Last modified by Admin on 2025/03/03 15:20

From version 1.78
edited by Admin
on 2025/01/29 17:37
Change comment: There is no comment for this version
To version 1.72
edited by Admin
on 2025/01/29 17:30
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -65,52 +65,75 @@
65 65  Here is the list of error of BMS Main 3.
66 66  
67 67  
68 -(% style="width:1177px" %)
69 -|Name |(% style="width:432px" %)Description|(% style="width:228px" %)Set up by|(% style="width:145px" %)Used by|(% style="width:145px" %)
70 -|Overcurrent|(% style="width:432px" %) |(% style="width:228px" %)Overcurrent protection|(% style="width:145px" %) |(% style="width:145px" %)
71 -|Undervoltage|(% style="width:432px" %) |(% style="width:228px" %)Undervoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
72 -|Overvoltage|(% style="width:432px" %) |(% style="width:228px" %)Overvoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
73 -|Low temperature (DCH) |(% style="width:432px" %) temperature is too low for discharging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
74 -|High temperature (DCH) |(% style="width:432px" %) temperature is too high for discharging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
75 -|Battery cover error |(% style="width:432px" %) battery cover is open;|(% style="width:228px" %)Battery cover protection|(% style="width:145px" %) |(% style="width:145px" %)
76 -|High humidity |(% style="width:432px" %) humidity of the battery is increased;|(% style="width:228px" %)High humidity protection|(% style="width:145px" %) |(% style="width:145px" %)
77 -|Water |(% style="width:432px" %) there is water in the battery enclosure;|(% style="width:228px" %)Water protection|(% style="width:145px" %) |(% style="width:145px" %)
78 -|High Logic temperature |(% style="width:432px" %) at least one of the Logic devices is overheated;|(% style="width:228px" %)Logic high temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
79 -|Logic offline |(% style="width:432px" %) at least one of the Logic devices is offline;|(% style="width:228px" %)Logic offline protection|(% style="width:145px" %) |(% style="width:145px" %)
80 -|Critical error|(% style="width:432px" %) |(% style="width:228px" %)Critical error protection|(% style="width:145px" %) |(% style="width:145px" %)
81 -|Crown error |(% style="width:432px" %) connection with a Crown forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
82 -|Cell count error |(% style="width:432px" %) number of cells does not match the specified value;|(% style="width:228px" %)Cell count protection|(% style="width:145px" %) |(% style="width:145px" %)
83 -|HYG offline |(% style="width:432px" %) connection with a HYG forklift is lost;|(% style="width:228px" %)HYG Class I-III truck|(% style="width:145px" %) |(% style="width:145px" %)
84 -|Need acknowledge |(% style="width:432px" %) there is an unacknowledged error in Error journal;|(% style="width:228px" %)Error journal|(% style="width:145px" %) |(% style="width:145px" %)
85 -|Combilift offline |(% style="width:432px" %) connection with a Combilift forklift is lost;|(% style="width:228px" %)Combilift truck|(% style="width:145px" %) |(% style="width:145px" %)
86 -|Short circuit|(% style="width:432px" %) |(% style="width:228px" %)Short circuit protection|(% style="width:145px" %) |(% style="width:145px" %)
87 -|High contactor temperature|(% style="width:432px" %) |(% style="width:228px" %)High contactor temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
88 -|ADC error |(% style="width:432px" %) current cannot be measured;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
89 -|Current sensor error |(% style="width:432px" %) error in the current sensor circuit;|(% style="width:228px" %)Current sensor protection|(% style="width:145px" %) |(% style="width:145px" %)
90 -|CH contactor cycles error |(% style="width:432px" %) switching frequency of the charging contactor is too high;|(% style="width:228px" %)Charge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %)
91 -|DCH contactor cycles error |(% style="width:432px" %) switching frequency of the discharging contactor is too high;|(% style="width:228px" %)Discharge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %)
92 -|Shunt offline |(% style="width:432px" %) connection with the shunt current sensor is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
93 -|Shunt error |(% style="width:432px" %) internal error of the shunt current sensor;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
94 -|WDT reset |(% style="width:432px" %) watchdog timer reset the device;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
95 -|No temperature sensors |(% style="width:432px" %) the device has no temperature sensors connected;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
96 -|Temperature sensor is shorted |(% style="width:432px" %) some temperature sensors are shorted;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
97 -|Spirit offline |(% style="width:432px" %) connection with a Spirit forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
98 -|Low temperature (CH) |(% style="width:432px" %) temperature is too low for charging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
99 -|High temperature (CH) |(% style="width:432px" %) temperature is too high for charging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
