Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -37,7 +37,7 @@ 37 37 38 38 (% style="width:1227px" %) 39 39 |(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% colspan="1" rowspan="2" style="width:321px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)**Where is used**|(% colspan="4" rowspan="1" style="width:258px" %)**Shared via** 40 -|(% style="width:163px" %)**Discrete output**|(% style="width:126px" %)** Relay**|(% style="width:159px" %)**CAN**|(% style="width:159px" %)**Modbus**40 +|(% style="width:163px" %)**Discrete output**|(% style="width:126px" %)**Switch**|(% style="width:159px" %)**CAN**|(% style="width:159px" %)**Modbus** 41 41 |Low SOC | a signal corresponding the low SOC of the battery;|(% style="width:258px" %)Low SOC signal controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 42 42 |High charging current | charging current is high;|(% style="width:258px" %)High charging signal controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (if corresponding External equipment is online)|(% style="width:159px" %) 43 43 |Main contactor | state of the main contactor;|(% style="width:258px" %)Main contactor controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) ... ... @@ -48,8 +48,8 @@ 48 48 |Discharging | state of the discharging contactor;|(% style="width:258px" %)Discharge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 49 49 |Discharging current present | the presence of the discharging current;|(% style="width:258px" %)Discharging status controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 50 50 |Discharging (AUX) | state of the auxiliary discharging contactor;|(% style="width:258px" %)Discharging (AUX) controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 51 -|Power down ACK | an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:258px" %) Contactorfeedback protection|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)52 -|Charging/discharging -state of the charging/discharging contactor;||(% style="width:258px" %)Contactorfeedback protection|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)51 +|Power down ACK | an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:258px" %)Power down controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 52 +|Charging/discharging|state of the charging/discharging contactor;|(% style="width:258px" %)Charging/Discharging contoller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 53 53 |Heater | a command to turn on a heater;|(% style="width:258px" %)Contactor feedback protection|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 54 54 |Cooler | a command to turn on a cooler;|(% style="width:258px" %)Interlock protection|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 55 55 |Balancing 1 | balancing the first series of cells;|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)