Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -89,11 +89,11 @@ 89 89 |Current sensor error |(% style="width:432px" %) error in the current sensor circuit;|(% style="width:228px" %)Current sensor protection|(% style="width:145px" %) |(% style="width:145px" %) 90 90 |CH contactor cycles error |(% style="width:432px" %) switching frequency of the charging contactor is too high;|(% style="width:228px" %)Charge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %) 91 91 |DCH contactor cycles error |(% style="width:432px" %) switching frequency of the discharging contactor is too high;|(% style="width:228px" %)Discharge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %) 92 -|Shunt offline |(% style="width:432px" %) connection with the shunt current sensor is lost;|(% style="width:228px" %) Shuntsensor (CAN bus)|(% style="width:145px" %) |(% style="width:145px" %)93 -|Shunt error |(% style="width:432px" %) internal error of the shunt current sensor;|(% style="width:228px" %) Shuntsensor (CAN bus)|(% style="width:145px" %) |(% style="width:145px" %)94 -|WDT reset |(% style="width:432px" %) watchdog timer reset the device;|(% style="width:228px" %) WDTreset protection|(% style="width:145px" %) |(% style="width:145px" %)95 -|No temperature sensors |(% style="width:432px" %) the device has no temperature sensors connected;|(% style="width:228px" %) Temperaturesensors protection|(% style="width:145px" %) |(% style="width:145px" %)96 -|Temperature sensor is shorted |(% style="width:432px" %) some temperature sensors are shorted;|(% style="width:228px" %) Temperaturesensors protection|(% style="width:145px" %) |(% style="width:145px" %)92 +|Shunt offline |(% style="width:432px" %) connection with the shunt current sensor is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 93 +|Shunt error |(% style="width:432px" %) internal error of the shunt current sensor;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 94 +|WDT reset |(% style="width:432px" %) watchdog timer reset the device;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 95 +|No temperature sensors |(% style="width:432px" %) the device has no temperature sensors connected;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 96 +|Temperature sensor is shorted |(% style="width:432px" %) some temperature sensors are shorted;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 97 97 |Spirit offline |(% style="width:432px" %) connection with a Spirit forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 98 98 |Low temperature (CH) |(% style="width:432px" %) temperature is too low for charging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 99 99 |High temperature (CH) |(% style="width:432px" %) temperature is too high for charging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %)