Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -64,7 +64,7 @@ 64 64 * Log in – open the re-authorization window. 65 65 * Change password – open the window to change the password for the current user. 66 66 * SD card – open the window for interacting with the installed SD card. 67 -* Update firmware – open the window for updating the device firmware via Unified Monitor. The update process via Unified Monitor is described in the documentation for the corresponding device (e.g., [[BMS Mini S>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]]). An SD card must be installed to perform an update in this mode.67 +* Update firmware – open the window for updating the device firmware via Unified Monitor. The update process via Unified Monitor is described in the documentation for the corresponding device (e.g., BMS Mini S). An SD card must be installed to perform an update in this mode. 68 68 * Reboot – device restart. 69 69 * Go to bootloader – switch the device to bootloader mode. 70 70 ... ... @@ -103,95 +103,92 @@ 103 103 104 104 [[image:1766055020158-734.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="221" width="600"]] 105 105 106 -Above the column of parameter groups thereare the following buttons:106 +Above the column of parameter groups are the following buttons: 107 107 108 -* Reload – reread all board parameters;109 -* Save – save all changed parameters simultaneously;110 -* Export – export settings from the device to a text file;111 -* Import – import settings from a text file into the device. After importing the settings, click the Save button.108 +* Reload – Reloads all board parameters. 109 +* Save – Saves all changed parameters simultaneously. 110 +* **Export** – Exports settings from the device to a text file. 111 +* **Import** – Imports settings from a text file into the device. After importing the settings, click the **Save** button. 112 112 113 113 114 114 115 -** Thebottomarea**displaysthehistoryofactions performed with the device.115 +**В нижней области** приводится история действий с устройством. 116 116 117 117 [[image:1766054531745-297.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="73" width="600"]] 118 118 119 119 == BMS Main 2.1 == 120 120 121 - TheBMS Main 2.1monitorallowsyoutoconnectthedevice via theCANbus.Todothis,selectthecorrespondingCANadapterandchooseadevicefromthe list(Systec, PEAK,orMarathon)orspecifytheCOMport number(BMS USB-CAN).121 +Монитор BMS Main 2.1 позволяет подключиться к устройству через шину CAN. Для этого следует выбрать соответствующий CAN адаптер и выбрать устройство из списка (Systec, PEAK или Marathon) или задать номер COM-порта (BMS USB-CAN). 122 122 123 123 [[image:1766059864519-882.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="430"]] 124 124 125 - Thestructureofthemonitorwindow'ssectionsand menus is similar to theWebinterfaceandisdescribedin the[[BMS Main 2.1documentation>>doc:Battery management systems.BMS Main 2\.1.WebHome]].125 +Структура разделов и меню окна монитора аналогична Web интерфейсу и описана в [[документации на BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.WebHome]]. 126 126 127 127 == BMS Logic 2.0 == 128 128 129 -[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]] 129 +[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]]Окно настройки и проверки BMS Logic 2.0 разделено на две области. 130 130 131 - TheBMSLogic2.0setupandverificationwindowisdividedintotwoareas.131 +В **верхней части **содержится информация о всех ячейках, подключенных к устройству. Ключевые параметры отображены по вертикали относительно соответствующей ячейки Cell 1 - Cell 12. 132 132 133 -**The upper area** contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 12). 133 +* Поле "//Volts" //отображает напряжение ячейки в вольтах. Минимальное и максимальное напряжение среди всех ячеек выделяется синим и красным фоном соответственно. Над цифровым полем располагается графическое представление напряжения ячейки. Ниже располагаются поля для указания действительного напряжения ячейки. Разница между заданным и измеренным напряжениями ячейки показывается в строке Difference и выделяется цветом в зависимости от степени различия. Таким образом можно легко отследить погрешность измерения напряжения у устройства BMS Logic. Пороговые значения погрешностей задаются в разделе Commands в нижней части окна. Также с помощью кнопки "Capture" можно запомнить текущее значение напряжений всех ячеек в случае, если требуется сравнить несколько устройств BMS Logic между собой. 134 +* Аналогичным образом отображаются показания температурных датчиков в поле "//°C//" – имеется возможность запомнить показания температур и отслеживать разницу измереных и заданных показаний в реальном времени. Модель используемого температурного датчика задается в поле "Temperature sensor" ниже. 135 +* Строка "//Discharge//" содержит флаги включения балансировки соответствующей ячейки. 136 +* Поле "//Board temperature//" показывает температуру платы BMS Logic. В полях справа задается температура, измеренная внешним термометром (первое поле), а также максимально допустимая погрешность измерения (второе поле). Текущая погрешность измерения показывается в третьем поле с цветовым выделением. 