Changes for page Обзор программы
Last modified by Admin on 2026/04/27 12:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -163,11 +163,11 @@ 163 163 * Cell count – number of cells currently connected. 164 164 * Serial number – device serial number. The serial number is saved once during board production. 165 165 * Balancing resistance – balancing resistor value, Ohms. Set once during board production. 166 -* Address – unique device address. Each BMS Logic device connected to a BMS Main controller must have a unique address.166 +* Address – Unique device address. Each BMS Logic device connected to a BMS Main controller must have a unique address. 167 167 168 168 The **Measurements** area contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 18). 169 169 170 -* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helpsto easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button,it is possibletomemorize the current voltage values of all cells ifitisneededto compare several BMS Logic devices with each other.170 +* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds, respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This allows for easy tracking of the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, you can memorize the current voltage values of all cells if you need to compare several BMS Logic devices with each other. 171 171 * The temperature sensor readings for each cell in the "//°C//" field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the "Temperature sensor" field below. 172 172 * The **"**//Inputs (C0-C18)//**"** row displays the connection status of the corresponding voltage measurement line. 173 173 * The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell. ... ... @@ -179,29 +179,29 @@ 179 179 180 180 The **Commands** area contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement: 181 181 182 -* Discharge all cells – command to balance all cells.183 -* Sleep – put the device into sleep mode.184 -* Wake up – take the device out of sleep mode into operational mode.185 -* Bootloader – put the device into bootloader mode.186 -* Yellow voltage difference – threshold value for cell voltage measurement error for the yellow level, V.187 -* Red voltage difference – threshold value for cell voltage measurement error for the red level, V.188 -* Yellow temperature difference – threshold value for cell temperature measurement error for the yellow level, °C.189 -* Red temperature difference – threshold value for cell temperature measurement error for the red level, °C.182 +* Discharge all cells – Command to balance all cells. 183 +* Sleep – Puts the device into sleep mode. 184 +* Wake up – Takes the device out of sleep mode into operational mode. 185 +* Bootloader – Puts the device into bootloader mode. 186 +* Yellow voltage difference – Threshold value for cell voltage measurement error for the yellow level, V. 187 +* Red voltage difference – Threshold value for cell voltage measurement error for the red level, V. 188 +* Yellow temperature difference – Threshold value for cell temperature measurement error for the yellow level, °C. 189 +* Red temperature difference – Threshold value for cell temperature measurement error for the red level, °C. 190 190 * The "Resistance calculation" row is not used. 191 191 192 192 == BMS Display == 193 193 194 - TheBMS Displaymonitorwindowis described in the[[BMS Displaydocumentation>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]].194 +Окно монитора BMS Display описано в [[документации на BMS Display>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]]. 195 195 196 196 == BMS Indication == 197 197 198 - TheBMS Indicationmonitorwindowis described in the[[BMS Indicationdocumentation>>doc:Battery management systems.BMS Indication.3\. Configuration.WebHome]].198 +Окно монитора BMS Indication описано в [[документации на BMS Indication>>doc:Battery management systems.BMS Indication.3\. Configuration.WebHome]]. 199 199 200 200 == Updater == 201 201 202 - TheupdatermoduleallowsupdatingthefirmwareofBMS Mini, BMS Mini S, BMS Main X, BMS Main 2.1, BMS Logic 12/18/RET/12S, BMS Display,andBMS IMDdevices through the bootloader.202 +Модуль обновления через загрузчик позволяет обновлять встроенное ПО устройств BMS Mini, BMS Mini S, BMS Main X, BMS Main 2.1, BMS Logic 12/18/RET/12S, BMS Display, BMS IMD. 203 203 204 - Thebootloaderupdateprocessisdescribedinthe"FirmwareUpdate"sectionofthedocumentationforthecorrespondingdevice(forexample,BMS Main 2.1).204 +Процесс обновления через загрузчик описан в разделе "Обновление ВПО" в документации на соответствующее устройство (например, [[BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]). 205 205 206 206 == Unified bootloader == 207 207