Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -41,20 +41,20 @@ 41 41 |Low SOC | a signal corresponding the low SOC of the battery;|(% style="width:258px" %)Low SOC signal controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 42 42 |High charging current | charging current is high;|(% style="width:258px" %)High charging signal controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (if corresponding External equipment is online)|(% style="width:159px" %) 43 43 |Main contactor | state of the main contactor;|(% style="width:258px" %)Main contactor controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 44 -|Charging | state of the charging contactor;|(% style="width:258px" %)Charge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 45 -|Allow charging | a signal for a charger to start charging;|(% style="width:258px" %)Charge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 44 +|Charging | state of the charging contactor;|(% style="width:258px" %)Charge controller, Charging/Discharging controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 45 +|Allow charging | a signal for a charger to start charging;|(% style="width:258px" %)Charge controller, Charging/Discharging controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 46 46 |Charging current present | the presence of the charging current;|(% style="width:258px" %)Charging status controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 47 47 |Precharging | state of the precharging contactor;|(% style="width:258px" %)Precharge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 48 -|Discharging | state of the discharging contactor;|(% style="width:258px" %)Discharge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 48 +|Discharging | state of the discharging contactor;|(% style="width:258px" %)Discharge controller, Charging/Discharging controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 49 49 |Discharging current present | the presence of the discharging current;|(% style="width:258px" %)Discharging status controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 50 50 |Discharging (AUX) | state of the auxiliary discharging contactor;|(% style="width:258px" %)Discharging (AUX) controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 51 -|Power down ACK | an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:258px" %) Contactorfeedback protection|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)52 -|Charging/discharging -state of the charging/discharging contactor;||(% style="width:258px" %)Contactorfeedback protection|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)53 -|Heater | a command to turn on a heater;|(% style="width:258px" %) Contactorfeedback protection|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)54 -|Cooler | a command to turn on a cooler;|(% style="width:258px" %) Interlock protection|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)55 -|Balancing 1 | balancing the first series of cells;|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 56 -|Balancing 2 | balancing the second series of cells;|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 57 -|Ready to charge | the battery is ready to be charged;|(% style="width:258px" %)C ell balance|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)•|(% style="width:159px" %)51 +|Power down ACK | an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:258px" %)Power down controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 52 +|Charging/discharging|state of the charging/discharging contactor;|(% style="width:258px" %)Charging/Discharging controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 53 +|Heater | a command to turn on a heater;|(% style="width:258px" %)Heater controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 54 +|Cooler | a command to turn on a cooler;|(% style="width:258px" %)Cooler controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 55 +|Balancing 1 | balancing the first series of cells;|(% style="width:258px" %)Series balancing controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 56 +|Balancing 2 | balancing the second series of cells;|(% style="width:258px" %)Series balancing controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 57 +|Ready to charge | the battery is ready to be charged;|(% style="width:258px" %)Charging status controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)•|(% style="width:159px" %) 58 58 |Ready to discharge | the battery is ready to be discharged;|(% style="width:258px" %)Main contactor|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 59 59 |Power up | an indication of BMS power status;|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 60 60 |General error | state of the configurable (general) error;|(% style="width:258px" %) |(% style="width:163px" %) |(% style="width:126px" %) |(% style="width:159px" %) |(% style="width:159px" %)