Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -59,8 +59,8 @@ 59 59 |(% style="width:216px" %)CH contactor feedback |(% style="width:321px" %) a signal from charging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 60 60 |(% style="width:216px" %)DCH contactor feedback |(% style="width:321px" %) a signal from discharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 61 61 |(% style="width:216px" %)Insulation status |(% style="width:321px" %) a signal from an insulation monitoring device;|(% style="width:258px" %)Insulation protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 62 -|(% style="width:216px" %)Charge request |(% style="width:321px" %) a request to close the charging contactor;|(% style="width:258px" %)Charge controller|(% style="width:112px" %)•|(% style="width:159px" %) •|(% style="width:159px" %)63 -|(% style="width:216px" %)Discharge request |(% style="width:321px" %) a request to close the discharging contactor;|(% style="width:258px" %)Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %) •|(% style="width:159px" %)62 +|(% style="width:216px" %)Charge request |(% style="width:321px" %) a request to close the charging contactor;|(% style="width:258px" %)Charge controller|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 63 +|(% style="width:216px" %)Discharge request |(% style="width:321px" %) a request to close the discharging contactor;|(% style="width:258px" %)Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 64 64 |(% style="width:216px" %)PCH contactor feedback |(% style="width:321px" %) a signal from precharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 65 65 |(% style="width:216px" %)CH/DCH contactor feedback |(% style="width:321px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 66 66 |(% style="width:216px" %)Main contactor feedback |(% style="width:321px" %) a signal from main contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)