Change comment: There is no comment for this version
To version 21.1
edited by Admin
on 2026/05/06 12:17
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,8 +1,69 @@
1 1  (% class="box infomessage" %)
2 2  (((
3 -BMS Mini S / BMS Mini firmware update procedure is described [[here>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]].
3 +BMS Mini S / BMS Mini firmware update procedure is described [[here>>doc:Battery management systems.BMS Mini S.6\. Firmware update.WebHome]].
4 4  )))
5 5  
6 += v1.10.1 =
7 +
8 +[[BMS_Mini_v1.10.1.srec>>FileManager.BMS_Mini_v1\.10\.1\.srec]]
9 +
10 +== Improvements ==
11 +
12 +* calculating the remaining time until the battery is completely discharged or fully charged
13 +
14 += v1.10.0 =
15 +
16 +[[BMS_Mini_v1.10.0.srec>>doc:FileManager.BMS_Mini_v1\.10\.0\.srec]]
17 +
18 +== Features ==
19 +
20 +* new flag to start the heater only if the "Charger connected" signal is set (see the "Control - Heater" section)
21 +* new profile section with global battery status, which includes total energy counters, total operating time, contactor switching count, etc. (see the "Profile" tab in the Unified monitor)
22 +* new error "High board temperature" which is generated when the device overheats (see the "Protection - High board temperature" section)
23 +* support for sending battery state and events via MQTT protocol via Wi-Fi or cellular network (see the "Service - MQTT" section)
24 +* support for the BMS GSM v2 cellular module
25 +
26 += v1.9.0 =
27 +
28 +[[BMS_Mini_v1.9.0.srec>>FileManager.BMS_Mini_v1\.9\.0\.srec]]
29 +
30 +== Features ==
31 +
32 +* support for Svyateco Drive dashboard (see the "External equipment - Trucks and Vehicles - Svyateco Drive" section)
33 +* new flag that forces the "Ready to discharge" signal to clear when the "Low SOC" signal is generated (see the "Control - Discharging status" section)
34 +* new input signal "Close External 2" which generates the new internal signal "External 2" which can be assigned to a discrete output or a power switch (see the "Signals - Input discrete signals - Assignments", "Signals - Output discrete signals - Assignments", and "Signals - Power switches - Assignments" sections)
35 +* ability to configure the generation of "External 1" and "External 2" signals based on other internal signals as an alternative to the "Close External 1" and "Close External 2" commands (see the "Signals - External 1-2 signals" section)
36 +
37 +== Fixes ==
38 +
39 +* resolving the problem of charge, discharge, and charge/discharge contactors closing when the "Precharge request" signal is set
40 +
41 += v1.8.0 =
42 +
43 +[[BMS_Mini_v1.8.0.srec>>FileManager.BMS_Mini_v1\.8\.0\.srec]]
44 +
45 +== Features ==
46 +
47 +* new protection for detecting battery cell imbalance (see the "Protections - Cell imbalance" section)
48 +* new protection checking that the number of cell temperature sensors is equal to the specified value. If this is not the case, the "T-sensor count error" is generated (see the "Protections - Temperature sensor count" section)
49 +* new internal protection that checks for overheating of MOSFETs and generates the "MOSFET error" (see the "Protections - MOSFET" section)
50 +* new internal protection that checks for power failures in the device and generates the "Power fault" error
51 +* new error "Main X offline" which is generated when the connection with BMS Main X is lost
52 +* detection of loss of wire connection to battery cells
53 +
54 +== Improvements ==
55 +
56 +* new parameters that control setting/clearing the "Ready to charge" and "Ready to discharge" signals based on the charge and/or discharge current limits (see the "Control - Charging status" and "Control - Discharging status" sections)
57 +* new parameters to ignore the specified errors when setting the critical error (see the "Protections - Critical error" section)
58 +* expansion of the list of parameters that are reset to default values when the device is powered on while holding the button on the board. The following parameters are affected: all CAN settings; all RS-485 (Modbus) settings; LAN settings: IP mode, IP address, Netmask, Gateway address
59 +* improved stability of the BMS Wi-Fi V2 driver
60 +* improved stability of the BMS GSM driver
61 +
62 +== Fixes ==
63 +
64 +* synchronization of the precharge procedure with the charge/discharge algorithms, so that precharge is stopped if charging and discharging are prohibited
65 +* resolving the problem of communication with the DC EV supply equipment
66 +
6 6  = v1.7.0 =
7 7  
8 8  [[BMS_Mini_v1.7.0.srec>>FileManager.BMS_Mini_v1\.7\.0\.srec]]