Changes for page Обзор программы
Last modified by Admin on 2026/04/27 12:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,231 +1,245 @@ 1 -TBA 2 -{{comment}} 1 +ElectricDeviceMonitor is a software to configure, debug and updating Movicom Electric devices. 3 3 4 -Программа ElectricDeviceMonitor – это средство для настройки, отладки и обновления продукции Мовиком Электрик. 5 - 6 6 [[image:1766053068470-669.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="336" width="343"]] 7 7 8 - Программасостоитизследующихкомпонентов:5 +Application consists of following modules: 9 9 10 -* Unified monitor – универсальныймодульдлясвязисустройствамиBMS Main 3/3X, BMS Main X, BMS Mini, BMS Mini SчерезшинуCAN, USBилиTCPсоединение,атакжеBMS IMDпошинеCAN.11 -* Мониторыустройств:12 -** BMS Main 2.1 – модульдлясвязисконтроллером батареиBMS Main 2.1пошинеCAN;13 -** BMS Logic 2.0 – модульдлясвязисBMS Logic 2.0пошинеRS-485;14 -** BMS Logic 12/18/RET – модульдлясвязисустройствамиBMS Logic 12, BMS Logic 18, BMS Logic RET, BMS Logic 12SпошинеRS-485;15 -** BMS Display 1.x – модульдлясвязисустройствамиBMS DisplayпошинеCAN;16 -** BMS Indication 1.x – модульдлясвязисустройствамиBMS IndicationпошинеCAN;17 -** BMS Main 1.4 – модульдлясвязисустаревшимиконтроллерами батареиBMS Main 1.2.-1.4*пошинеCAN;18 -** BMS Crown 1.x – модульдлясвязисустройствамиBMS Crown*пошинеCAN;19 -** BMS Power Control 1.x – модульдлясвязисустройствамиBMS Power Control*пошинеCAN;20 -* Обновлениеустройств:21 -** Updater – универсальныймодульобновленияустройствпошинеCAN, RS-485, USBиTCPсоединению22 -** Unified bootloader – модульобновленияустройствBMS Main 3/3XпоUSB.23 -* Log viewer – модульпросмотралог-файловустройства.7 +* Unified monitor – unified module to communicate with BMS Main 3/3X, BMS Main X, BMS Mini, BMS Mini S devices via CAN, USB or TCP connection, and BMS IMD device via CAN bus. 8 +* Device monitors: 9 +** BMS Main 2.1 – module to communicate with BMS Main 2.1 battery controller by CAN bus; 10 +** BMS Logic 2.0 – module to communicate with BMS Logic 2.0 measuring module by RS-485 bus; 11 +** BMS Logic 12/18/RET – module to communicate with BMS Logic 12, BMS Logic 18, BMS Logic RET, BMS Logic 12S devices by RS-485 bus; 12 +** BMS Display 1.x – module to communicate with BMS Display by CAN bus; 13 +** BMS Indication 1.x – module to communicate with BMS Indication by CAN bus; 14 +** BMS Main 1.4 – module to communicate with legacy BMS Main 1.2.-1.4* battery controllers by CAN bus; 15 +** BMS Crown 1.x – module to communicate with BMS Crown* devices by CAN bus; 16 +** BMS Power Control 1.x – module to communicate with BMS Power Control* devices by CAN bus; 17 +* Device update: 18 +** Updater – universal device update module working by CAN, RS-485, USB or TCP connections; 19 +** Unified bootloader – a module to update BMS Main 3/3X devices by USB. 20 +* Log viewer – a module to view device log files. 24 24 25 -~* Устройствоявляетсяустаревшимибольшенепроизводится.22 +~* Device is obsolete and no longer produced. 26 26 24 + 27 27 == Unified monitor == 28 28 29 -Unified monitorподдерживаетразличныеспособыподключенияк устройствам:27 +Unified supports the different methods to connect to a device: 30 30 31 -* ПриподключениичерезUSBследуетуказатьномерпоследовательногопортаустройства;32 -* ПриподключениипошинеCAN33 -** черезадаптерBMS USB-CANследуетуказатьномерCOMпорта,скоростьсоединенияиадресустройства;34 -** дляостальныхадаптеровследуетвыбратьустройствоизспискаитакжеуказатьскоростьсоединенияиадресустройства;35 -* ПриподключениипоTCPследуетвводитьIPадресцелевогоустройствавлокальнойсети.29 +* When connecting via USB it is necessary to set the COM port; 30 +* When connecting via CAN 31 +** with BMS USB-CAN adapter it is necessary to set the COM port, bus speed and device address; 32 +** for other adapters it is necessary to select a device from the list, specify the bus speed and device address; 33 +* When connecting via TCP, enter the IP address of the target device in the local network. 36 36 37 37 [[image:1766054835921-455.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="229" width="415"]] 38 38 39 - Послеуспешногоподключениявверхнейчасти окна кнопка"Start"станетнеактивнойипоявитсяокноавторизациипользователя.