... ... @@ -45,6 +45,10 @@
45 45  
46 46  After successfully entering the password, the main "Unified Monitor" window opens, and the parameters begin to load.
47 47  
48 +(% class="box infomessage" %)
49 +(((
50 +If connection to the device is lost, the program will attempt to reconnect with previously entered credentials. Attempts will continue until the Stop button is pressed.
51 +)))
48 48  
49 49  The monitor windows is divided into three areas.
50 50  
... ... @@ -64,7 +64,7 @@
64 64  * Log in – open the re-authorization window.
65 65  * Change password – open the window to change the password for the current user.
66 66  * SD card – open the window for interacting with the installed SD card.
67 -* Update firmware – open the window for updating the device firmware via Unified Monitor. The update process via Unified Monitor is described in the documentation for the corresponding device (e.g., BMS Mini S). An SD card must be installed to perform an update in this mode.
71 +* Update firmware – open the window for updating the device firmware via Unified Monitor. The update process via Unified Monitor is described in the documentation for the corresponding device (e.g., [[BMS Mini S>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]]). An SD card must be installed to perform an update in this mode.
68 68  * Reboot – device restart.
69 69  * Go to bootloader – switch the device to bootloader mode.
70 70  
... ... @@ -91,146 +91,151 @@
91 91  * Unmount – Unmount the SD card.
92 92  * Format – Format the SD card to FAT32 format. The card must be unmounted before formatting.
93 93  
94 -{{comment}}
95 95  
96 -**В центральной области** отображаются параметры устройства (вкладка Settings), состояния устройства (State) и, если поддерживается, профильные данные устройства (Profile). 
97 97  
98 -Вкладки в данной области разделены на три колонки.
100 +**The central area** displays the device parameters (Settings tab), device states (State tab), and, if supported, device profile data (Profile tab).
99 99  
100 -* в первой колонке в древовидной форме отображаются группы параметров;
101 -* во второй отображаются записи для выбранной группы;
102 -* в третьей отображается детальное описание записи, поля для ввода нового значения и кнопка сохранения.
102 +The content in this area are divided into three columns:
103 103  
104 +* The first column displays parameter groups in a tree structure;
105 +* The second column displays entries for the selected group;
106 +* The third column displays a detailed description of the entry, fields for entering a new value, and a save button.
107 +
104 104  [[image:1766055020158-734.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="221" width="600"]]
105 105  
106 -Над колонкой групп параметров находятся следующие кнопки:
110 +Above the column of parameter groups there are the following buttons:
107 107  
108 -* Reload кнопки повторной загрузки всех параметров платы
109 -* Save кнопка одновременного сохранения всех измененных параметров
110 -* Export кнопка экпорта настроек из устройства в текстовый файл
111 -* Import кнопка импорта настроек из текстового файла в устройство. После импорта настроек следует нажать кнопку Save.
112 +* Reload reread all board parameters;
113 +* Save save all changed parameters simultaneously;
114 +* Export export settings from the device to a text file;
115 +* Import import settings from a text file into the device. After importing the settings, click the Save button.
112 112  
113 113  
114 114  
115 -**В нижней области** приводится история действий с устройством.
119 +**The bottom area** displays the history of actions performed with the device.
116 116  
117 117  [[image:1766054531745-297.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="73" width="600"]]
118 118  
119 119  == BMS Main 2.1 ==
120 120  
121 -Монитор BMS Main 2.1 позволяет подключиться к устройству через шину CAN. Для этого следует выбрать соответствующий CAN адаптер и выбрать устройство из списка (Systec, PEAK или Marathon) или задать номер COM-порта (BMS USB-CAN).
125 +The BMS Main 2.1 monitor allows you to connect the device via the CAN bus. To do this, select the corresponding CAN adapter and choose a device from the list (Systec, PEAK, or Marathon) or specify the COM port number (BMS USB-CAN).
122 122  
123 123  [[image:1766059864519-882.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="430"]]
124 124  
125 -Структура разделов и меню окна монитора аналогична Web интерфейсу и описана в [[документации на BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.WebHome]].
129 +The structure of the monitor window's sections and menus is similar to the Web interface and is described in the [[BMS Main 2.1 documentation>>doc:Battery management systems.BMS Main 2\.1 (End-of-Life).WebHome]].
126 126  
127 127  == BMS Logic 2.0 ==
128 128  
129 -[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]]Окно настройки и проверки BMS Logic 2.0 разделено на две области.