137 +* Поле "//Temperature sensor//" позволяет установить модель используемого для измерения температуры термистора. 138 +* Поле "//Voltage difference//" указывает на разницу между минимальной и максимальной напряжениями ячеек. 139 +* Поле "//Temperature difference//" указывает на разницу между минимальной и максимальной температурами. 134 134 135 -* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other. 136 -* The temperature sensor readings in the **"**//°C//**"** field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the **"**Temperature sensor**"** field below. 137 -* The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell. 138 -* The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting. 139 -* The **"**//Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement. 140 -* The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages. 141 -* The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures. 141 +Секция **Commands **содержит поля для передачи команд устройству, а также пороговые значения погрешностей для измерения напряжения и температуры: 142 142 143 -The **Commands **area contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement: 143 +* Discharge all cells – команда на балансировку всех ячеек; 144 +* Yellow voltage difference – пороговое значение погрешности измерения напряжения ячейки для желтого уровня, В; 145 +* Red voltage difference – пороговое значение погрешности измерения напряжения ячейки для красного уровня, В; 146 +* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для желтого уровня, В; 147 +* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для красного уровня, В. 144 144 145 -* Discharge all cells – command to balance all cells. 146 -* Yellow voltage difference – threshold value for cell voltage measurement error for the yellow level, V. 147 -* Red voltage difference – threshold value for cell voltage measurement error for the red level, V. 148 -* Yellow temperature difference – threshold value for cell temperature measurement error for the yellow level, °C. 149 -* Red temperature difference – threshold value for cell temperature measurement error for the red level, °C. 150 - 151 151 == BMS Logic 12/18/RET == 152 152 153 - Theprocessofconnectingandconfiguring theBMS Logic 12/18/RET/12Sdevicesisdescribedinthedocumentationfor the corresponding device(for example,[[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).151 +Процесс подключения и настройки устройств BMS Logic 12/18/RET/12S описан в документации на соответствующее устройство (например, [[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]). 154 154 155 -[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]] 153 +[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]]Окно настройки и проверки устрйоств BMS Logic разделено на три области. 156 156 157 -The BMS Logic device setup and verification window is divided into three areas. 158 158 159 - The**Info**areacontainsdeviceinformation:156 +Секция **Info **содержит в себе информацию об устройстве: 160 160 161 -* Hardware version; 162 -* Software version; 163 -* Cell count –numberofcellscurrentlyconnected.164 -* Serial number –deviceserialnumber.Theserialnumberissavedonceduringboard production.165 -* Balancing resistance –balancingresistorvalue,Ohms.Setonceduringboardproduction.166 -* Address –uniquedeviceaddress.EachBMS Logicdeviceconnectedto aBMS Maincontrollermusthavea unique address.158 +* Hardware version – версия аппаратного обеспечения; 159 +* Software version – версия программного обеспечения; 160 +* Cell count – количетво подключенных на данный момент ячеек; 161 +* Serial number – серийный номер устройства. Сериный номер сохраняется единоразово во время производства платы; 162 +* Balancing resistance – номинал балансировочных резисторов, Ом. Задается единоразово во время производства платы; 163 +* Address – уникальный адрес устройства. Каждое устройство BMS Logic, подключенное контроллеру BMS Main, должно иметь уникальный адрес. 167 167 168 - The**Measurements**areacontainsinformationaboutallcellsconnectedtothedevice.Keyparametersaredisplayedverticallyrelativetothecorresponding cell (Cell 1 - Cell 18).165 +Секция **Measurements **содержит в себе информацию о всех ячейках, подключенных к устройству. Ключевые параметры отображены по вертикали относительно соответствующей ячейки Cell 1 - Cell 18. 169 169 170 -* The **"**//Volts//**"** fielddisplaysthecellvoltage in volts.Theminimumandmaximumvoltageamongallcellsarehighlightedwithblueand red backgrounds respectively.Agraphicalrepresentationofthecellvoltageis located above the numeric field.Belowarefieldsforspecifyingtheactual(reference) cell voltage.Thedifferencebetweenthereferenceandmeasuredcellvoltagesisshown in the **"**Difference**"** rowandiscolor-codeddependingonthedegreeof discrepancy.ThishelpstoeasilytrackthevoltagemeasurementerroroftheBMS Logicdevice.Theerrorthresholdvaluesaresetin the **"**Commands**"** sectionatthebottomof the window.Also,usingthe **"**Capture**"** button,itispossibletomemorizethecurrentvoltagevaluesofallcellsifitis needed to compare severalBMS Logicdeviceswith each other.171 -* Thetemperaturesensorreadingsforeachcellinthe"//°C//"fieldare