Изменения документа BMS Mini S / BMS Mini

Редактировал(а) Admin 2025/08/11 16:41

От версии 6.2
отредактировано Admin
на 2024/12/17 12:52
Изменить комментарий: К данной версии нет комментариев
К версии 10.1
отредактировано Admin
на 2024/12/25 14:04
Изменить комментарий: К данной версии нет комментариев

Сводка

Подробности

Свойства страницы
Название
... ... @@ -1,1 +1,1 @@
1 -BMS Mini S / BMS Mini 2
1 +BMS Mini S / BMS Mini
Содержимое
... ... @@ -1,14 +1,14 @@
1 -(% class="wikigeneratedid" %)
2 -BMS Mini S / BMS Mini 2 firmware update procedure is described [[here>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]].
1 +(% class="box infomessage" %)
2 +(((
3 +BMS Mini S / BMS Mini firmware update procedure is described [[here>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]].
4 +)))
3 3  
4 -(% class="wikigeneratedid" %)
5 -v1.6.0
6 += v1.6.0 =
6 6  
7 7  (% class="wikigeneratedid" %)
8 8  [[BMS_Mini_v1.6.0.srec>>FileManager.BMS_Mini_v1\.6\.0\.srec]]
9 9  
10 -(% class="wikigeneratedid" %)
11 -Features
11 +== Features ==
12 12  
13 13  * new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section)
14 14  * new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section)
... ... @@ -17,14 +17,13 @@
17 17  * ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections)
18 18  * improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section)
19 19  * ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section)
20 +* new parameter that limits the number of battery cycles; when the number of battery cycles exceeds the limit, the BMS cannot close the charging and discharging contactors (see the "Service" section, log in under the service account)
20 20  
21 -(% class="wikigeneratedid" %)
22 -Improvements
22 +== Improvements ==
23 23  
24 24  * placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section
25 25  
26 -(% class="wikigeneratedid" %)
27 -Fixes
26 +== Fixes ==
28 28  
29 29  * using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
30 30  * resolving the problem of incorrect software signal addresses in the Modbus holding register table