Этосвидетельствуетобуспешномподключении.37 +After a successful connection, the "Start" button at the top left corner will become inactive, and a user authorization window will appear. This indicates a successful connection. 40 40 41 -* Guest - Гостевойдоступдляпросмотрасостояниябатареи.Нетразрешенийнаизмененийкаких-либонастроек;42 -* User - Стандартныйпользовательскийдоступсразрешениемнаизменениебольшинстванастроек;43 -* Service - Сервисныйдоступдляприозводителейбатарей.Имеетдоступдонекоторыхдополнительныхнастроек;44 -* Manufacturer - ЭтотаккаунтиспользуетсяпроизводителемBMSинепредназначендляпубличногодоступа.39 +* Guest - Guest access to view battery state. No permissions to change and view any settings; 40 +* User - A common user access with permissions to change almost all the settings; 41 +* Service - A service account for battery manufacturers. Has access to some additional settings; 42 +* Manufacturer - This account is used by BMS manufacturer and not accessible for others. 45 45 46 46 [[image:1766054201828-790.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 47 47 48 - ПослеуспешноговводапароляоткрываетсяглавноеокноUnifiedmonitorипроисходитзагрузкапараметров.46 +After successfully entering the password, the main "Unified Monitor" window opens, and the parameters begin to load. 49 49 48 +(% class="box infomessage" %) 49 +((( 50 +If connection to the device is lost, the program will attempt to reconnect with previously entered credentials. Attempts will continue until the Stop button is pressed. 51 +))) 50 50 51 - Окномонитораразделенонатриобласти.53 +The monitor windows is divided into three areas. 52 52 53 -[[image:1766054651152-306.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="52" width="600"]] **В верхней области** отображаются:55 +[[image:1766054651152-306.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="52" width="600"]] 54 54 55 -* элементы управления, предназначенные для запуска и останова информационного обмена с устройством; 56 -* информация об устройстве (название и серийный номер, версия аппаратного и программного обеспечения, версия загрузчика); 57 -* время на часах устройства с возможностью синхронизации; 58 -* элементы управления для выполнения действий с устройством (изменение пароля, перезапуск, сброс настроек и др.). 57 +The **top area** displays: 59 59 60 -[[image:1766055717373-251.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="200" width="166"]]Меню "Device" содержит в себе следующие пункты меню: 59 +* Controls for starting and stopping data exchange with the device. 60 +* Device information (name and serial number, hardware and software version, bootloader version). 61 +* The device's clock time with synchronization capability. 62 +* Controls for performing actions on the device (changing the password, restarting, resetting settings, etc.). 61 61 62 -* Log in – вызов окна повторной авторизации; 63 -* Change password – вызов окна смены пароля для текущего пользователя; 64 -* SD card – вызов окна взаимодействия с установленной SD картой; 65 -* Update firmware – вызов окна обновления ВПО устройства через Unified monitor. Процесс обновления через Unified monitor описан в документации на соответствующее устройство (например, [[BMS Mini S>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]]). Для обновления в этом режиме обязательно должна быть установлена SD карта; 66 -* Reboot – перезапуск устройства; 67 -* Go to bootloader – перевод устройства в режим загрузчика. 64 +[[image:1766055717373-251.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="200" width="166"]] 68 68 69 - [[image:1766059260100-912.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]Меню"Settings"содержит пункт для сброса настроек устройства.66 +The "Device" menu contains the following items: 70 70 68 +* Log in – open the re-authorization window. 69 +* Change password – open the window to change the password for the current user. 70 +* SD card – open the window for interacting with the installed SD card. 71 +* Update firmware – open the window for updating the device firmware via Unified Monitor. The update process via Unified Monitor is described in the documentation for the corresponding device (e.g., [[BMS Mini S>>doc:Battery management systems.BMS Mini S.6\. Firmware update.WebHome]]). An SD card must be installed to perform an update in this mode. 72 +* Reboot – device restart. 