Last modified by Admin on 2026/04/27 12:30

From version 8.2
edited by Admin
on 2025/12/23 09:21
Change comment: There is no comment for this version
To version 8.11
edited by Admin
on 2025/12/23 09:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -64,7 +64,7 @@
64 64  * Log in – open the re-authorization window.
65 65  * Change password – open the window to change the password for the current user.
66 66  * SD card – open the window for interacting with the installed SD card.
67 -* Update firmware – open the window for updating the device firmware via Unified Monitor. The update process via Unified Monitor is described in the documentation for the corresponding device (e.g., BMS Mini S). An SD card must be installed to perform an update in this mode.
67 +* Update firmware – open the window for updating the device firmware via Unified Monitor. The update process via Unified Monitor is described in the documentation for the corresponding device (e.g., [[BMS Mini S>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]]). An SD card must be installed to perform an update in this mode.
68 68  * Reboot – device restart.
69 69  * Go to bootloader – switch the device to bootloader mode.
70 70  
... ... @@ -103,88 +103,91 @@
103 103  
104 104  [[image:1766055020158-734.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="221" width="600"]]
105 105  
106 -Above the column of parameter groups are the following buttons:
106 +Above the column of parameter groups there are the following buttons:
107 107  
108 -* Reload – Reloads all board parameters.
109 -* Save – Saves all changed parameters simultaneously.
110 -* **Export** – Exports settings from the device to a text file.
111 -* **Import** – Imports settings from a text file into the device. After importing the settings, click the **Save** button.
108 +* Reload – reread all board parameters;
109 +* Save – save all changed parameters simultaneously;
110 +* Export – export settings from the device to a text file;
111 +* Import – import settings from a text file into the device. After importing the settings, click the Save button.
112 112  
113 113  
114 114  
115 -**В нижней области** приводится история действий с устройством.
115 +**The bottom area** displays the history of actions performed with the device.
116 116  
117 117  [[image:1766054531745-297.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="73" width="600"]]
118 118  
119 119  == BMS Main 2.1 ==
120 120  
121 -Монитор BMS Main 2.1 позволяет подключиться к устройству через шину CAN. Для этого следует выбрать соответствующий CAN адаптер и выбрать устройство из списка (Systec, PEAK или Marathon) или задать номер COM-порта (BMS USB-CAN).
121 +The BMS Main 2.1 monitor allows you to connect the device via the CAN bus. To do this, select the corresponding CAN adapter and choose a device from the list (Systec, PEAK, or Marathon) or specify the COM port number (BMS USB-CAN).
122 122  
123 123  [[image:1766059864519-882.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="430"]]
124 124  
125 -Структура разделов и меню окна монитора аналогична Web интерфейсу и описана в [[документации на BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.WebHome]].
125 +The structure of the monitor window's sections and menus is similar to the Web interface and is described in the [[BMS Main 2.1 documentation>>doc:Battery management systems.BMS Main 2\.1.WebHome]].
126 126  
127 127  == BMS Logic 2.0 ==
128 128  
129 -[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]]Окно настройки и проверки BMS Logic 2.0 разделено на две области.
129 +[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]]
130 130  
131 -В **верхней части **содержится информация о всех ячейках, подключенных к устройству. Ключевые параметры отображены по вертикали относительно соответствующей ячейки Cell 1 - Cell 12.
131 +The BMS Logic 2.0 setup and verification window is divided into two areas.
132 132  
133 -* Поле "//Volts" //отображает напряжение ячейки в вольтах. Минимальное и максимальное напряжение среди всех ячеек выделяется синим и красным фоном соответственно. Над цифровым полем располагается графическое представление напряжения ячейки. Ниже располагаются поля для указания действительного напряжения ячейки. Разница между заданным и измеренным напряжениями ячейки показывается в строке Difference и выделяется цветом в зависимости от степени различия. Таким образом можно легко отследить погрешность измерения напряжения у устройства BMS Logic. Пороговые значения погрешностей задаются в разделе Commands в нижней части окна. Также с помощью кнопки "Capture" можно запомнить текущее значение напряжений всех ячеек в случае, если требуется сравнить несколько устройств BMS Logic между собой.
134 -* Аналогичным образом отображаются показания температурных датчиков в поле "//°C//" – имеется возможность запомнить показания температур и отслеживать разницу измереных и заданных показаний в реальном времени. Модель используемого температурного датчика задается в поле "Temperature sensor" ниже.
