Changes for page BMS Mini S / BMS Mini

Last modified by Admin on 2025/04/14 10:53

From version 5.1
edited by Admin
on 2024/12/11 13:11
Change comment: There is no comment for this version
To version 8.1
edited by Admin
on 2024/12/19 10:59
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,31 @@
1 1  (% class="wikigeneratedid" %)
2 -BMS Mini S / BMS Mini 2 firmware update procedure is described [[here>>]].
2 +BMS Mini S / BMS Mini 2 firmware update procedure is described [[here>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]].
3 3  
4 += v1.6.0 =
5 +
6 +(% class="wikigeneratedid" %)
7 +[[BMS_Mini_v1.6.0.srec>>FileManager.BMS_Mini_v1\.6\.0\.srec]]
8 +
9 +== Features ==
10 +
11 +* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section)
12 +* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section)
13 +* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section
14 +* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
15 +* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections)
16 +* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section)
17 +* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section)
18 +* new parameter that limits the number of battery cycles; when the number of battery cycles exceeds the limit, the BMS cannot close the charging and discharging contactors (see the "Service" section, log in under the service account)
19 +
20 +== Improvements ==
21 +
22 +* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section
23 +
24 +== Fixes ==
25 +
26 +* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
27 +* resolving the problem of incorrect software signal addresses in the Modbus holding register table
28 +
4 4  = v1.5.1 =
5 5  
6 6  [[BMS_Mini_v1.5.1.srec>>FileManager.BMS_Mini_v1\.5\.1\.srec]]