73 +* Go to bootloader – switch the device to bootloader mode. 71 71 72 -[[image:176605 6213709-221.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="276"width="600"]]ОкновзаимодействиясSDкартой****состоитиз двух частей:75 +[[image:1766059260100-912.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]"Settings" menu contains the item to reset the device settings. 73 73 74 -* в левой части располагается содержимое SD карты. 75 -* в правой части располагается содержимое выбранной папки 76 76 77 - Дляскачиванияфайлас SD карты (папки скачивать нельзя) следует выбрать файл в левой части окна и нажать на стрелку посередине.78 +[[image:1766056213709-221.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="276" width="600"]] 78 78 79 - ВправомверхнемуглунаходитсяменюдействийсSD картой.80 +The SD card interaction window consists of two parts: 80 80 81 -[[image:1766058987135-535.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]В этом меню: 82 +* left part displays the contents of the SD card; 83 +* right part displays the contents of the selected folder. 82 82 83 -* Reload status – обновить состояние SD карты; 84 -* Mount – примонтировать SD карту; 85 -* Unmount – размонтировать SD карту; 86 -* Format – отформатировать SD карту в формат FAT32. Перед форматированием обязательно следует размонтировать карту. 85 +To download a file from the SD card (folders cannot be downloaded), select the file in the left part of the window and click the arrow in the middle. 87 87 87 +In the upper right corner, there is a menu for actions with the SD card. 88 88 89 +[[image:1766058987135-535.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 89 89 90 - **Вцентральной области** отображаются параметры устройства (вкладка Settings),состояния устройства (State) и, если поддерживается, профильные данные устройства (Profile).91 +In this menu: 91 91 92 -Вкладки в данной области разделены на три колонки. 93 +* Reload status – Refresh the SD card status. 94 +* Mount – Mount the SD card. 95 +* Unmount – Unmount the SD card. 96 +* Format – Format the SD card to FAT32 format. The card must be unmounted before formatting. 93 93 94 -* в первой колонке в древовидной форме отображаются группы параметров; 95 -* во второй отображаются записи для выбранной группы; 96 -* в третьей отображается детальное описание записи, поля для ввода нового значения и кнопка сохранения. 97 97 99 + 100 +**The central area** displays the device parameters (Settings tab), device states (State tab), and, if supported, device profile data (Profile tab). 101 + 102 +The content in this area are divided into three columns: 103 + 104 +* The first column displays parameter groups in a tree structure; 105 +* The second column displays entries for the selected group; 106 +* The third column displays a detailed description of the entry, fields for entering a new value, and a save button. 107 + 98 98 [[image:1766055020158-734.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="221" width="600"]] 99 99 100 - Надколонкойгрупппараметровнаходятсяследующиекнопки:110 +Above the column of parameter groups there are the following buttons: 101 101 102 -* Reload –кнопкиповторнойзагрузкивсех параметров платы103 -* Save –кнопкаодновременногосохранениявсехизмененных параметров104 -* Export –кнопкаэкпортанастроекизустройствавтекстовыйфайл105 -* Import –кнопкаимпортанастроекизтекстовогофайлавустройство.ПослеимпортанастроекследуетнажатькнопкуSave.112 +* Reload – reread all board parameters; 113 +* Save – save all changed parameters simultaneously; 114 +* Export – export settings from the device to a text file; 115 +* Import – import settings from a text file into the device. After importing the settings, click the Save button. 106 106 107 107 108 108 109 -** Внижнейобласти**приводитсяисториядействийсустройством.119 +**The bottom area** displays the history of actions performed with the device. 110 110 111 111 [[image:1766054531745-297.