133 +[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]]
130 130  
131 -В **верхней части **содержится информация о всех ячейках, подключенных к устройству. Ключевые параметры отображены по вертикали относительно соответствующей ячейки Cell 1 - Cell 12.
135 +The BMS Logic 2.0 setup and verification window is divided into two areas.
132 132  
133 -* Поле "//Volts" //отображает напряжение ячейки в вольтах. Минимальное и максимальное напряжение среди всех ячеек выделяется синим и красным фоном соответственно. Над цифровым полем располагается графическое представление напряжения ячейки. Ниже располагаются поля для указания действительного напряжения ячейки. Разница между заданным и измеренным напряжениями ячейки показывается в строке Difference и выделяется цветом в зависимости от степени различия. Таким образом можно легко отследить погрешность измерения напряжения у устройства BMS Logic. Пороговые значения погрешностей задаются в разделе Commands в нижней части окна. Также с помощью кнопки "Capture" можно запомнить текущее значение напряжений всех ячеек в случае, если требуется сравнить несколько устройств BMS Logic между собой.
134 -* Аналогичным образом отображаются показания температурных датчиков в поле "//°C//" – имеется возможность запомнить показания температур и отслеживать разницу измереных и заданных показаний в реальном времени. Модель используемого температурного датчика задается в поле "Temperature sensor" ниже.
135 -* Строка "//Discharge//" содержит флаги включения балансировки соответствующей ячейки.
136 -* Поле "//Board temperature//" показывает температуру платы BMS Logic. В полях справа задается температура, измеренная внешним термометром (первое поле), а также максимально допустимая погрешность измерения (второе поле). Текущая погрешность измерения показывается в третьем поле с цветовым выделением.
137 -* Поле "//Temperature sensor//" позволяет установить модель используемого для измерения температуры термистора.
138 -* Поле "//Voltage difference//" указывает на разницу между минимальной и максимальной напряжениями ячеек.
139 -* Поле "//Temperature difference//" указывает на разницу между минимальной и максимальной температурами.
137 +**The upper area** contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 12).
140 140  
141 -Секция **Commands **содержит поля для передачи команд устройству, а также пороговые значения погрешностей для измерения напряжения и температуры:
139 +* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other.
140 +* The temperature sensor readings in the **"**//°C//**"** field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the **"**Temperature sensor**"** field below.
141 +* The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell.
142 +* The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting.
143 +* The **"**//Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement.
144 +* The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages.
145 +* The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures.
142 142  
143 -* Discharge all cells – команда на балансировку всех ячеек;
144 -* Yellow voltage difference – пороговое значение погрешности измерения напряжения ячейки для желтого уровня, В;
145 -* Red voltage difference – пороговое значение погрешности измерения напряжения ячейки для красного уровня, В;
146 -* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для желтого уровня, В;
147 -* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для красного уровня, В.
147 +The **Commands **area contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:
148 148  
149 +* Discharge all cells – command to balance all cells.
150 +* Yellow voltage difference – threshold value for cell voltage measurement error for the yellow level, V.
151 +* Red voltage difference – threshold value for cell voltage measurement error for the red level, V.
152 +* Yellow temperature difference – threshold value for cell temperature measurement error for the yellow level, °C.
153 +* Red temperature difference – threshold value for cell temperature measurement error for the red level, °C.
154 +
149 149  == BMS Logic 12/18/RET ==
150 150  
151 -Процесс подключения и настройки устройств BMS Logic 12/18/RET/12S описан в документации на соответствующее устройство (например, [[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).
157 +The process of connecting and configuring the BMS Logic 12/18/RET/12S devices is described in the documentation for the corresponding device (for example, [[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).
152 152  
153 -[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]]Окно настройки и проверки устрйоств BMS Logic разделено на три области.
159 +[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]]
154 154  
161 +The BMS Logic device setup and verification window is divided into three areas.
155 155  
156 -Секция **Info **содержит в себе информацию об устройстве:
163 +The **Info** area contains device information:
157 157  
158 -* Hardware version – версия аппаратного обеспечения;
159 -* Software version – версия программного обеспечения;
160 -* Cell count количетво подключенных на данный момент ячеек;
161 -* Serial number серийный номер устройства. Сериный номер сохраняется единоразово во время производства платы;
162 -* Balancing resistance номинал балансировочных резисторов, Ом. Задается единоразово во время производства платы;
163 -* Address уникальный адрес устройства. Каждое устройство BMS Logic, подключенное контроллеру BMS Main, должно иметь уникальный адрес.
