Changes for page BMS Mini S / BMS Mini
Last modified by Admin on 2026/05/06 12:17
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,20 +3,31 @@ 3 3 BMS Mini S / BMS Mini firmware update procedure is described [[here>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v1.10.0 = 7 + 8 +[[BMS_Mini_v1.10.0.srec>>doc:FileManager.BMS_Mini_v1\.10\.0\.srec]] 9 + 10 +=== Features === 11 + 12 +* new profile section with global battery status, which includes total energy counters, total operating time, contactor switching count, etc. (see the "Profile" tab in the Unified monitor) 13 +* new error "High board temperature" which is generated when the device overheats (see the "Protection - High board temperature" section) 14 +* support for sending battery state and events via MQTT protocol via Wi-Fi or cellular network (see the "Service - MQTT" section) 15 +* support for the BMS GSM v2 cellular module 16 + 6 6 = v1.9.0 = 7 7 8 8 [[BMS_Mini_v1.9.0.srec>>FileManager.BMS_Mini_v1\.9\.0\.srec]] 9 9 10 -Features 21 +== Features == 11 11 12 -support for Svyateco Drive dashboard (see the "External equipment - Trucks and Vehicles - Svyateco Drive" section) 13 -new flag that forces the "Ready to discharge" signal to clear when the "Low SOC" signal is generated (see the "Control - Discharging status" section) 14 -new input signal "Close External 2" which generates the new internal signal "External 2" which can be assigned to a discrete output or a power switch (see the "Signals - Input discrete signals - Assignments", "Signals - Output discrete signals - Assignments", and "Signals - Power switches - Assignments" sections) 15 -ability to configure the generation of "External 1" and "External 2" signals based on other internal signals as an alternative to the "Close External 1" and "Close External 2" commands (see the "Signals - External 1-2 signals" section) 23 +* support for Svyateco Drive dashboard (see the "External equipment - Trucks and Vehicles - Svyateco Drive" section) 24 +* new flag that forces the "Ready to discharge" signal to clear when the "Low SOC" signal is generated (see the "Control - Discharging status" section) 25 +* new input signal "Close External 2" which generates the new internal signal "External 2" which can be assigned to a discrete output or a power switch (see the "Signals - Input discrete signals - Assignments", "Signals - Output discrete signals - Assignments", and "Signals - Power switches - Assignments" sections) 26 +* ability to configure the generation of "External 1" and "External 2" signals based on other internal signals as an alternative to the "Close External 1" and "Close External 2" commands (see the "Signals - External 1-2 signals" section) 16 16 17 -Fixes 28 +== Fixes == 18 18 19 -resolving the problem of charge, discharge, and charge/discharge contactors closing when the "Precharge request" signal is set 30 +* resolving the problem of charge, discharge, and charge/discharge contactors closing when the "Precharge request" signal is set 20 20 21 21 = v1.8.0 = 22 22