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="73" width="600"]] 112 112 113 113 == BMS Main 2.1 == 114 114 115 - МониторBMS Main 2.1позволяетподключитьсякустройствучерезшинуCAN.ДляэтогоследуетвыбратьсоответствующийCANадаптеривыбратьустройствоизсписка(Systec, PEAKилиMarathon)илизадатьномерCOM-порта(BMS USB-CAN).125 +The BMS Main 2.1 monitor allows you to connect the device via the CAN bus. To do this, select the corresponding CAN adapter and choose a device from the list (Systec, PEAK, or Marathon) or specify the COM port number (BMS USB-CAN). 116 116 117 117 [[image:1766059864519-882.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="430"]] 118 118 119 - СтруктураразделовименюокнамониторааналогичнаWebинтерфейсуиописанав[[документациинаBMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.WebHome]].129 +The structure of the monitor window's sections and menus is similar to the Web interface and is described in the [[BMS Main 2.1 documentation>>doc:Battery management systems.BMS Main 2\.1.WebHome]]. 120 120 121 121 == BMS Logic 2.0 == 122 122 123 -[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]] Окно настройки и проверки BMS Logic 2.0 разделено на две области.133 +[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]] 124 124 125 - В**верхнейчасти**содержится информация о всех ячейках, подключенных к устройству.Ключевыепараметрыотображеныповертикалиотносительно соответствующей ячейки Cell1-Cell 12.135 +The BMS Logic 2.0 setup and verification window is divided into two areas. 126 126 127 -* Поле "//Volts" //отображает напряжение ячейки в вольтах. Минимальное и максимальное напряжение среди всех ячеек выделяется синим и красным фоном соответственно. Над цифровым полем располагается графическое представление напряжения ячейки. Ниже располагаются поля для указания действительного напряжения ячейки. Разница между заданным и измеренным напряжениями ячейки показывается в строке Difference и выделяется цветом в зависимости от степени различия. Таким образом можно легко отследить погрешность измерения напряжения у устройства BMS Logic. Пороговые значения погрешностей задаются в разделе Commands в нижней части окна. Также с помощью кнопки "Capture" можно запомнить текущее значение напряжений всех ячеек в случае, если требуется сравнить несколько устройств BMS Logic между собой. 128 -* Аналогичным образом отображаются показания температурных датчиков в поле "//°C//" – имеется возможность запомнить показания температур и отслеживать разницу измереных и заданных показаний в реальном времени. Модель используемого температурного датчика задается в поле "Temperature sensor" ниже. 129 -* Строка "//Discharge//" содержит флаги включения балансировки соответствующей ячейки. 130 -* Поле "//Board temperature//" показывает температуру платы BMS Logic. В полях справа задается температура, измеренная внешним термометром (первое поле), а также максимально допустимая погрешность измерения (второе поле). Текущая погрешность измерения показывается в третьем поле с цветовым выделением. 131 -* Поле "//Temperature sensor//" позволяет установить модель используемого для измерения температуры термистора. 132 -* Поле "//Voltage difference//" указывает на разницу между минимальной и максимальной напряжениями ячеек. 133 -* Поле "//Temperature difference//" указывает на разницу между минимальной и максимальной температурами. 137 +**The upper area** contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 12). 134 134 135 -Секция **Commands **содержит поля для передачи команд устройству, а также пороговые значения погрешностей для измерения напряжения и температуры: 139 +* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other. 140 +* The temperature sensor readings in the **"**//°C//**"** field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the **"**Temperature sensor**"** field below. 141 +* The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell. 142 +* The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting. 143 +* The **"**//Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement. 