Changes for page BMS Mini S / BMS Mini

Last modified by Admin on 2025/04/14 10:53

From version 6.1
edited by Admin
on 2024/12/11 13:13
Change comment: There is no comment for this version
To version 6.2
edited by Admin
on 2024/12/17 12:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,34 @@
1 1  (% class="wikigeneratedid" %)
2 2  BMS Mini S / BMS Mini 2 firmware update procedure is described [[here>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]].
3 3  
4 +(% class="wikigeneratedid" %)
5 +v1.6.0
6 +
7 +(% class="wikigeneratedid" %)
8 +[[BMS_Mini_v1.6.0.srec>>FileManager.BMS_Mini_v1\.6\.0\.srec]]
9 +
10 +(% class="wikigeneratedid" %)
11 +Features
12 +
13 +* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section)
14 +* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section)
15 +* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section
16 +* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
17 +* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections)
18 +* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section)
19 +* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section)
20 +
21 +(% class="wikigeneratedid" %)
22 +Improvements
23 +
24 +* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section
25 +
26 +(% class="wikigeneratedid" %)
27 +Fixes
28 +
29 +* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
30 +* resolving the problem of incorrect software signal addresses in the Modbus holding register table
31 +
4 4  = v1.5.1 =
5 5  