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 64 64 |Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 65 -|Main contactor |MCO|state of the main contactor;|Yes|Yes *|Yes|(% style="width:140px" %) |(% style="width:142px" %)65 +|Main contactor |MCO|state of the main contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 66 66 |Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 67 67 |Power up |PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 68 68 |Precharging |PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -73,6 +73,7 @@ 73 73 |Shutdown request (HYG/Spirit)|HSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 74 74 |Voltage too high for charging|ENV| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 75 75 76 + 76 76 (% class="wikigeneratedid" %) 77 77 ~* assignable to relay only 78 78 ... ... @@ -80,7 +80,7 @@ 80 80 ~** assignable to discrete input only 81 81 82 82 (% class="wikigeneratedid" %) 83 -~*~*~* state is indicative only and cannot be assigned to discrete output or relay.84 +~*~*~* those states are indicative only and cannot be assigned to discrete output or relay. 84 84 85 85 === List of errors === 86 86 ... ... @@ -102,16 +102,16 @@ 102 102 |DCH contactor cycles error |DCC|switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 103 103 |DCH contactor feedback error |DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 104 104 |FS error|FSE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 105 -|General error|GE| | |Yes *|Yes*|Yes|(% style="width:142px" %) |(% style="width:134px" %)106 +|General error|GE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 106 106 |High contactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 107 -|High humidity |HH|humidity of the battery is increased;| | 108 -|High Logic temperature |LHT|at least one of the Logic devices is overheated;| | 108 +|High humidity |HH|humidity of the battery is increased;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 +|High Logic temperature |LHT|at least one of the Logic devices is overheated;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 109 |High temperature (CH) |HCT|temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 110 110 |High temperature (DCH) |HDT|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 111 111 |High voltage fault |HVF|failure of high voltage measuring circuits;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 112 112 |HVIL error |HE|breakage of high-voltage interlock current loop;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 113 113 |HYG offline |HYG|connection with a HYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 114 -|Insulation fault|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 115 +|Insulation fault;|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 115 115 |Logic count error|LOG| | | | | |(% style="width:142px" %) |(% style="width:134px" %) 116 116 |Logic offline |LOF|at least one of the Logic devices is offline;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 117 117 |Low temperature (CH) |LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -135,7 +135,7 @@ 135 135 |Temperature sensor is shorted |TSS|some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 136 136 |Unallowable charging |UCH|charging the battery through the discharging contactor;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 137 137 |Undervoltage|UV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 138 -|Water |WA|there is water in the battery enclosure;|•| 139 +|Water |WA|there is water in the battery enclosure;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 139 139 |WDT reset |WDT|watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 140 140 141 - ~*signal can be assigned to a discrete output and relay.142 +