144 +* The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages. 145 +* The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures. 136 136 137 -* Discharge all cells – команда на балансировку всех ячеек; 138 -* Yellow voltage difference – пороговое значение погрешности измерения напряжения ячейки для желтого уровня, В; 139 -* Red voltage difference – пороговое значение погрешности измерения напряжения ячейки для красного уровня, В; 140 -* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для желтого уровня, В; 141 -* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для красного уровня, В. 147 +The **Commands **area contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement: 142 142 149 +* Discharge all cells – command to balance all cells. 150 +* Yellow voltage difference – threshold value for cell voltage measurement error for the yellow level, V. 151 +* Red voltage difference – threshold value for cell voltage measurement error for the red level, V. 152 +* Yellow temperature difference – threshold value for cell temperature measurement error for the yellow level, °C. 153 +* Red temperature difference – threshold value for cell temperature measurement error for the red level, °C. 154 + 143 143 == BMS Logic 12/18/RET == 144 144 145 - ПроцессподключенияинастройкиустройствBMS Logic 12/18/RET/12Sописанвдокументациинасоответствующееустройство(например,[[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).157 +The process of connecting and configuring the BMS Logic 12/18/RET/12S devices is described in the documentation for the corresponding device (for example, [[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]). 146 146 147 -[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]] Окно настройки и проверки устрйоств BMS Logic разделено на три области.159 +[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]] 148 148 161 +The BMS Logic device setup and verification window is divided into three areas. 149 149 150 - Секция**Info**содержитвсебеинформацию об устройстве:163 +The **Info** area contains device information: 151 151 152 -* Hardware version – версия аппаратного обеспечения;153 -* Software version – версия программного обеспечения;154 -* Cell count –количетвоподключенныхнаданныймомент ячеек;155 -* Serial number –серийныйномерустройства.Сериныйномерсохраняетсяединоразовововремяпроизводстваплаты;156 -* Balancing resistance –номиналбалансировочныхрезисторов,Ом.Задаетсяединоразовововремяпроизводства платы;157 -* Address –уникальныйадресустройства.КаждоеустройствоBMS Logic,подключенноеконтроллеруBMS Main,должноиметьуникальныйадрес.165 +* Hardware version; 166 +* Software version; 167 +* Cell count – number of cells currently connected. 168 +* Serial number – device serial number. The serial number is saved once during board production. 169 +* Balancing resistance – balancing resistor value, Ohms. Set once during board production. 170 +* Address – unique device address. Each BMS Logic device connected to a BMS Main controller must have a unique address. 158 158 159 - Секция**Measurements**содержитвсебеинформациюовсехячейках,подключенныхкустройству.КлючевыепараметрыотображеныповертикалиотносительносоответствующейячейкиCell 1 - Cell 18.172 +The **Measurements** area contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 18). 160 160 161 -* Поле"//Volts"//отображаетнапряжениеячейкиввольтах.Минимальноеимаксимальноенапряжениесредивсехячееквыделяетсясинимикраснымфономсоответственно.Надцифровымполемрасполагаетсяграфическоепредставлениенапряженияячейки.Нижерасполагаютсяполядляуказаниядействительногонапряженияячейки.РазницамеждузаданнымиизмереннымнапряжениямиячейкипоказываетсявстрокеDifferenceивыделяетсяцветомвзависимостиотстепениразличия.ТакимобразомможнолегкоотследитьпогрешностьизмерениянапряженияуустройстваBMS Logic.ПороговыезначенияпогрешностейзадаютсявразделеCommandsвнижнейчастиокна. Такжеспомощьюкнопки"Capture"можнозапомнитьтекущеезначениенапряженийвсехячееквслучае,еслитребуетсясравнитьнесколькоустройствBMS Logicмеждусобой.162 -* Аналогичнымобразомотображаютсяпоказаниятемпературныхдатчиковдлякаждойячейки в поле"//°C//" –имеетсявозможностьзапомнитьпоказаниятемпературиотслеживатьразницуизмереныхизаданныхпоказанийвреальномвремени.