Changes for page Обзор программы
Last modified by Admin on 2026/04/27 12:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -122,7 +122,7 @@ 122 122 123 123 [[image:1766059864519-882.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="430"]] 124 124 125 -The structure of the monitor window's sections and menus is similar to the Web interface and is described in the [[documentation for the BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.WebHome]].125 +The structure of the monitor window's sections and menus is similar to the Web interface and is described in the [[BMS Main 2.1 documentation>>doc:Battery management systems.BMS Main 2\.1.WebHome]]. 126 126 127 127 == BMS Logic 2.0 == 128 128 ... ... @@ -130,23 +130,23 @@ 130 130 131 131 The BMS Logic 2.0 setup and verification window is divided into two areas. 132 132 133 -The upper partcontains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 12).133 +**The upper area** contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 12). 134 134 135 -* The **"Volts"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds ,respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. Thisallowsforeasy trackingofthe voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"Capture"** button,youcanmemorize the current voltage values of all cells ifyouneedto compare several BMS Logic devices with each other.136 -* The temperature sensor readings in the **"**°C**"** field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the **"Temperature sensor"** field below. 137 -* The **"**Discharge**"** row contains flags indicating whether balancing is enabled for the corresponding cell. 138 -* The **"**Board temperature**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting. 139 -* The **"**Temperature sensor**"** field allows you to set the model of the thermistor used for temperature measurement. 140 -* The **"**Voltage difference**"** field indicates the difference between the minimum and maximum cell voltages. 141 -* The **"**Temperature difference**"** field indicates the difference between the minimum and maximum temperatures. 135 +* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other. 136 +* The temperature sensor readings in the **"**//°C//**"** field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the **"**Temperature sensor**"** field below. 137 +* The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell. 138 +* The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting. 139 +* The **"**//Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement. 140 +* The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages. 141 +* The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures. 142 142 143 -The **Commands** section contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:143 +The **Commands **section contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement: 144 144 145 -* **Discharge all cells**–Command to balance all cells.146 -* **Yellow voltage difference**–Threshold value for cell voltage measurement error for the yellow level, V.147 -* **Red voltage difference**–Threshold value for cell voltage measurement error for the red level, V.148 -* **Yellow temperature difference**–Threshold value for cell temperature measurement error for the yellow level, °C.149 -* **Red temperature difference**–Threshold value for cell temperature measurement error for the red level, °C.145 +* Discharge all cells – command to balance all cells. 146 +* Yellow voltage difference – threshold value for cell voltage measurement error for the yellow level, V. 147 +* Red voltage difference – threshold value for cell voltage measurement error for the red level, V. 148 +* Yellow temperature difference – threshold value for cell temperature measurement error for the yellow level, °C. 149 +* Red temperature difference – threshold value for cell temperature measurement error for the red level, °C. 150 150 151 151 == BMS Logic 12/18/RET == 152 152