Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -52,7 +52,7 @@ 52 52 |(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% colspan="1" rowspan="2" style="width:321px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)**Where is used**|(% colspan="3" rowspan="1" style="width:160px" %)**Settable via** 53 53 |(% style="width:112px" %)**Discrete input**|(% style="width:159px" %)**CAN**|(% style="width:159px" %)**Modbus** 54 54 |(% style="width:216px" %)Battery cover |(% style="width:321px" %) a signal from the battery cover;|(% style="width:258px" %)Battery cover protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 55 -|(% style="width:216px" %)Charger connected |(% style="width:321px" %) a signal indicating that charger is connected;|(% style="width:258px" %)Charge controller, Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %)• (in External equipment)|(% style="width:159px" %) 55 +|(% style="width:216px" %)Charger connected |(% style="width:321px" %) a signal indicating that charger is connected;|(% style="width:258px" %)Charge controller, Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %)• (if corresponding External equipment is online)|(% style="width:159px" %) 56 56 |(% style="width:216px" %)Power up/down request |(% style="width:321px" %) a request to power down the device;|(% style="width:258px" %)Power down|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 57 57 |(% style="width:216px" %)Inhibit charging |(% style="width:321px" %) a command to open the charging contactor;|(% style="width:258px" %) |(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 58 58 |(% style="width:216px" %)Inhibit discharging |(% style="width:321px" %) a command to open the discharging contactor;|(% style="width:258px" %) |(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) ... ... @@ -59,8 +59,8 @@ 59 59 |(% style="width:216px" %)CH contactor feedback |(% style="width:321px" %) a signal from charging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 60 60 |(% style="width:216px" %)DCH contactor feedback |(% style="width:321px" %) a signal from discharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 61 61 |(% style="width:216px" %)Insulation status |(% style="width:321px" %) a signal from an insulation monitoring device;|(% style="width:258px" %)Insulation protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 62 -|(% style="width:216px" %)Charge request |(% style="width:321px" %) a request to close the charging contactor;|(% style="width:258px" %)Charge controller|(% style="width:112px" %)•|(% style="width:159px" %)•|(% style="width:159px" %) 63 -|(% style="width:216px" %)Discharge request |(% style="width:321px" %) a request to close the discharging contactor;|(% style="width:258px" %)Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %)•|(% style="width:159px" %) 62 +|(% style="width:216px" %)Charge request |(% style="width:321px" %) a request to close the charging contactor;|(% style="width:258px" %)Charge controller|(% style="width:112px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 63 +|(% style="width:216px" %)Discharge request |(% style="width:321px" %) a request to close the discharging contactor;|(% style="width:258px" %)Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 64 64 |(% style="width:216px" %)PCH contactor feedback |(% style="width:321px" %) a signal from precharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 65 65 |(% style="width:216px" %)CH/DCH contactor feedback |(% style="width:321px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 66 66 |(% style="width:216px" %)Main contactor feedback |(% style="width:321px" %) a signal from main contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) ... ... @@ -68,7 +68,9 @@ 68 68 |(% style="width:216px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:321px" %) signals from fuses;|(% style="width:258px" %) |(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 69 69 |(% style="width:216px" %)Circuit breaker status |(% style="width:321px" %) status of protection disconnector;|(% style="width:258px" %) |(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 70 70 |(% style="width:216px" %)Balancing request |(% style="width:321px" %) a request to balance the cells;|(% style="width:258px" %)Cell balance|(% style="width:112px" %)•|(% style="width:159px" %)•|(% style="width:159px" %) 71 -|(% style="width:216px" %)Close Main contactor |(% style="width:321px" %) a request to close the main contactor;|(% style="width:258px" %)Main contactor|(% style="width:112px" %)•|(% style="width:159px" %)•|(% style="width:159px" %) 71 +|(% style="width:216px" %)Close Main contactor |(% style="width:321px" %) a request to close the main contactor;|(% style="width:258px" %)Main contactor|(% style="width:112px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 72 72 |(% style="width:216px" %)Close External 1 |(% style="width:321px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:258px" %) |(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 73 73 74 - 74 +=== List of supported input signals === 75 + 76 +Here is the list of available input signals of BMS Main 3.