... ... @@ -3,20 +3,32 @@
3 3  BMS Mini S / BMS Mini firmware update procedure is described [[here>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]].
4 4  )))
5 5  
6 += v1.10.0 =
7 +
8 +[[BMS_Mini_v1.10.0.srec>>doc:FileManager.BMS_Mini_v1\.10\.0\.srec]]
9 +
10 +== Features ==
11 +
12 +* new flag to start the heater only if "Charger connected" signal is set (see the "Control - Heater" section)
13 +* new profile section with global battery status, which includes total energy counters, total operating time, contactor switching count, etc. (see the "Profile" tab in the Unified monitor)
14 +* new error "High board temperature" which is generated when the device overheats (see the "Protection - High board temperature" section)
15 +* support for sending battery state and events via MQTT protocol via Wi-Fi or cellular network (see the "Service - MQTT" section)
16 +* support for the BMS GSM v2 cellular module
17 +
6 6  = v1.9.0 =
7 7  
8 8  [[BMS_Mini_v1.9.0.srec>>FileManager.BMS_Mini_v1\.9\.0\.srec]]
9 9  
10 -Features
22 +== Features ==
11 11  
12 -support for Svyateco Drive dashboard (see the "External equipment - Trucks and Vehicles - Svyateco Drive" section)
13 -new flag that forces the "Ready to discharge" signal to clear when the "Low SOC" signal is generated (see the "Control - Discharging status" section)
14 -new input signal "Close External 2" which generates the new internal signal "External 2" which can be assigned to a discrete output or a power switch (see the "Signals - Input discrete signals - Assignments", "Signals - Output discrete signals - Assignments", and "Signals - Power switches - Assignments" sections)
15 -ability to configure the generation of "External 1" and "External 2" signals based on other internal signals as an alternative to the "Close External 1" and "Close External 2" commands (see the "Signals - External 1-2 signals" section)
24 +* support for Svyateco Drive dashboard (see the "External equipment - Trucks and Vehicles - Svyateco Drive" section)
25 +* new flag that forces the "Ready to discharge" signal to clear when the "Low SOC" signal is generated (see the "Control - Discharging status" section)
26 +* new input signal "Close External 2" which generates the new internal signal "External 2" which can be assigned to a discrete output or a power switch (see the "Signals - Input discrete signals - Assignments", "Signals - Output discrete signals - Assignments", and "Signals - Power switches - Assignments" sections)
27 +* ability to configure the generation of "External 1" and "External 2" signals based on other internal signals as an alternative to the "Close External 1" and "Close External 2" commands (see the "Signals - External 1-2 signals" section)
16 16  
17 -Fixes
29 +== Fixes ==
18 18  
19 -resolving the problem of charge, discharge, and charge/discharge contactors closing when the "Precharge request" signal is set
31 +* resolving the problem of charge, discharge, and charge/discharge contactors closing when the "Precharge request" signal is set
20 20  
21 21  = v1.8.0 =
22 22