... ... @@ -66,7 +66,7 @@
66 66  
67 67  
68 68  (% style="width:1177px" %)
69 -|Name |(% style="width:432px" %)Description|(% style="width:228px" %)Set up by|(% style="width:145px" %)Is Critical error?|(% style="width:145px" %)
69 +|**Name **|(% style="width:432px" %)**Description**|(% style="width:228px" %)**Set up by**|(% style="width:145px" %)**Is a Critical error?**|(% style="width:145px" %)
70 70  |Overcurrent|(% style="width:432px" %) |(% style="width:228px" %)Overcurrent protection|(% style="width:145px" %) |(% style="width:145px" %)
71 71  |Undervoltage|(% style="width:432px" %) |(% style="width:228px" %)Undervoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
72 72  |Overvoltage|(% style="width:432px" %) |(% style="width:228px" %)Overvoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
... ... @@ -106,11 +106,11 @@
106 106  |CH/DCH contactor feedback error |(% style="width:432px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %)
107 107  |Main contactor feedback error |(% style="width:432px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %)
108 108  |General error|(% style="width:432px" %) |(% style="width:228px" %)General error|(% style="width:145px" %) |(% style="width:145px" %)
109 -|High voltage fault |(% style="width:432px" %) failure of high voltage measuring circuits;|(% style="width:228px" %)High voltage controller|(% style="width:145px" %) |(% style="width:145px" %)
110 -|Power switch error |(% style="width:432px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
111 -|HVIL error |(% style="width:432px" %) breakage of high-voltage interlock current loop;|(% style="width:228px" %)HVIL protection|(% style="width:145px" %) |(% style="width:145px" %)
109 +|High voltage fault |(% style="width:432px" %) failure of high voltage measuring circuits;|(% style="width:228px" %)High voltage controller|(% style="width:145px" %)Yes|(% style="width:145px" %)
110 +|Power switch error |(% style="width:432px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:228px" %) |(% style="width:145px" %)Yes|(% style="width:145px" %)
111 +|HVIL error |(% style="width:432px" %) breakage of high-voltage interlock current loop;|(% style="width:228px" %)HVIL protection|(% style="width:145px" %)Yes|(% style="width:145px" %)
112 112  |Precharge error |(% style="width:432px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:228px" %)Precharge controller|(% style="width:145px" %) |(% style="width:145px" %)
113 -|Power fault |(% style="width:432px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
113 +|Power fault |(% style="width:432px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:228px" %) |(% style="width:145px" %)Yes|(% style="width:145px" %)
114 114  |Current limit error |(% style="width:432px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:228px" %)Charge current limit protection, Discharge current limit protection|(% style="width:145px" %) |(% style="width:145px" %)
115 115  
116 116