Last modified by Admin on 2026/04/27 12:30

From version 11.2
edited by Admin
on 2026/04/02 13:53
Change comment: Renamed back-links.
To version 8.2
edited by Admin
on 2025/12/23 09:21
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -45,10 +45,6 @@
45 45  
46 46  After successfully entering the password, the main "Unified Monitor" window opens, and the parameters begin to load.
47 47  
48 -(% class="box infomessage" %)
49 -(((
50 -If connection to the device is lost, the program will attempt to reconnect with previously entered credentials. Attempts will continue until the Stop button is pressed.
51 -)))
52 52  
53 53  The monitor windows is divided into three areas.
54 54  
... ... @@ -68,7 +68,7 @@
68 68  * Log in – open the re-authorization window.
69 69  * Change password – open the window to change the password for the current user.
70 70  * SD card – open the window for interacting with the installed SD card.
71 -* Update firmware – open the window for updating the device firmware via Unified Monitor. The update process via Unified Monitor is described in the documentation for the corresponding device (e.g., [[BMS Mini S>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]]). An SD card must be installed to perform an update in this mode.
67 +* Update firmware – open the window for updating the device firmware via Unified Monitor. The update process via Unified Monitor is described in the documentation for the corresponding device (e.g., BMS Mini S). An SD card must be installed to perform an update in this mode.
72 72  * Reboot – device restart.
73 73  * Go to bootloader – switch the device to bootloader mode.
74 74  
... ... @@ -107,139 +107,134 @@
107 107  
108 108  [[image:1766055020158-734.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="221" width="600"]]
109 109  
110 -Above the column of parameter groups there are the following buttons:
106 +Above the column of parameter groups are the following buttons:
111 111  
112 -* Reload – reread all board parameters;
113 -* Save – save all changed parameters simultaneously;
114 -* Export – export settings from the device to a text file;
115 -* Import – import settings from a text file into the device. After importing the settings, click the Save button.
108 +* Reload – Reloads all board parameters.
109 +* Save – Saves all changed parameters simultaneously.
110 +* **Export** – Exports settings from the device to a text file.
111 +* **Import** – Imports settings from a text file into the device. After importing the settings, click the **Save** button.
116 116  
117 117  
118 118  
119 -**The bottom area** displays the history of actions performed with the device.
115 +**В нижней области** приводится история действий с устройством.
120 120  
121 121  [[image:1766054531745-297.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="73" width="600"]]
122 122  
123 123  == BMS Main 2.1 ==
124 124  
125 -The BMS Main 2.1 monitor allows you to connect the device via the CAN bus. To do this, select the corresponding CAN adapter and choose a device from the list (Systec, PEAK, or Marathon) or specify the COM port number (BMS USB-CAN).
121 +Монитор BMS Main 2.1 позволяет подключиться к устройству через шину CAN. Для этого следует выбрать соответствующий CAN адаптер и выбрать устройство из списка (Systec, PEAK или Marathon) или задать номер COM-порта (BMS USB-CAN).
126 126  
127 127  [[image:1766059864519-882.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="430"]]
128 128  
129 -The structure of the monitor window's sections and menus is similar to the Web interface and is described in the [[BMS Main 2.1 documentation>>doc:Battery management systems.BMS Main 2\.1.WebHome]].
125 +Структура разделов и меню окна монитора аналогична Web интерфейсу и описана в [[документации на BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.WebHome]].
130 130  
131 131  == BMS Logic 2.0 ==
132 132  
133 -[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]]
129 +[[image:1766163467280-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="600"]]Окно настройки и проверки BMS Logic 2.0 разделено на две области.
134 134  
135 -The BMS Logic 2.0 setup and verification window is divided into two areas.
131 +В **верхней части **содержится информация о всех ячейках, подключенных к устройству. Ключевые параметры отображены по вертикали относительно соответствующей ячейки Cell 1 - Cell 12.
136 136  
137 -**The upper area** contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 12).
133 +* Поле "//Volts" //отображает напряжение ячейки в вольтах. Минимальное и максимальное напряжение среди всех ячеек выделяется синим и красным фоном соответственно. Над цифровым полем располагается графическое представление напряжения ячейки. Ниже располагаются поля для указания действительного напряжения ячейки. Разница между заданным и измеренным напряжениями ячейки показывается в строке Difference и выделяется цветом в зависимости от степени различия. Таким образом можно легко отследить погрешность измерения напряжения у устройства BMS Logic. Пороговые значения погрешностей задаются в разделе Commands в нижней части окна. Также с помощью кнопки "Capture" можно запомнить текущее значение напряжений всех ячеек в случае, если требуется сравнить несколько устройств BMS Logic между собой.