Модельиспользуемоготемпературногодатчиказадаетсявполе"Temperature sensor"ниже.163 -* Строка"//Inputs (C0-C18)//"отображаетстатусподключениясоответствующейизмерительнойлиниинапряжения.164 -* Строка"//Discharge//"содержитфлагивключениябалансировкисоответствующейячейки.165 -* Строка"//uOhm//"неиспользуется.166 -* Поле"//Board temperature//"показываеттемпературуплатыBMS Logic.Вполяхсправазадаетсятемпература,измереннаявнешнимтермометром(первоеполе),атакжемаксимальнодопустимаяпогрешностьизмерения(второеполе).Текущаяпогрешностьизмеренияпоказываетсявтретьемполесцветовымвыделением.167 -* Поле"//Temperature sensor//"позволяетустановитьмодельиспользуемогодляизмерениятемпературытермистора.168 -* Поле"//Voltage difference//"указываетнаразницумеждуминимальнойимаксимальнойнапряжениямиячеек.169 -* Поле"//Temperature difference//"указываетнаразницумеждуминимальнойимаксимальнойтемпературами.174 +* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other. 175 +* The temperature sensor readings for each cell in the "//°C//" field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the "Temperature sensor" field below. 176 +* The **"**//Inputs (C0-C18)//**"** row displays the connection status of the corresponding voltage measurement line. 177 +* The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell. 178 +* The **"**//uOhm//**"** row is not used. 179 +* The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting. 180 +* The **"**//Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement. 181 +* The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages. 182 +* The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures. 170 170 171 - Секция**Commands**содержитполядляпередачикомандустройству,атакжепороговыезначенияпогрешностейдляизмерениянапряженияитемпературы:184 +The **Commands** area contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement: 172 172 173 -* Discharge all cells –команданабалансировкувсехячеек;174 -* Sleep –переводустройстваврежимсна;175 -* Wake up –переводустройстваизрежимаснаврабочийрежим;176 -* Bootloader –переводустростваврежимзагрузчика;177 -* Yellow voltage difference –пороговоезначениепогрешностиизмерениянапряженияячейкидляжелтогоуровня,В;178 -* Red voltage difference –пороговоезначениепогрешностиизмерениянапряженияячейкидлякрасногоуровня,В;179 -* Yellow temperature difference –пороговоезначениепогрешностиизмерениятемпературыячейкидляжелтогоуровня,В;180 -* Yellowtemperature difference–пороговоезначениепогрешностиизмерениятемпературыячейкидлякрасногоуровня,В;181 -* Строка"Resistance calculation"–неиспользуется.186 +* Discharge all cells – command to balance all cells. 187 +* Sleep – put the device into sleep mode. 188 +* Wake up – take the device out of sleep mode into operational mode. 189 +* Bootloader – put the device into bootloader mode. 190 +* Yellow voltage difference – threshold value for cell voltage measurement error for the yellow level, V. 191 +* Red voltage difference – threshold value for cell voltage measurement error for the red level, V. 192 +* Yellow temperature difference – threshold value for cell temperature measurement error for the yellow level, °C. 193 +* Red temperature difference – threshold value for cell temperature measurement error for the red level, °C. 194 +* The "Resistance calculation" row is not used. 182 182 183 183 == BMS Display == 184 184 185 - ОкномонитораBMS Displayописанов[[документациинаBMS Display>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]].198 +The BMS Display monitor window is described in the [[BMS Display documentation>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]]. 186 186 187 187 == BMS Indication == 188 188 189 - ОкномонитораBMS Indicationописанов[[документациинаBMS Indication>>doc:Battery management systems.BMS Indication.3\. Configuration.WebHome]].202 +The BMS Indication monitor window is described in the [[BMS Indication documentation>>doc:Battery management systems.BMS Indication.3\. Configuration.WebHome]]. 190 190 191 191 == Updater == 192 192 193 - МодульобновлениячереззагрузчикпозволяетобновлятьвстроенноеПОустройствBMS Mini, BMS Mini S, BMS Main X, BMS Main 2.1, BMS Logic 12/18/RET/12S, BMS Display, BMS IMD.206 +The updater module allows updating the firmware of BMS Mini, BMS Mini S, BMS Main X, BMS Main 2.1, BMS Logic 12/18/RET/12S, BMS Display, and BMS IMD devices through the bootloader. 