Changes for page Обзор программы
Last modified by Admin on 2026/04/27 12:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -140,7 +140,7 @@ 140 140 * The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages. 141 141 * The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures. 142 142 143 -The **Commands ** areacontains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:143 +The **Commands **section contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement: 144 144 145 145 * Discharge all cells – command to balance all cells. 146 146 * Yellow voltage difference – threshold value for cell voltage measurement error for the yellow level, V. ... ... @@ -156,38 +156,38 @@ 156 156 157 157 The BMS Logic device setup and verification window is divided into three areas. 158 158 159 -The **Info** areacontains device information:159 +The **Info** section contains device information: 160 160 161 -* Hardware version ;162 -* Software version ;163 -* Cell count – number of cells currently connected.164 -* Serial number – device serial number. The serial number is saved once during board production.165 -* Balancing resistance – balancing resistor value, Ohms. Set once during board production.166 -* Address – unique device address. Each BMS Logic device connected to a BMS Main controller must have a unique address.161 +* Hardware version – Hardware version. 162 +* Software version – Software version. 163 +* Cell count – Number of cells currently connected. 164 +* Serial number – Device serial number. The serial number is saved once during board production. 165 +* Balancing resistance – Balancing resistor value, Ohms. Set once during board production. 166 +* Address – Unique device address. Each BMS Logic device connected to a BMS Main controller must have a unique address. 167 167 168 -The **Measurements** areacontains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 18).168 +The **Measurements** section contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 18). 169 169 170 -* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helpsto easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button,it is possibletomemorize the current voltage values of all cells ifitisneededto compare several BMS Logic devices with each other.170 +* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds, respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This allows for easy tracking of the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, you can memorize the current voltage values of all cells if you need to compare several BMS Logic devices with each other. 171 171 * The temperature sensor readings for each cell in the "//°C//" field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the "Temperature sensor" field below. 172 172 * The **"**//Inputs (C0-C18)//**"** row displays the connection status of the corresponding voltage measurement line. 173 173 * The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell. 174 174 * The **"**//uOhm//**"** row is not used. 175 175 * The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting. 176 -* The **"** //Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement.177 -* The **"** //Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages.178 -* The **"** //Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures.176 +* The **"**Temperature sensor**"** field allows you to set the model of the thermistor used for temperature measurement. 177 +* The **"**Voltage difference**"** field indicates the difference between the minimum and maximum cell voltages. 178 +* The **"**Temperature difference**"** field indicates the difference between the minimum and maximum temperatures. 179 179 180 -The **Commands** areacontains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:180 +The **Commands** section contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement: 181 181 182 -* Discharge all cells – Command to balance all cells. 183 -* Sleep – Puts the device into sleep mode. 184 -* Wake up – Takes the device out of sleep mode into operational mode. 185 -* Bootloader – Puts the device into bootloader mode. 186 -* Yellow voltage difference – Threshold value for cell voltage measurement error for the yellow level, V. 187 -* Red voltage difference – Threshold value for cell voltage measurement error for the red level, V. 188 -* Yellow temperature difference – Threshold value for cell temperature measurement error for the yellow level, °C. 189 -* Red temperature difference – Threshold value for cell temperature measurement error for the red level, °C. 190 -* The "Resistance calculation" row is not used. 182 +* **Discharge all cells** – Command to balance all cells. 183 +* **Sleep** – Puts the device into sleep mode. 184 +* **Wake up** – Takes the device out of sleep mode into operational mode. 185 +* **Bootloader** – Puts the device into bootloader mode. 186 +* **Yellow voltage difference** – Threshold value for cell voltage measurement error for the yellow level, V. 187 +* **Red voltage difference** – Threshold value for cell voltage measurement error for the red level, V. 188 +* **Yellow temperature difference** – Threshold value for cell temperature measurement error for the yellow level, °C. 189 +* **Red temperature difference** – Threshold value for cell temperature measurement error for the red level, °C. 190 +* The **"Resistance calculation"** row is not used. 191 191 192 192 == BMS Display == 193 193