... ... @@ -51,8 +51,8 @@
51 51  (% style="width:1227px" %)
52 52  |(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% colspan="1" rowspan="2" style="width:321px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)**Where is used**|(% colspan="3" rowspan="1" style="width:160px" %)**Settable via**
53 53  |(% style="width:112px" %)**Discrete input**|(% style="width:159px" %)**CAN**|(% style="width:159px" %)**Modbus**
54 -|(% style="width:216px" %)No input |(% style="width:321px" %) input is not used;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
55 -|(% style="width:216px" %)Battery cover |(% style="width:321px" %) a signal from the battery cover;|(% style="width:258px" %)Battery cover protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
54 +|(% style="width:216px" %)No input |(% style="width:321px" %) input is not used;|(% style="width:258px" %) |(% style="width:112px" %)|(% style="width:159px" %) |(% style="width:159px" %)
55 +|(% style="width:216px" %)Battery cover |(% style="width:321px" %) a signal from the battery cover;|(% style="width:258px" %)Battery cover protection|(% style="width:112px" %)|(% style="width:159px" %) |(% style="width:159px" %)
56 56  |(% style="width:216px" %)Charger connected |(% style="width:321px" %) a signal indicating that charger is connected;|(% style="width:258px" %)Charge controller, Discharge controller|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
57 57  |(% style="width:216px" %)Power up/down request |(% style="width:321px" %) a request to power down the device;|(% style="width:258px" %)Power down|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
58 58  |(% style="width:216px" %)Inhibit charging |(% style="width:321px" %) a command to open the charging contactor;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
... ... @@ -61,8 +61,7 @@
61 61  |(% style="width:216px" %)DCH contactor feedback |(% style="width:321px" %) a signal from discharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
62 62  |(% style="width:216px" %)Insulation status |(% style="width:321px" %) a signal from an insulation monitoring device;|(% style="width:258px" %)Insulation protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
63 63  |(% style="width:216px" %)Charge request |(% style="width:321px" %) a request to close the charging contactor;|(% style="width:258px" %)Charge controller|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
64 -|(% style="width:216px" %)Precharge request |(% style="width:321px" %) a request to close the precharging contactor;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
65 -|(% style="width:216px" %)Discharge request |(% style="width:321px" %) a request to close the discharging contactor;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
64 +|(% style="width:216px" %)Discharge request |(% style="width:321px" %) a request to close the discharging contactor;|(% style="width:258px" %)Discharge controller|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
66 66  |(% style="width:216px" %)PCH contactor feedback |(% style="width:321px" %) a signal from precharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
67 67  |(% style="width:216px" %)CH/DCH contactor feedback |(% style="width:321px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
68 68  |(% style="width:216px" %)Main contactor feedback |(% style="width:321px" %) a signal from main contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
... ... @@ -70,7 +70,7 @@
70 70  |(% style="width:216px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:321px" %) signals from fuses;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
71 71  |(% style="width:216px" %)Circuit breaker status |(% style="width:321px" %) status of protection disconnector;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
72 72  |(% style="width:216px" %)Balancing request |(% style="width:321px" %) a request to balance the cells;|(% style="width:258px" %)Cell balance|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
73 -|(% style="width:216px" %)Close Main contactor |(% style="width:321px" %) a request to close the main contactor;|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
72 +|(% style="width:216px" %)Close Main contactor |(% style="width:321px" %) a request to close the main contactor;|(% style="width:258px" %)Main contactor|(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
74 74  |(% style="width:216px" %)Close External 1 |(% style="width:321px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:258px" %) |(% style="width:112px" %) |(% style="width:159px" %) |(% style="width:159px" %)
75 75  
76 76