134 +* Аналогичным образом отображаются показания температурных датчиков в поле "//°C//" – имеется возможность запомнить показания температур и отслеживать разницу измереных и заданных показаний в реальном времени. Модель используемого температурного датчика задается в поле "Temperature sensor" ниже.
135 +* Строка "//Discharge//" содержит флаги включения балансировки соответствующей ячейки.
136 +* Поле "//Board temperature//" показывает температуру платы BMS Logic. В полях справа задается температура, измеренная внешним термометром (первое поле), а также максимально допустимая погрешность измерения (второе поле). Текущая погрешность измерения показывается в третьем поле с цветовым выделением.
137 +* Поле "//Temperature sensor//" позволяет установить модель используемого для измерения температуры термистора.
138 +* Поле "//Voltage difference//" указывает на разницу между минимальной и максимальной напряжениями ячеек.
139 +* Поле "//Temperature difference//" указывает на разницу между минимальной и максимальной температурами.
138 138  
139 -* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other.
140 -* The temperature sensor readings in the **"**//°C//**"** field are displayed similarly – there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the **"**Temperature sensor**"** field below.
141 -* The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell.
142 -* The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting.
143 -* The **"**//Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement.
144 -* The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages.
145 -* The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures.
141 +Секция **Commands **содержит поля для передачи команд устройству, а также пороговые значения погрешностей для измерения напряжения и температуры:
146 146  
147 -The **Commands **area contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:
143 +* Discharge all cells – команда на балансировку всех ячеек;
144 +* Yellow voltage difference – пороговое значение погрешности измерения напряжения ячейки для желтого уровня, В;
145 +* Red voltage difference – пороговое значение погрешности измерения напряжения ячейки для красного уровня, В;
146 +* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для желтого уровня, В;
147 +* Yellow temperature difference – пороговое значение погрешности измерения температуры ячейки для красного уровня, В.
148 148  
149 -* Discharge all cells – command to balance all cells.
150 -* Yellow voltage difference – threshold value for cell voltage measurement error for the yellow level, V.
151 -* Red voltage difference – threshold value for cell voltage measurement error for the red level, V.
152 -* Yellow temperature difference – threshold value for cell temperature measurement error for the yellow level, °C.
153 -* Red temperature difference – threshold value for cell temperature measurement error for the red level, °C.
154 -
155 155  == BMS Logic 12/18/RET ==
156 156  
157 -The process of connecting and configuring the BMS Logic 12/18/RET/12S devices is described in the documentation for the corresponding device (for example, [[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).
151 +Процесс подключения и настройки устройств BMS Logic 12/18/RET/12S описан в документации на соответствующее устройство (например, [[BMS Logic 12>>doc:Battery management systems.BMS Logic 12.3\. Configuration.WebHome]]).
158 158  
159 -[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]]
153 +[[image:1766160450855-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="459" width="600"]]Окно настройки и проверки устрйоств BMS Logic разделено на три области.
160 160  
161 -The BMS Logic device setup and verification window is divided into three areas.
162 162  
163 -The **Info** area contains device information:
156 +Секция **Info **содержит в себе информацию об устройстве:
164 164  
165 -* Hardware version;
166 -* Software version;
167 -* Cell count number of cells currently connected.
168 -* Serial number device serial number. The serial number is saved once during board production.
169 -* Balancing resistance balancing resistor value, Ohms. Set once during board production.
170 -* Address unique device address. Each BMS Logic device connected to a BMS Main controller must have a unique address.
158 +* Hardware version – версия аппаратного обеспечения;
159 +* Software version – версия программного обеспечения;
160 +* Cell count количетво подключенных на данный момент ячеек;
161 +* Serial number серийный номер устройства. Сериный номер сохраняется единоразово во время производства платы;
162 +* Balancing resistance номинал балансировочных резисторов, Ом. Задается единоразово во время производства платы;
163 +* Address уникальный адрес устройства. Каждое устройство BMS Logic, подключенное контроллеру BMS Main, должно иметь уникальный адрес.
171 171  
172 -The **Measurements** area contains information about all cells connected to the device. Key parameters are displayed vertically relative to the corresponding cell (Cell 1 - Cell 18).
165 +Секция **Measurements **содержит в себе информацию о всех ячейках, подключенных к устройству. Ключевые параметры отображены по вертикали относительно соответствующей ячейки Cell 1 - Cell 18.
173 173  
174 -* The **"**//Volts//**"** field displays the cell voltage in volts. The minimum and maximum voltage among all cells are highlighted with blue and red backgrounds respectively. A graphical representation of the cell voltage is located above the numeric field. Below are fields for specifying the actual (reference) cell voltage. The difference between the reference and measured cell voltages is shown in the **"**Difference**"** row and is color-coded depending on the degree of discrepancy. This helps to easily track the voltage measurement error of the BMS Logic device. The error threshold values are set in the **"**Commands**"** section at the bottom of the window. Also, using the **"**Capture**"** button, it is possible to memorize the current voltage values of all cells if it is needed to compare several BMS Logic devices with each other.