165 +* Hardware version;
166 +* Software version;
167 +* Cell count number of cells currently connected.
168 +* Serial number device serial number. The serial number is saved once during board production.
169 +* Balancing resistance balancing resistor value, Ohms. Set once during board production.
170 +* Address unique device address. Each BMS Logic device connected to a BMS Main controller must have a unique address.
164 164  
165 -Секция **Measurements **содержит в себе информацию о всех ячейках, подключенных к устройству. Ключевые параметры отображены по вертикали относительно соответствующей ячейки Cell 1 - Cell 18.
172 +The **Measurements** area contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 18).
166 166  
167 -* Поле "//Volts" //отображает напряжение ячейки в вольтах. Минимальное и максимальное напряжение среди всех ячеек выделяется синим и красным фоном соответственно. Над цифровым полем располагается графическое представление напряжения ячейки. Ниже располагаются поля для указания действительного напряжения ячейки. Разница между заданным и измеренным напряжениями ячейки показывается в строке Difference и выделяется цветом в зависимости от степени различия. Таким образом можно легко отследить погрешность измерения напряжения у устройства BMS Logic. Пороговые значения погрешностей задаются в разделе Commands в нижней части окна. Также с помощью кнопки "Capture" можно запомнить текущее значение напряжений всех ячеек в случае, если требуется сравнить несколько устройств BMS Logic между собой.
168 -* Аналогичным образом отображаются показания температурных датчиков для каждой ячейки в поле "//°C//" – имеется возможность запомнить показания температур и отслеживать разницу измереных и заданных показаний в реальном времени. Модель используемого температурного датчика задается в поле "Temperature sensor" ниже.
169 -* Строка "//Inputs (C0-C18)//" отображает статус подключения соответствующей измерительной линии напряжения.
170 -* Строка "//Discharge//" содержит флаги включения балансировки соответствующей ячейки.
171 -* Строка "//uOhm//" не используется.
172 -* Поле "//Board temperature//" показывает температуру платы BMS Logic. В полях справа задается температура, измеренная внешним термометром (первое поле), а также максимально допустимая погрешность измерения (второе поле). Текущая погрешность измерения показывается в третьем поле с цветовым выделением.
173 -* Поле "//Temperature sensor//" позволяет установить модель используемого для измерения температуры термистора.
174 -* Поле "//Voltage difference//" указывает на разницу между минимальной и максимальной напряжениями ячеек.
175 -* Поле "//Temperature difference//" указывает на разницу между минимальной и максимальной температурами.
174 +* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other.
175 +* The temperature sensor readings for each cell in the "//°C//" field are displayed similarly there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the "Temperature sensor" field below.
176 +* The **"**//Inputs (C0-C18)//**"** row displays the connection status of the corresponding voltage measurement line.
177 +* The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell.
178 +* The **"**//uOhm//**"** row is not used.
179 +* The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting.
180 +* The **"**//Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement.
181 +* The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages.
182 +* The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures.
176 176  
177 -Секция **Commands **содержит поля для передачи команд устройству, а также пороговые значения погрешностей для измерения напряжения и температуры:
184 +The **Commands** area contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:
178 178  
179 -* Discharge all cells команда на балансировку всех ячеек;
180 -* Sleep перевод устройства в режим сна;
181 -* Wake up перевод устройства из режима сна в рабочий режим;
182 -* Bootloader перевод устроства в режим загрузчика;
183 -* Yellow voltage difference пороговое значение погрешности измерения напряжения ячейки для желтого уровня, В;
184 -* Red voltage difference пороговое значение погрешности измерения напряжения ячейки для красного уровня, В;
185 -* Yellow temperature difference пороговое значение погрешности измерения температуры ячейки для желтого уровня, В;
186 -* Yellow temperature difference пороговое значение погрешности измерения температуры ячейки для красного уровня, В;
187 -* Строка "Resistance calculation" не используется.
186 +* Discharge all cells command to balance all cells.
187 +* Sleep put the device into sleep mode.
188 +* Wake up take the device out of sleep mode into operational mode.
189 +* Bootloader put the device into bootloader mode.
190 +* Yellow voltage difference threshold value for cell voltage measurement error for the yellow level, V.
191 +* Red voltage difference threshold value for cell voltage measurement error for the red level, V.
192 +* Yellow temperature difference threshold value for cell temperature measurement error for the yellow level, °C.
193 +* Red temperature difference threshold value for cell temperature measurement error for the red level, °C.
194 +* The "Resistance calculation" row is not used.
