163 163  * Cell count – number of cells currently connected.
164 164  * Serial number – device serial number. The serial number is saved once during board production.
165 165  * Balancing resistance – balancing resistor value, Ohms. Set once during board production.
166 -* Address – unique device address. Each BMS Logic device connected to a BMS Main controller must have a unique address.
166 +* Address – Unique device address. Each BMS Logic device connected to a BMS Main controller must have a unique address.
167 167  
168 168  The **Measurements** area contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 18).
169 169  
170 -* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other.
170 +* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds, respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This allows for easy tracking of the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, you can memorize the current voltage values of all cells if you need to compare several BMS Logic devices with each other.
171 171  * The temperature sensor readings for each cell in the "//°C//" field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the "Temperature sensor" field below.
172 172  * The **"**//Inputs (C0-C18)//**"** row displays the connection status of the corresponding voltage measurement line.
173 173  * The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell.