... ... @@ -140,7 +140,7 @@
140 140  * The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages.
141 141  * The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures.
142 142  
143 -The **Commands **section contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:
143 +The **Commands **area contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:
144 144  
145 145  * Discharge all cells – command to balance all cells.
146 146  * Yellow voltage difference – threshold value for cell voltage measurement error for the yellow level, V.
... ... @@ -150,76 +150,79 @@
150 150  
151 151  == BMS Logic 12/18/RET ==
152 152  
153 -Процесс подключения и настройки устройств BMS Logic 12/18/RET/12S описан в документации на соответствующее устройство (например, [[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).
153 +The process of connecting and configuring the BMS Logic 12/18/RET/12S devices is described in the documentation for the corresponding device (for example, [[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).
154 154  
155 -[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]]Окно настройки и проверки устрйоств BMS Logic разделено на три области.
155 +[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]]
156 156  
157 +The BMS Logic device setup and verification window is divided into three areas.
157 157  
158 -Секция **Info **содержит в себе информацию об устройстве:
159 +The **Info** area contains device information:
159 159  
160 -* Hardware version – версия аппаратного обеспечения;
161 -* Software version – версия программного обеспечения;
162 -* Cell count количетво подключенных на данный момент ячеек;
163 -* Serial number серийный номер устройства. Сериный номер сохраняется единоразово во время производства платы;
164 -* Balancing resistance номинал балансировочных резисторов, Ом. Задается единоразово во время производства платы;
165 -* Address уникальный адрес устройства. Каждое устройство BMS Logic, подключенное контроллеру BMS Main, должно иметь уникальный адрес.
161 +* Hardware version;
162 +* Software version;
163 +* Cell count number of cells currently connected.
164 +* Serial number device serial number. The serial number is saved once during board production.
165 +* Balancing resistance balancing resistor value, Ohms. Set once during board production.
166 +* Address unique device address. Each BMS Logic device connected to a BMS Main controller must have a unique address.
166 166  
167 -Секция **Measurements **содержит в себе информацию о всех ячейках, подключенных к устройству. Ключевые параметры отображены по вертикали относительно соответствующей ячейки Cell 1 - Cell 18.
168 +The **Measurements** area contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 18).
168 168  
169 -* Поле "//Volts" //отображает напряжение ячейки в вольтах. Минимальное и максимальное напряжение среди всех ячеек выделяется синим и красным фоном соответственно. Над цифровым полем располагается графическое представление напряжения ячейки. Ниже располагаются поля для указания действительного напряжения ячейки. Разница между заданным и измеренным напряжениями ячейки показывается в строке Difference и выделяется цветом в зависимости от степени различия. Таким образом можно легко отследить погрешность измерения напряжения у устройства BMS Logic. Пороговые значения погрешностей задаются в разделе Commands в нижней части окна. Также с помощью кнопки "Capture" можно запомнить текущее значение напряжений всех ячеек в случае, если требуется сравнить несколько устройств BMS Logic между собой.
170 -* Аналогичным образом отображаются показания температурных датчиков для каждой ячейки в поле "//°C//" – имеется возможность запомнить показания температур и отслеживать разницу измереных и заданных показаний в реальном времени. Модель используемого температурного датчика задается в поле "Temperature sensor" ниже.
171 -* Строка "//Inputs (C0-C18)//" отображает статус подключения соответствующей измерительной линии напряжения.
172 -* Строка "//Discharge//" содержит флаги включения балансировки соответствующей ячейки.
173 -* Строка "//uOhm//" не используется.
174 -* Поле "//Board temperature//" показывает температуру платы BMS Logic. В полях справа задается температура, измеренная внешним термометром (первое поле), а также максимально допустимая погрешность измерения (второе поле). Текущая погрешность измерения показывается в третьем поле с цветовым выделением.
175 -* Поле "//Temperature sensor//" позволяет установить модель используемого для измерения температуры термистора.
176 -* Поле "//Voltage difference//" указывает на разницу между минимальной и максимальной напряжениями ячеек.
177 -* Поле "//Temperature difference//" указывает на разницу между минимальной и максимальной температурами.
170 +* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other.
171 +* The temperature sensor readings for each cell in the "//°C//" field are displayed similarly there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the "Temperature sensor" field below.
172 +* The **"**//Inputs (C0-C18)//**"** row displays the connection status of the corresponding voltage measurement line.
173 +* The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell.
174 +* The **"**//uOhm//**"** row is not used.
175 +* The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting.
176 +* The **"**//Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement.