displayed similarly–thereisanoptiontomemorizetemperaturereadingsandmonitorthedifferencebetweenmeasuredand reference readings in real time.Themodelofthetemperaturesensorusedis set in the"Temperature sensor"fieldbelow.172 -* The **"**//Inputs (C0-C18)//**"** rowdisplaystheconnectionstatusofthecorresponding voltage measurement line.173 -* The **"**//Discharge//**"** rowcontainsflagsindicatingwhetherbalancingis enabled for the corresponding cell.174 -* The **"**//uOhm//**"** rowisnot used.175 -* The **"**//Board temperature//**"** fieldshowsthetemperatureof theBMS Logicboard.Thefieldstotherightareforenteringthe temperature measured by an external thermometer(firstfield)andthemaximumallowablemeasurementerror(secondfield).Thecurrentmeasurementerrorisshowninthethirdfield with color highlighting.176 -* The **"**//Temperature sensor//**"** fieldallowsyoutosetthemodelofthe thermistor used for temperature measurement.177 -* The **"**//Voltage difference//**"** fieldindicatesthedifferencebetweentheminimumandmaximumcell voltages.178 -* The **"**//Temperature difference//**"** fieldindicatesthedifferencebetweentheminimumandmaximum temperatures.167 +* Поле "//Volts" //отображает напряжение ячейки в вольтах. Минимальное и максимальное напряжение среди всех ячеек выделяется синим и красным фоном соответственно. Над цифровым полем располагается графическое представление напряжения ячейки. Ниже располагаются поля для указания действительного напряжения ячейки. Разница между заданным и измеренным напряжениями ячейки показывается в строке Difference и выделяется цветом в зависимости от степени различия. Таким образом можно легко отследить погрешность измерения напряжения у устройства BMS Logic. Пороговые значения погрешностей задаются в разделе Commands в нижней части окна. Также с помощью кнопки "Capture" можно запомнить текущее значение напряжений всех ячеек в случае, если требуется сравнить несколько устройств BMS Logic между собой. 168 +* Аналогичным образом отображаются показания температурных датчиков для каждой ячейки в поле "//°C//" – имеется возможность запомнить показания температур и отслеживать разницу измереных и заданных показаний в реальном времени. Модель используемого температурного датчика задается в поле "Temperature sensor" ниже. 169 +* Строка "//Inputs (C0-C18)//" отображает статус подключения соответствующей измерительной линии напряжения. 170 +* Строка "//Discharge//" содержит флаги включения балансировки соответствующей ячейки. 171 +* Строка "//uOhm//" не используется. 172 +* Поле "//Board temperature//" показывает температуру платы BMS Logic. В полях справа задается температура, измеренная внешним термометром (первое поле), а также максимально допустимая погрешность измерения (второе поле). Текущая погрешность измерения показывается в третьем поле с цветовым выделением. 173 +* Поле "//Temperature sensor//" позволяет установить модель используемого для измерения температуры термистора. 174 +* Поле "//Voltage difference//" указывает на разницу между минимальной и максимальной напряжениями ячеек. 175 +* Поле "//Temperature difference//" указывает на разницу между минимальной и максимальной температурами. 179 179 180 - The**Commands**areacontainsfieldsforsendingcommands to the device,aswellaserrorthresholdsforvoltageandtemperaturemeasurement:177 +Секция **Commands **содержит поля для передачи команд устройству, а также пороговые значения погрешностей для измерения напряжения и температуры: 181 181 182 -* Discharge all cells –commandtobalanceallcells.183 -* Sleep –putthedeviceintosleep mode.184 -* Wake up –takethedeviceoutofsleepmodeinto operational mode.185 -* Bootloader –putthedeviceintobootloader mode.186 -* Yellow voltage difference –thresholdvalueforcellvoltagemeasurementerrorforthe yellow level,V.187 -* Red voltage difference –thresholdvalueforcellvoltagemeasurementerrorforthe red level,V.188 -* Yellow temperature difference –thresholdvalueforcelltemperaturemeasurementerrorforthe yellow level,°C.189 -* Redtemperature difference–thresholdvalueforcelltemperaturemeasurementerrorforthe red level,°C.190 -* The"Resistance calculation"rowisnotused.179 +* Discharge all cells – команда на балансировку всех ячеек; 180 +* Sleep – перевод устройства в режим сна; 181 +* Wake up – перевод устройства из режима сна в рабочий режим; 182 +* Bootloader – перевод устроства в режим загрузчика; 183 +* Yellow voltage difference – пороговое значение погрешности измерения напряжения ячейки для желтого уровня, В; 184 +* Red voltage difference – пороговое значение погрешности измерения напряжения ячейки для красного уровня, В; 185 +* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для желтого уровня, В; 186 +* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для красного уровня, В; 187 +* Строка "Resistance calculation" – не используется. 191 191 192 192 == BMS Display == 193 193 194 - TheBMS Displaymonitorwindowis described in the[[BMS Displaydocumentation>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]].191 +Окно монитора BMS Display описано в [[документации на BMS Display>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]]. 195 195 196 196 == BMS Indication == 197 197