Last modified by Admin on 2025/03/03 15:20

From version 1.70
edited by Admin
on 2025/01/29 17:26
Change comment: There is no comment for this version
To version 1.77
edited by Admin
on 2025/01/29 17:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -65,30 +65,52 @@
65 65  Here is the list of error of BMS Main 3.
66 66  
67 67  
68 -|Name |Description|Se| |
69 -| | | | |
70 -| | | | |
71 -| | | | |
72 -| | | | |
73 -| | | | |
74 -| | | | |
75 -| | | | |
76 -| | | | |
77 -| | | | |
78 -| | | | |
79 -| | | | |
80 -| | | | |
81 -| | | | |
82 -| | | | |
83 -| | | | |
84 -| | | | |
85 -| | | | |
86 -| | | | |
87 -| | | | |
88 -| | | | |
89 -| | | | |
90 -| | | | |
91 -| | | | |
92 -| | | | |
68 +(% style="width:1177px" %)
69 +|Name |(% style="width:432px" %)Description|(% style="width:228px" %)Set up by|(% style="width:145px" %)Used by|(% style="width:145px" %)
70 +|Overcurrent|(% style="width:432px" %) |(% style="width:228px" %)Overcurrent protection|(% style="width:145px" %) |(% style="width:145px" %)
71 +|Undervoltage|(% style="width:432px" %) |(% style="width:228px" %)Undervoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
72 +|Overvoltage|(% style="width:432px" %) |(% style="width:228px" %)Overvoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
73 +|Low temperature (DCH) |(% style="width:432px" %) temperature is too low for discharging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
74 +|High temperature (DCH) |(% style="width:432px" %) temperature is too high for discharging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
75 +|Battery cover error |(% style="width:432px" %) battery cover is open;|(% style="width:228px" %)Battery cover protection|(% style="width:145px" %) |(% style="width:145px" %)
76 +|High humidity |(% style="width:432px" %) humidity of the battery is increased;|(% style="width:228px" %)High humidity protection|(% style="width:145px" %) |(% style="width:145px" %)
77 +|Water |(% style="width:432px" %) there is water in the battery enclosure;|(% style="width:228px" %)Water protection|(% style="width:145px" %) |(% style="width:145px" %)
78 +|High Logic temperature |(% style="width:432px" %) at least one of the Logic devices is overheated;|(% style="width:228px" %)Logic high temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
79 +|Logic offline |(% style="width:432px" %) at least one of the Logic devices is offline;|(% style="width:228px" %)Logic offline protection|(% style="width:145px" %) |(% style="width:145px" %)
80 +|Critical error|(% style="width:432px" %) |(% style="width:228px" %)Critical error protection|(% style="width:145px" %) |(% style="width:145px" %)
81 +|Crown error |(% style="width:432px" %) connection with a Crown forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
82 +|Cell count error |(% style="width:432px" %) number of cells does not match the specified value;|(% style="width:228px" %)Cell count error|(% style="width:145px" %) |(% style="width:145px" %)
83 +|HYG offline |(% style="width:432px" %) connection with a HYG forklift is lost;|(% style="width:228px" %)HYG Class I-III truck|(% style="width:145px" %) |(% style="width:145px" %)
84 +|Need acknowledge |(% style="width:432px" %) there is an unacknowledged error in Error journal;|(% style="width:228px" %)Error journal|(% style="width:145px" %) |(% style="width:145px" %)
85 +|Combilift offline |(% style="width:432px" %) connection with a Combilift forklift is lost;|(% style="width:228px" %)Combilift truck|(% style="width:145px" %) |(% style="width:145px" %)
86 +|Short circuit|(% style="width:432px" %) |(% style="width:228px" %)Short circuit protection|(% style="width:145px" %) |(% style="width:145px" %)
87 +|High contactor temperature|(% style="width:432px" %) |(% style="width:228px" %)High contactor temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
88 +|ADC error |(% style="width:432px" %) current cannot be measured;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
89 +|Current sensor error |(% style="width:432px" %) error in the current sensor circuit;|(% style="width:228px" %)Current se|(% style="width:145px" %) |(% style="width:145px" %)
90 +|CH contactor cycles error |(% style="width:432px" %) switching frequency of the charging contactor is too high;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
91 +|DCH contactor cycles error |(% style="width:432px" %) switching frequency of the discharging contactor is too high;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
92 +|Shunt offline |(% style="width:432px" %) connection with the shunt current sensor is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
93 +|Shunt error |(% style="width:432px" %) internal error of the shunt current sensor;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
94 +|WDT reset |(% style="width:432px" %) watchdog timer reset the device;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
95 +|No temperature sensors |(% style="width:432px" %) the device has no temperature sensors connected;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
96 +|Temperature sensor is shorted |(% style="width:432px" %) some temperature sensors are shorted;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
97 +|Spirit offline |(% style="width:432px" %) connection with a Spirit forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
98 +|Low temperature (CH) |(% style="width:432px" %) temperature is too low for charging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
99 +|High temperature (CH) |(% style="width:432px" %) temperature is too high for charging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
100 +|Unallowable charging |(% style="width:432px" %) charging the battery through the discharging contactor;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
101 +|Stuck contactor;|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
102 +|CH contactor feedback error |(% style="width:432px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
103 +|DCH contactor feedback error |(% style="width:432px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
104 +|Insulation fault;|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
105 +|PCH contactor feedback error |(% style="width:432px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
106 +|CH/DCH contactor feedback error |(% style="width:432px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
107 +|Main contactor feedback error |(% style="width:432px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
108 +|General error|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
109 +|High voltage fault |(% style="width:432px" %) failure of high voltage measuring circuits;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
110 +|Power switch error |(% style="width:432px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
111 +|HVIL error |(% style="width:432px" %) breakage of high-voltage interlock current loop;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
112 +|Precharge error |(% style="width:432px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
113 +|Power fault |(% style="width:432px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
114 +|Current limit error |(% style="width:432px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
93 93  
94 94