135 -* Строка "//Discharge//" содержит флаги включения балансировки соответствующей ячейки.
136 -* Поле "//Board temperature//" показывает температуру платы BMS Logic. В полях справа задается температура, измеренная внешним термометром (первое поле), а также максимально допустимая погрешность измерения (второе поле). Текущая погрешность измерения показывается в третьем поле с цветовым выделением.
137 -* Поле "//Temperature sensor//" позволяет установить модель используемого для измерения температуры термистора.
138 -* Поле "//Voltage difference//" указывает на разницу между минимальной и максимальной напряжениями ячеек.
139 -* Поле "//Temperature difference//" указывает на разницу между минимальной и максимальной температурами.
133 +**The upper area** contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 12).
140 140  
141 -Секция **Commands **содержит поля для передачи команд устройству, а также пороговые значения погрешностей для измерения напряжения и температуры:
135 +* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other.
136 +* The temperature sensor readings in the **"**//°C//**"** field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the **"**Temperature sensor**"** field below.
137 +* The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell.
138 +* The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting.
139 +* The **"**//Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement.
140 +* The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages.
141 +* The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures.
142 142  
143 -* Discharge all cells – команда на балансировку всех ячеек;
144 -* Yellow voltage difference – пороговое значение погрешности измерения напряжения ячейки для желтого уровня, В;
145 -* Red voltage difference – пороговое значение погрешности измерения напряжения ячейки для красного уровня, В;
146 -* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для желтого уровня, В;
147 -* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для красного уровня, В.
143 +The **Commands **section contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:
148 148  
145 +* Discharge all cells – command to balance all cells.
146 +* Yellow voltage difference – threshold value for cell voltage measurement error for the yellow level, V.
147 +* Red voltage difference – threshold value for cell voltage measurement error for the red level, V.
148 +* Yellow temperature difference – threshold value for cell temperature measurement error for the yellow level, °C.
149 +* Red temperature difference – threshold value for cell temperature measurement error for the red level, °C.
150 +
149 149  == BMS Logic 12/18/RET ==
150 150  
151 -Процесс подключения и настройки устройств BMS Logic 12/18/RET/12S описан в документации на соответствующее устройство (например, [[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).
153 +The process of connecting and configuring the BMS Logic 12/18/RET/12S devices is described in the documentation for the corresponding device (for example, [[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).
152 152  
153 -[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]]Окно настройки и проверки устрйоств BMS Logic разделено на три области.
155 +[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]]
154 154  
157 +The BMS Logic device setup and verification window is divided into three areas.
155 155  
156 -Секция **Info **содержит в себе информацию об устройстве:
159 +The **Info** section contains device information:
157 157  
158 -* Hardware version версия аппаратного обеспечения;
159 -* Software version версия программного обеспечения;
160 -* Cell count количетво подключенных на данный момент ячеек;
161 -* Serial number серийный номер устройства. Сериный номер сохраняется единоразово во время производства платы;
162 -* Balancing resistance номинал балансировочных резисторов, Ом. Задается единоразово во время производства платы;
163 -* Address уникальный адрес устройства. Каждое устройство BMS Logic, подключенное контроллеру BMS Main, должно иметь уникальный адрес.
161 +* **Hardware version** Hardware version.
162 +* **Software version** Software version.
163 +* **Cell count** Number of cells currently connected.
164 +* **Serial number** Device serial number. The serial number is saved once during board production.
165 +* **Balancing resistance** Balancing resistor value, Ohms. Set once during board production.
166 +* **Address** Unique device address. Each BMS Logic device connected to a BMS Main controller must have a unique address.
164 164  
165 -Секция **Measurements **содержит в себе информацию о всех ячейках, подключенных к устройству. Ключевые параметры отображены по вертикали относительно соответствующей ячейки Cell 1 - Cell 18.
168 +The **Measurements** section contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 18).