175 -* The temperature sensor readings for each cell in the "//°C//" field are displayed similarly there is an option to memorize temperature readings and monitor the difference between measured and reference readings in real time. The model of the temperature sensor used is set in the "Temperature sensor" field below.
176 -* The **"**//Inputs (C0-C18)//**"** row displays the connection status of the corresponding voltage measurement line.
177 -* The **"**//Discharge//**"** row contains flags indicating whether balancing is enabled for the corresponding cell.
178 -* The **"**//uOhm//**"** row is not used.
179 -* The **"**//Board temperature//**"** field shows the temperature of the BMS Logic board. The fields to the right are for entering the temperature measured by an external thermometer (first field) and the maximum allowable measurement error (second field). The current measurement error is shown in the third field with color highlighting.
180 -* The **"**//Temperature sensor//**"** field allows you to set the model of the thermistor used for temperature measurement.
181 -* The **"**//Voltage difference//**"** field indicates the difference between the minimum and maximum cell voltages.
182 -* The **"**//Temperature difference//**"** field indicates the difference between the minimum and maximum temperatures.
167 +* Поле "//Volts" //отображает напряжение ячейки в вольтах. Минимальное и максимальное напряжение среди всех ячеек выделяется синим и красным фоном соответственно. Над цифровым полем располагается графическое представление напряжения ячейки. Ниже располагаются поля для указания действительного напряжения ячейки. Разница между заданным и измеренным напряжениями ячейки показывается в строке Difference и выделяется цветом в зависимости от степени различия. Таким образом можно легко отследить погрешность измерения напряжения у устройства BMS Logic. Пороговые значения погрешностей задаются в разделе Commands в нижней части окна. Также с помощью кнопки "Capture" можно запомнить текущее значение напряжений всех ячеек в случае, если требуется сравнить несколько устройств BMS Logic между собой.
168 +* Аналогичным образом отображаются показания температурных датчиков для каждой ячейки в поле "//°C//" – имеется возможность запомнить показания температур и отслеживать разницу измереных и заданных показаний в реальном времени. Модель используемого температурного датчика задается в поле "Temperature sensor" ниже.
169 +* Строка "//Inputs (C0-C18)//" отображает статус подключения соответствующей измерительной линии напряжения.
170 +* Строка "//Discharge//" содержит флаги включения балансировки соответствующей ячейки.
171 +* Строка "//uOhm//" не используется.
172 +* Поле "//Board temperature//" показывает температуру платы BMS Logic. В полях справа задается температура, измеренная внешним термометром (первое поле), а также максимально допустимая погрешность измерения (второе поле). Текущая погрешность измерения показывается в третьем поле с цветовым выделением.
173 +* Поле "//Temperature sensor//" позволяет установить модель используемого для измерения температуры термистора.
174 +* Поле "//Voltage difference//" указывает на разницу между минимальной и максимальной напряжениями ячеек.
175 +* Поле "//Temperature difference//" указывает на разницу между минимальной и максимальной температурами.
183 183  
184 -The **Commands** area contains fields for sending commands to the device, as well as error thresholds for voltage and temperature measurement:
177 +Секция **Commands **содержит поля для передачи команд устройству, а также пороговые значения погрешностей для измерения напряжения и температуры:
185 185  
186 -* Discharge all cells command to balance all cells.
187 -* Sleep put the device into sleep mode.
188 -* Wake up take the device out of sleep mode into operational mode.
189 -* Bootloader put the device into bootloader mode.
190 -* Yellow voltage difference threshold value for cell voltage measurement error for the yellow level, V.
191 -* Red voltage difference threshold value for cell voltage measurement error for the red level, V.
192 -* Yellow temperature difference threshold value for cell temperature measurement error for the yellow level, °C.
193 -* Red temperature difference threshold value for cell temperature measurement error for the red level, °C.
194 -* The "Resistance calculation" row is not used.
179 +* Discharge all cells команда на балансировку всех ячеек;
180 +* Sleep перевод устройства в режим сна;
181 +* Wake up перевод устройства из режима сна в рабочий режим;
182 +* Bootloader перевод устроства в режим загрузчика;
183 +* Yellow voltage difference пороговое значение погрешности измерения напряжения ячейки для желтого уровня, В;
184 +* Red voltage difference пороговое значение погрешности измерения напряжения ячейки для красного уровня, В;
185 +* Yellow temperature difference пороговое значение погрешности измерения температуры ячейки для желтого уровня, В;
186 +* Yellow temperature difference пороговое значение погрешности измерения температуры ячейки для красного уровня, В;
187 +* Строка "Resistance calculation" не используется.
