... ... @@ -122,32 +122,30 @@
122 122  
123 123  [[image:1766059864519-882.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="430"]]
124 124  
125 -The structure of the monitor window's sections and menus is similar to the Web interface and is described in the [[BMS Main 2.1 documentation>>doc:Battery management systems.BMS Main 2\.1.WebHome]].
125 +The structure of the monitor window's sections and menus is similar to the Web interface and is described in the documentation for the BMS Main 2.1.
126 126  
127 127  == BMS Logic 2.0 ==
128 128  
129 -[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]]
129 +[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]]Окно настройки и проверки BMS Logic 2.0 разделено на две области.
130 130  
131 -The BMS Logic 2.0 setup and verification window is divided into two areas.
131 +В **верхней части **содержится информация о всех ячейках, подключенных к устройству. Ключевые параметры отображены по вертикали относительно соответствующей ячейки Cell 1 - Cell 12.
132 132  
133 -**The upper area** contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 12).
133 +* Поле "//Volts" //отображает напряжение ячейки в вольтах. Минимальное и максимальное напряжение среди всех ячеек выделяется синим и красным фоном соответственно. Над цифровым полем располагается графическое представление напряжения ячейки. Ниже располагаются поля для указания действительного напряжения ячейки. Разница между заданным и измеренным напряжениями ячейки показывается в строке Difference и выделяется цветом в зависимости от степени различия. Таким образом можно легко отследить погрешность измерения напряжения у устройства BMS Logic. Пороговые значения погрешностей задаются в разделе Commands в нижней части окна. Также с помощью кнопки "Capture" можно запомнить текущее значение напряжений всех ячеек в случае, если требуется сравнить несколько устройств BMS Logic между собой.
134 +* Аналогичным образом отображаются показания температурных датчиков в поле "//°C//" – имеется возможность запомнить показания температур и отслеживать разницу измереных и заданных показаний в реальном времени. Модель используемого температурного датчика задается в поле "Temperature sensor" ниже.
135 +* Строка "//Discharge//" содержит флаги включения балансировки соответствующей ячейки.
136 +* Поле "//Board temperature//" показывает температуру платы BMS Logic. В полях справа задается температура, измеренная внешним термометром (первое поле), а также максимально допустимая погрешность измерения (второе поле). Текущая погрешность измерения показывается в третьем поле с цветовым выделением.
137 +* Поле "//Temperature sensor//" позволяет установить модель используемого для измерения температуры термистора.
138 +* Поле "//Voltage difference//" указывает на разницу между минимальной и максимальной напряжениями ячеек.
139 +* Поле "//Temperature difference//" указывает на разницу между минимальной и максимальной температурами.
134 134  
135 -* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other.
136 -* The temperature sensor readings in the **"**//°C//**"** field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the **"**Temperature sensor**"** field below.
137 -* The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell.
138 -* The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting.
139 -* The **"**//Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement.
140 -* The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages.
141 -* The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures.
141 +Секция **Commands **содержит поля для передачи команд устройству, а также пороговые значения погрешностей для измерения напряжения и температуры:
142 142  
143 -The **Commands **section contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:
143 +* Discharge all cells – команда на балансировку всех ячеек;
144 +* Yellow voltage difference – пороговое значение погрешности измерения напряжения ячейки для желтого уровня, В;
145 +* Red voltage difference – пороговое значение погрешности измерения напряжения ячейки для красного уровня, В;
146 +* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для желтого уровня, В;
147 +* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для красного уровня, В.
144 144  
145 -* Discharge all cells – command to balance all cells.
146 -* Yellow voltage difference – threshold value for cell voltage measurement error for the yellow level, V.
147 -* Red voltage difference – threshold value for cell voltage measurement error for the red level, V.
148 -* Yellow temperature difference – threshold value for cell temperature measurement error for the yellow level, °C.
149 -* Red temperature difference – threshold value for cell temperature measurement error for the red level, °C.
150 -
151 151  == BMS Logic 12/18/RET ==
152 152  
153 153  Процесс подключения и настройки устройств BMS Logic 12/18/RET/12S описан в документации на соответствующее устройство (например, [[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).