Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -73,7 +73,6 @@ 73 73 |Shutdown request (HYG/Spirit)|HSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 74 74 |Voltage too high for charging|ENV| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 75 75 76 - 77 77 (% class="wikigeneratedid" %) 78 78 ~* assignable to relay only 79 79 ... ... @@ -105,14 +105,14 @@ 105 105 |FS error|FSE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 106 106 |General error|GE| | |Yes*|Yes*|Yes|(% style="width:142px" %) |(% style="width:134px" %) 107 107 |High contactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 108 -|High humidity |HH|humidity of the battery is increased;| | Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)109 -|High Logic temperature |LHT|at least one of the Logic devices is overheated;| | Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)107 +|High humidity |HH|humidity of the battery is increased;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 108 +|High Logic temperature |LHT|at least one of the Logic devices is overheated;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 110 110 |High temperature (CH) |HCT|temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 111 111 |High temperature (DCH) |HDT|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 112 112 |High voltage fault |HVF|failure of high voltage measuring circuits;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 113 113 |HVIL error |HE|breakage of high-voltage interlock current loop;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 114 114 |HYG offline |HYG|connection with a HYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 115 -|Insulation fault ;|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)114 +|Insulation fault|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 116 116 |Logic count error|LOG| | | | | |(% style="width:142px" %) |(% style="width:134px" %) 117 117 |Logic offline |LOF|at least one of the Logic devices is offline;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 118 118 |Low temperature (CH) |LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -136,7 +136,7 @@ 136 136 |Temperature sensor is shorted |TSS|some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 137 137 |Unallowable charging |UCH|charging the battery through the discharging contactor;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 138 138 |Undervoltage|UV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 139 -|Water |WA|there is water in the battery enclosure;|•| Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)138 +|Water |WA|there is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 140 140 |WDT reset |WDT|watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 141 141 142 142 ~* signal can be assigned to a discrete output and relay.