166 166  
167 -* Поле "//Volts" //отображает напряжение ячейки в вольтах. Минимальное и максимальное напряжение среди всех ячеек выделяется синим и красным фоном соответственно. Над цифровым полем располагается графическое представление напряжения ячейки. Ниже располагаются поля для указания действительного напряжения ячейки. Разница между заданным и измеренным напряжениями ячейки показывается в строке Difference и выделяется цветом в зависимости от степени различия. Таким образом можно легко отследить погрешность измерения напряжения у устройства BMS Logic. Пороговые значения погрешностей задаются в разделе Commands в нижней части окна. Также с помощью кнопки "Capture" можно запомнить текущее значение напряжений всех ячеек в случае, если требуется сравнить несколько устройств BMS Logic между собой.
168 -* Аналогичным образом отображаются показания температурных датчиков для каждой ячейки в поле "//°C//" – имеется возможность запомнить показания температур и отслеживать разницу измереных и заданных показаний в реальном времени. Модель используемого температурного датчика задается в поле "Temperature sensor" ниже.
169 -* Строка "//Inputs (C0-C18)//" отображает статус подключения соответствующей измерительной линии напряжения.
170 -* Строка "//Discharge//" содержит флаги включения балансировки соответствующей ячейки.
171 -* Строка "//uOhm//" не используется.
172 -* Поле "//Board temperature//" показывает температуру платы BMS Logic. В полях справа задается температура, измеренная внешним термометром (первое поле), а также максимально допустимая погрешность измерения (второе поле). Текущая погрешность измерения показывается в третьем поле с цветовым выделением.
173 -* Поле "//Temperature sensor//" позволяет установить модель используемого для измерения температуры термистора.
174 -* Поле "//Voltage difference//" указывает на разницу между минимальной и максимальной напряжениями ячеек.
175 -* Поле "//Temperature difference//" указывает на разницу между минимальной и максимальной температурами.
170 +* The **"Volts"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds, respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"Difference"** row and is color-coded depending on the degree of discrepancy. This allows for easy tracking of the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"Commands"** section at the bottom of the window. Also, using the **"Capture"** button, you can memorize the current voltage values of all cells if you need to compare several BMS Logic devices with each other.
171 +* The temperature sensor readings for each cell in the **"°C"** field are displayed similarly there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the **"Temperature sensor"** field below.
172 +* The **"Inputs (C0-C18)"** row displays the connection status of the corresponding voltage measurement line.
173 +* The **"Discharge"** row contains flags indicating whether balancing is enabled for the corresponding cell.
174 +* The **"uOhm"** row is not used.
175 +* The **"Board temperature"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting.
176 +* The **"Temperature sensor"** field allows you to set the model of the thermistor used for temperature measurement.
177 +* The **"Voltage difference"** field indicates the difference between the minimum and maximum cell voltages.
178 +* The **"Temperature difference"** field indicates the difference between the minimum and maximum temperatures.
176 176  
177 -Секция **Commands **содержит поля для передачи команд устройству, а также пороговые значения погрешностей для измерения напряжения и температуры:
180 +The **Commands** section contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:
178 178  
179 -* Discharge all cells команда на балансировку всех ячеек;
180 -* Sleep перевод устройства в режим сна;
181 -* Wake up перевод устройства из режима сна в рабочий режим;
182 -* Bootloader перевод устроства в режим загрузчика;
183 -* Yellow voltage difference пороговое значение погрешности измерения напряжения ячейки для желтого уровня, В;
184 -* Red voltage difference пороговое значение погрешности измерения напряжения ячейки для красного уровня, В;
185 -* Yellow temperature difference пороговое значение погрешности измерения температуры ячейки для желтого уровня, В;
186 -* Yellow temperature difference пороговое значение погрешности измерения температуры ячейки для красного уровня, В;
187 -* Строка "Resistance calculation" не используется.
182 +* **Discharge all cells** Command to balance all cells.
183 +* **Sleep** Puts the device into sleep mode.
184 +* **Wake up** Takes the device out of sleep mode into operational mode.
185 +* **Bootloader** Puts the device into bootloader mode.
186 +* **Yellow voltage difference** Threshold value for cell voltage measurement error for the yellow level, V.
187 +* **Red voltage difference** Threshold value for cell voltage measurement error for the red level, V.
188 +* **Yellow temperature difference** Threshold value for cell temperature measurement error for the yellow level, °C.
189 +* **Red temperature difference** Threshold value for cell temperature measurement error for the red level, °C.
190 +* The **"Resistance calculation"** row is not used.
188 188  
189 189  == BMS Display ==
190 190