194 194 195 - Процессобновлениячереззагрузчикописанвразделе"ОбновлениеВПО"вдокументациинасоответствующееустройство(например,[[BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]).208 +The process of updating through bootloader is described in the "Firmware Update" section of the documentation for the corresponding device (for example, [[BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]). 196 196 197 197 == Unified bootloader == 198 198 199 - МодульобновлениячерезуниверсальныйзагрузчикпозволяетобновлятьвстроенноеПОустройствBMS Main 3иBMS Main 3X.212 +The unified bootloader module allows updating the firmware of BMS Main 3 and BMS Main 3X. 200 200 201 - Процессобновлениячерезуниверсальныйзагрузчикописанвразделе"ОбновлениеВПО"вдокументациина[[BMS Main 3>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]].214 +The process of updating through unified bootloader is described in the "Firmware Update" section of the [[BMS Main 3 documentation>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]]. 202 202 203 203 == Log viewer == 204 204 205 - МодульLogviewerпозволяетанализироватьлог-файлыустройствасвозможностьюпостроенияграфиковитабличноговыводавыбранныхпараметров.218 +The Log Viewer module allows you to analyze device log files with the capability to plot graphs and display selected parameters in a tabular format. 206 206 207 - Дляначалаработы:220 +To get started: 208 208 209 -~1. Создайтеновуюбазуданныхспомощью кнопки «New base»222 +~1. Create a new database using the **"**New database**"** button. 210 210 211 211 [[image:1766062577813-983.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="135" width="226"]] 212 212 213 -2. Введитеимябазыивыберитепапкудляхранениябазы.226 +2. Enter a name for the database and select a folder to store it. 214 214 215 215 [[image:1766062577815-237.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="291" width="394"]] 216 216 217 -3. Импортируйтелог-файлыспомощьюкнопкиImport CSV230 +3. Import log files using the "Import CSV" button 218 218 219 219 [[image:1766062577817-283.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="188" width="228"]] 220 220 221 -4. Выберитенеобходимыелог-файлыдляимпорта234 +4. Select the log files you wish to import 222 222 223 223 [[image:1766062577818-783.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="373"]] 224 224 225 - Дляотображенияданныхвграфическомвидевыберетевкладку"Graphic view".Награфикахотображаютсятольковыбранныевлевойчастиокнапараметры.ВполяхFromиToзадаетсявременнойдиапазон,закоторыйтребуетсяпостроитьграфик.Поддерживаютсярежимыодногоидвухоконсграфиками,атакжеавтоматическоеилиручноемасштабированиеграфиковповертикали.Внижнемправомуглувыбираетсяотображаемыйнаграфикахвременнойпромежуток.238 +To display data in graphical form, select the "Graphic view" tab. The graphs show only the parameters selected in the left part of the window. The "From" and "To" fields define the time range for which to plot the graph. The module supports both single and dual graph window modes, as well as automatic or manual vertical scaling of the graphs. The time interval displayed on the graphs can be selected in the lower right corner. 226 226 227 -[[image:1766062707743-878.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="325" width="432"]] Для отображения данных в графическом виде выберете вкладку Table view. В полях From и To можно выбрать временной диапазон, за который требуется вывести данные. В столбцах отображаются только выбранные в левой части окна параметры.240 +[[image:1766062707743-878.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="325" width="432"]] 228 228 229 - [[image:1766062736332-834.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="315"width="419"]]242 +To display data in tabular form, select the "Table view" tab. The "From" and "To" fields allow you to select the time range for which to display data. Only the parameters selected in the left part of the window are shown in the columns. 230 230 231 -{{/comment}} 244 +[[image:1766062736332-834.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="315" width="419"]] 245 +{{comment}}{{/comment}}