100 -|Unallowable charging |(% style="width:432px" %) charging the battery through the discharging contactor;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
101 -|Stuck contactor;|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
102 -|CH contactor feedback error |(% style="width:432px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
103 -|DCH contactor feedback error |(% style="width:432px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
104 -|Insulation fault;|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
105 -|PCH contactor feedback error |(% style="width:432px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
106 -|CH/DCH contactor feedback error |(% style="width:432px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
107 -|Main contactor feedback error |(% style="width:432px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
108 -|General error|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
109 -|High voltage fault |(% style="width:432px" %) failure of high voltage measuring circuits;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
110 -|Power switch error |(% style="width:432px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
111 -|HVIL error |(% style="width:432px" %) breakage of high-voltage interlock current loop;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
112 -|Precharge error |(% style="width:432px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
113 -|Power fault |(% style="width:432px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
114 -|Current limit error |(% style="width:432px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
68 +|Name |Description|Set up by|Used by|
69 +|Overcurrent| | | |
70 +|Undervoltage| | | |
71 +|Overvoltage| | | |
72 +|Low temperature (DCH) | temperature is too low for discharging;| | |
73 +|High temperature (DCH) | temperature is too high for discharging;| | |
74 +|Battery cover error | battery cover is open;| | |
75 +|High humidity | humidity of the battery is increased;| | |
76 +|Water | there is water in the battery enclosure;| | |
77 +|High Logic temperature | at least one of the Logic devices is overheated;| | |
78 +|Logic offline | at least one of the Logic devices is offline;| | |
79 +|Critical error;| | | |
80 +|Crown error | connection with a Crown forklift is lost;| | |
81 +|Cell count error | number of cells does not match the specified value;| | |
82 +|HYG offline | connection with a HYG forklift is lost;| | |
83 +|Need acknowledge | there is an unacknowledged error in Error journal;| | |
84 +|Combilift offline | connection with a Combilift forklift is lost;| | |
85 +|Short circuit| | | |
86 +|High contactor temperature| | | |
87 +|ADC error | current cannot be measured;| | |
88 +|Current sensor error | error in the current sensor circuit;| | |
89 +|CH contactor cycles error | switching frequency of the charging contactor is too high;| | |
90 +|DCH contactor cycles error | switching frequency of the discharging contactor is too high;| | |
91 +|Shunt offline | connection with the shunt current sensor is lost;| | |
92 +|Shunt error | internal error of the shunt current sensor;| | |
93 +|WDT reset | watchdog timer reset the device;| | |
94 +|No temperature sensors | the device has no temperature sensors connected;| | |
95 +|Temperature sensor is shorted | some temperature sensors are shorted;| | |
96 +|Spirit offline | connection with a Spirit forklift is lost;| | |
97 +|Low temperature (CH) | temperature is too low for charging;| | |
98 +|High temperature (CH) | temperature is too high for charging;| | |
99 +|Unallowable charging | charging the battery through the discharging contactor;| | |
100 +|Stuck contactor;| | | |
101 +|CH contactor feedback error | the control signals for the charging contactor and the contactor feedback differ;| | |
102 +|DCH contactor feedback error | the control signals for the discharging contactor and the contactor feedback differ;| | |
103 +|Insulation fault;| | | |
104 +|PCH contactor feedback error | the control signals for the precharging contactor and the contactor feedback differ;| | |
105 +|CH/DCH contactor feedback error | the control signals for the charging/discharging contactor and the contactor feedback differ;| | |
106 +|Main contactor feedback error | the control signals for the main contactor and the contactor feedback differ;| | |
107 +|General error| | | |
108 +|High voltage fault | failure of high voltage measuring circuits;| | |
109 +|Power switch error | short circuit in contactor coil control circuit or power switch overheating;| | |
110 +|HVIL error | breakage of high-voltage interlock current loop;| | |
111 +|Precharge error | capacitive load pre-charge process did not end during the estimated time;| | |
112 +|Power fault | external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;| | |
113 +|Current limit error | charging or discharging current is more than limit calculated by Charge map or Discharge map.| | |
114 +| | | | |
115 +| | | | |
116 +| | | | |
117 +| | | | |
118 +| | | | |
119 +| | | | |
120 +| | | | |
121 +| | | | |
122 +| | | | |
123 +| | | | |
124 +| | | | |
125 +| | | | |
126 +| | | | |
127 +| | | | |
128 +| | | | |
129 +| | | | |
130 +| | | | |
131 +| | | | |
132 +| | | | |
133 +| | | | |
134 +| | | | |
135 +| | | | |
136 +| | | | |
137 +| | | | |
115 115  
116 116