Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -38,14 +38,14 @@ 38 38 (% style="width:1227px" %) 39 39 |(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% colspan="1" rowspan="2" style="width:321px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)**Where is used**|(% colspan="3" rowspan="1" style="width:160px" %)**Shared via** 40 40 |(% style="width:112px" %)**Discrete output**|(% style="width:159px" %)**CAN**|(% style="width:159px" %)**Modbus** 41 -|Low SOC | a signal corresponding the low SOC of the battery;|(% style="width:258px" %)Low SOC signalcontroller|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)42 -|High charging current | charging current is high;|(% style="width:258px" %) Highchargingsignalcontroller|(% style="width:112px" %)•|(% style="width:159px" %)• (if corresponding External equipment is online)|(% style="width:159px" %)43 -|Main contactor | state of the main contactor;|(% style="width:258px" %) Main contactorcontroller|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)44 -|Charging | state of the charging contactor;|(% style="width:258px" %) Chargecontroller|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)45 -|Allow charging | a signal for a charger to start charging;|(% style="width:258px" %) Chargecontroller|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)46 -|Charging current present | the presence of the charging current;|(% style="width:258px" %)C hargecontroller|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)47 -|Precharging | state of the precharging contactor;|(% style="width:258px" %) Prechargeontroller|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)48 -|Discharging | state of the discharging contactor;|(% style="width:258px" %) Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)41 +|Low SOC | a signal corresponding the low SOC of the battery;|(% style="width:258px" %)Low SOC controller|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 42 +|High charging current | charging current is high;|(% style="width:258px" %)Charge controller, Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %)• (if corresponding External equipment is online)|(% style="width:159px" %) 43 +|Main contactor | state of the main contactor;|(% style="width:258px" %)Power down|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 44 +|Charging | state of the charging contactor;|(% style="width:258px" %) |(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 45 +|Allow charging | a signal for a charger to start charging;|(% style="width:258px" %) |(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 46 +|Charging current present | the presence of the charging current;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 47 +|Precharging | state of the precharging contactor;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 48 +|Discharging | state of the discharging contactor;|(% style="width:258px" %)Insulation protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 49 49 |Discharging current present | the presence of the discharging current;|(% style="width:258px" %)Charge controller|(% style="width:112px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 50 50 |Discharging (AUX) | state of the auxiliary discharging contactor;|(% style="width:258px" %)Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 51 51 |Power down ACK | an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)