188 188  
189 189  == BMS Display ==
190 190  
191 -Окно монитора BMS Display описано в [[документации на BMS Display>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]].
198 +The BMS Display monitor window is described in the [[BMS Display documentation>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]].
192 192  
193 193  == BMS Indication ==
194 194  
195 -Окно монитора BMS Indication описано в [[документации на BMS Indication>>doc:Battery management systems.BMS Indication.3\. Configuration.WebHome]].
202 +The BMS Indication monitor window is described in the [[BMS Indication documentation>>doc:Battery management systems.BMS Indication.3\. Configuration.WebHome]].
196 196  
197 197  == Updater ==
198 198  
199 -Модуль обновления через загрузчик позволяет обновлять встроенное ПО устройств BMS Mini, BMS Mini S, BMS Main X, BMS Main 2.1, BMS Logic 12/18/RET/12S, BMS Display, BMS IMD.
206 +The updater module allows updating the firmware of BMS Mini, BMS Mini S, BMS Main X, BMS Main 2.1, BMS Logic 12/18/RET/12S, BMS Display, and BMS IMD devices through the bootloader.
200 200  
201 -Процесс обновления через загрузчик описан в разделе "Обновление ВПО" в документации на соответствующее устройство (например, [[BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]).
208 +The process of updating through bootloader is described in the "Firmware Update" section of the documentation for the corresponding device (for example, [[BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]).
202 202  
203 203  == Unified bootloader ==
204 204  
205 -Модуль обновления через универсальный загрузчик позволяет обновлять встроенное ПО устройств BMS Main 3 и BMS Main 3X.
212 +The unified bootloader module allows updating the firmware of BMS Main 3 and BMS Main 3X.
206 206  
207 -Процесс обновления через универсальный загрузчик описан в разделе "Обновление ВПО" в документации на [[BMS Main 3>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]].
214 +The process of updating through unified bootloader is described in the "Firmware Update" section of the [[BMS Main 3 documentation>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]].
208 208  
209 209  == Log viewer ==
210 210  
211 -Модуль Log viewer позволяет анализировать лог-файлы устройства с возможностью построения графиков и табличного вывода выбранных параметров.
218 +The Log Viewer module allows you to analyze device log files with the capability to plot graphs and display selected parameters in a tabular format.
212 212  
213 -Для начала работы:
220 +To get started:
214 214  
215 -~1. Создайте новую базу данных с помощью кнопки «New base»
222 +~1. Create a new database using the **"**New database**"** button.
216 216  
217 217  [[image:1766062577813-983.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="135" width="226"]]
218 218  
219 -2. Введите имя базы и выберите папку для хранения базы.
226 +2. Enter a name for the database and select a folder to store it.
220 220  
221 221  [[image:1766062577815-237.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="291" width="394"]]
222 222  
223 -3. Импортируйте лог-файлы с помощью кнопки Import CSV
230 +3. Import log files using the "Import CSV" button
224 224  
225 225  [[image:1766062577817-283.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="188" width="228"]]
226 226  
227 -4. Выберите необходимые лог-файлы для импорта
234 +4. Select the log files you wish to import
228 228  
229 229  [[image:1766062577818-783.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="373"]]
230 230  
231 -Для отображения данных в графическом виде выберете вкладку "Graphic view". На графиках отображаются только выбранные в левой части окна параметры. В полях From и To задается временной диапазон, за который требуется построить график. Поддерживаются режимы одного и двух окон с графиками, а также автоматическое или ручное масштабирование графиков по вертикали. В нижнем правом углу выбирается отображаемый на графиках временной промежуток.
238 +To display data in graphical form, select the "Graphic view" tab. The graphs show only the parameters selected in the left part of the window. The "From" and "To" fields define the time range for which to plot the graph. The module supports both single and dual graph window modes, as well as automatic or manual vertical scaling of the graphs. The time interval displayed on the graphs can be selected in the lower right corner.
232 232  
233 -[[image:1766062707743-878.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="325" width="432"]]Для отображения данных в графическом виде выберете вкладку Table view. В полях From и To можно выбрать временной диапазон, за который требуется вывести данные. В столбцах отображаются только выбранные в левой части окна параметры.
240 +[[image:1766062707743-878.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="325" width="432"]]
234 234  
242 +To display data in tabular form, select the "Table view" tab. The "From" and "To" fields allow you to select the time range for which to display data. Only the parameters selected in the left part of the window are shown in the columns.
243 +
235 235  [[image:1766062736332-834.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="315" width="419"]]
236 -~{~{/comment}}