195 195  
196 196  == BMS Display ==
197 197  
198 -The BMS Display monitor window is described in the [[BMS Display documentation>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]].
191 +Окно монитора BMS Display описано в [[документации на BMS Display>>doc:Battery management systems.BMS Display.3\. Configuration.WebHome]].
199 199  
200 200  == BMS Indication ==
201 201  
202 -The BMS Indication monitor window is described in the [[BMS Indication documentation>>doc:Battery management systems.BMS Indication.3\. Configuration.WebHome]].
195 +Окно монитора BMS Indication описано в [[документации на BMS Indication>>doc:Battery management systems.BMS Indication.3\. Configuration.WebHome]].
203 203  
204 204  == Updater ==
205 205  
206 -The updater module allows updating the firmware of BMS Mini, BMS Mini S, BMS Main X, BMS Main 2.1, BMS Logic 12/18/RET/12S, BMS Display, and BMS IMD devices through the bootloader.
199 +Модуль обновления через загрузчик позволяет обновлять встроенное ПО устройств BMS Mini, BMS Mini S, BMS Main X, BMS Main 2.1, BMS Logic 12/18/RET/12S, BMS Display, BMS IMD.
207 207  
208 -The process of updating through bootloader is described in the "Firmware Update" section of the documentation for the corresponding device (for example, [[BMS Main 2.1>>doc:Battery management systems.EOL devices.BMS Main 2\.1.4\. Firmware update.WebHome]]).
201 +Процесс обновления через загрузчик описан в разделе "Обновление ВПО" в документации на соответствующее устройство (например, [[BMS Main 2.1>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]).
209 209  
210 210  == Unified bootloader ==
211 211  
212 -The unified bootloader module allows updating the firmware of BMS Main 3 and BMS Main 3X.
205 +Модуль обновления через универсальный загрузчик позволяет обновлять встроенное ПО устройств BMS Main 3 и BMS Main 3X.
213 213  
214 -The process of updating through unified bootloader is described in the "Firmware Update" section of the [[BMS Main 3 documentation>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]].
207 +Процесс обновления через универсальный загрузчик описан в разделе "Обновление ВПО" в документации на [[BMS Main 3>>doc:Battery management systems.BMS Main 3.6\. Firmware update.WebHome]].
215 215  
216 216  == Log viewer ==
217 217  
218 -The Log Viewer module allows you to analyze device log files with the capability to plot graphs and display selected parameters in a tabular format.
211 +Модуль Log viewer позволяет анализировать лог-файлы устройства с возможностью построения графиков и табличного вывода выбранных параметров.
219 219  
220 -To get started:
213 +Для начала работы:
221 221  
222 -~1. Create a new database using the **"**New database**"** button.
215 +~1. Создайте новую базу данных с помощью кнопки «New base»
223 223  
224 224  [[image:1766062577813-983.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="135" width="226"]]
225 225  
226 -2. Enter a name for the database and select a folder to store it.
219 +2. Введите имя базы и выберите папку для хранения базы.
227 227  
228 228  [[image:1766062577815-237.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="291" width="394"]]
229 229  
230 -3. Import log files using the "Import CSV" button
223 +3. Импортируйте лог-файлы с помощью кнопки Import CSV
231 231  
232 232  [[image:1766062577817-283.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="188" width="228"]]
233 233  
234 -4. Select the log files you wish to import
227 +4. Выберите необходимые лог-файлы для импорта
235 235  
236 236  [[image:1766062577818-783.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="373"]]
237 237  
238 -To display data in graphical form, select the "Graphic view" tab. The graphs show only the parameters selected in the left part of the window. The "From" and "To" fields define the time range for which to plot the graph. The module supports both single and dual graph window modes, as well as automatic or manual vertical scaling of the graphs. The time interval displayed on the graphs can be selected in the lower right corner.
231 +Для отображения данных в графическом виде выберете вкладку "Graphic view". На графиках отображаются только выбранные в левой части окна параметры. В полях From и To задается временной диапазон, за который требуется построить график. Поддерживаются режимы одного и двух окон с графиками, а также автоматическое или ручное масштабирование графиков по вертикали. В нижнем правом углу выбирается отображаемый на графиках временной промежуток.
239 239  
240 -[[image:1766062707743-878.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="325" width="432"]]
233 +[[image:1766062707743-878.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="325" width="432"]]Для отображения данных в графическом виде выберете вкладку Table view. В полях From и To можно выбрать временной диапазон, за который требуется вывести данные. В столбцах отображаются только выбранные в левой части окна параметры.
241 241  
242 -To display data in tabular form, select the "Table view" tab. The "From" and "To" fields allow you to select the time range for which to display data. Only the parameters selected in the left part of the window are shown in the columns.
243 -
244 244  [[image:1766062736332-834.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="315" width="419"]]
245 245  {{comment}}{{/comment}}