Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -48,25 +48,29 @@ 48 48 49 49 Here is the list of available input signals of BMS Main 3. 50 50 51 -|Name|Description|Where is used| | 52 -|Battery cover| | | | 53 -|Charger connected| | | | 54 -|Power up/down request| | | | 55 -|Inhibit charging| | | | 56 -|Inhibit discharging| | | | 57 -| | | | | 58 -| | | | | 59 -| | | | | 60 -| | | | | 61 -| | | | | 62 -| | | | | 63 -| | | | | 64 -| | | | | 65 -| | | | | 66 -| | | | | 67 -| | | | | 68 -| | | | | 69 -| | | | | 70 -| | | | | 51 +(% style="width:1227px" %) 52 +|(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% colspan="1" rowspan="2" style="width:321px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)**Where is used**|(% colspan="3" rowspan="1" style="width:160px" %)**Settable via** 53 +|(% style="width:112px" %)**Discrete input**|(% style="width:159px" %)**CAN**|(% style="width:159px" %)**Modbus** 54 +|(% style="width:216px" %)No input |(% style="width:321px" %) input is not used;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 55 +|(% style="width:216px" %)Battery cover |(% style="width:321px" %) a signal from the battery cover;|(% style="width:258px" %)Battery cover protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 56 +|(% style="width:216px" %)Charger connected |(% style="width:321px" %) a signal indicating that charger is connected;|(% style="width:258px" %)Charge controller, Discharge controller|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 57 +|(% style="width:216px" %)Power up/down request |(% style="width:321px" %) a request to power down the device;|(% style="width:258px" %)Power down|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 58 +|(% style="width:216px" %)Inhibit charging |(% style="width:321px" %) a command to open the charging contactor;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 59 +|(% style="width:216px" %)Inhibit discharging |(% style="width:321px" %) a command to open the discharging contactor;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 60 +|(% style="width:216px" %)CH contactor feedback |(% style="width:321px" %) a signal from charging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 61 +|(% style="width:216px" %)DCH contactor feedback |(% style="width:321px" %) a signal from discharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 62 +|(% style="width:216px" %)Insulation status |(% style="width:321px" %) a signal from an insulation monitoring device;|(% style="width:258px" %)Insulation protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 63 +|(% style="width:216px" %)Charge request |(% style="width:321px" %) a request to close the charging contactor;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 64 +|(% style="width:216px" %)Precharge request |(% style="width:321px" %) a request to close the precharging contactor;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 65 +|(% style="width:216px" %)Discharge request |(% style="width:321px" %) a request to close the discharging contactor;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 66 +|(% style="width:216px" %)PCH contactor feedback |(% style="width:321px" %) a signal from precharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 67 +|(% style="width:216px" %)CH/DCH contactor feedback |(% style="width:321px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 68 +|(% style="width:216px" %)Main contactor feedback |(% style="width:321px" %) a signal from main contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 69 +|(% style="width:216px" %)Interlock |(% style="width:321px" %) a signal from interlock loop;|(% style="width:258px" %)Interlock protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 70 +|(% style="width:216px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:321px" %) signals from fuses;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 71 +|(% style="width:216px" %)Circuit breaker status |(% style="width:321px" %) status of protection disconnector;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 72 +|(% style="width:216px" %)Balancing request |(% style="width:321px" %) a request to balance the cells;|(% style="width:258px" %)Cell balance|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 73 +|(% style="width:216px" %)Close Main contactor |(% style="width:321px" %) a request to close the main contactor;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 74 +|(% style="width:216px" %)Close External 1 |(% style="width:321px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %) 71 71 72 72