177 +* The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages.
178 +* The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures.
178 178  
179 -Секция **Commands **содержит поля для передачи команд устройству, а также пороговые значения погрешностей для измерения напряжения и температуры:
180 +The **Commands** area contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:
180 180  
181 -* Discharge all cells команда на балансировку всех ячеек;
182 -* Sleep перевод устройства в режим сна;
183 -* Wake up перевод устройства из режима сна в рабочий режим;
184 -* Bootloader перевод устроства в режим загрузчика;
185 -* Yellow voltage difference пороговое значение погрешности измерения напряжения ячейки для желтого уровня, В;
186 -* Red voltage difference пороговое значение погрешности измерения напряжения ячейки для красного уровня, В;
187 -* Yellow temperature difference пороговое значение погрешности измерения температуры ячейки для желтого уровня, В;
188 -* Yellow temperature difference пороговое значение погрешности измерения температуры ячейки для красного уровня, В;
189 -* Строка "Resistance calculation" не используется.
182 +* Discharge all cells command to balance all cells.
183 +* Sleep put the device into sleep mode.
184 +* Wake up take the device out of sleep mode into operational mode.
185 +* Bootloader put the device into bootloader mode.
186 +* Yellow voltage difference threshold value for cell voltage measurement error for the yellow level, V.
187 +* Red voltage difference threshold value for cell voltage measurement error for the red level, V.
188 +* Yellow temperature difference threshold value for cell temperature measurement error for the yellow level, °C.
189 +* Red temperature difference threshold value for cell temperature measurement error for the red level, °C.
190 +* The "Resistance calculation" row is not used.
190 190  
191 191  == BMS Display ==
192 192  
193 -Окно монитора BMS Display описано в [[документации на BMS Display>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]].
194 +The BMS Display monitor window is described in the [[BMS Display documentation>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]].
194 194  
195 195  == BMS Indication ==
196 196  
197 -Окно монитора BMS Indication описано в [[документации на BMS Indication>>doc:Battery management systems.BMS Indication.3\. Configuration.WebHome]].
198 +The BMS Indication monitor window is described in the [[BMS Indication documentation>>doc:Battery management systems.BMS Indication.3\. Configuration.WebHome]].
198 198  
199 199  == Updater ==
200 200  
201 -Модуль обновления через загрузчик позволяет обновлять встроенное ПО устройств BMS Mini, BMS Mini S, BMS Main X, BMS Main 2.1, BMS Logic 12/18/RET/12S, BMS Display, BMS IMD.
202 +The updater module allows updating the firmware of BMS Mini, BMS Mini S, BMS Main X, BMS Main 2.1, BMS Logic 12/18/RET/12S, BMS Display, and BMS IMD devices through the bootloader.
202 202  
203 -Процесс обновления через загрузчик описан в разделе "Обновление ВПО" в документации на соответствующее устройство (например, [[BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]).
204 +The process of updating through bootloader is described in the "Firmware Update" section of the documentation for the corresponding device (for example, [[BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]).
204 204  
205 205  == Unified bootloader ==
206 206  
207 -Модуль обновления через универсальный загрузчик позволяет обновлять встроенное ПО устройств BMS Main 3 и BMS Main 3X.
208 +The unified bootloader module allows updating the firmware of BMS Main 3 and BMS Main 3X.
208 208  
209 -Процесс обновления через универсальный загрузчик описан в разделе "Обновление ВПО" в документации на [[BMS Main 3>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]].
210 +The process of updating through unified bootloader is described in the "Firmware Update" section of the [[BMS Main 3 documentation>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]].
210 210  
211 211  == Log viewer ==
212 212  
213 -Модуль Log viewer позволяет анализировать лог-файлы устройства с возможностью построения графиков и табличного вывода выбранных параметров.
214 +The Log Viewer module allows you to analyze device log files with the capability to plot graphs and display selected parameters in a tabular format.
214 214  
215 -Для начала работы:
216 +To get started:
216 216  
217 -~1. Создайте новую базу данных с помощью кнопки «New base»
218 +1. Create a new database using the **"**New database**"** button.
218 218  
219 219  [[image:1766062577813-983.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="135" width="226"]]
220 220  
221 -2. Введите имя базы и выберите папку для хранения базы.
222 +2.
222 222  
224 +1. Enter a name for the database and select a folder to store it.
225 +
223 223  [[image:1766062577815-237.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="291" width="394"]]
224 224  
225 225  3. Импортируйте лог-файлы с помощью кнопки Import CSV