Changes for page BMS Mini S / BMS Mini
Last modified by Admin on 2025/04/14 10:53
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -BMS Mini S / BMS Mini 1 +BMS Mini S / BMS Mini 2 - Content
-
... ... @@ -1,59 +57,3 @@ 1 -(% class="box infomessage" %) 2 -((( 3 -BMS Mini S / BMS Mini firmware update procedure is described [[here>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]]. 4 -))) 5 - 6 -= v1.6.2 = 7 - 8 -[[BMS_Mini_v1.6.2.srec>>FileManager.BMS_Mini_v1\.6\.2\.srec]] 9 - 10 -== Improvements == 11 - 12 -* new parameter for setting the type of network to which the BMS GSM communication module connects (see the "Connectivity - Cellular" section) 13 -* ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error") 14 - 15 -== Fixes == 16 - 17 -* resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells) 18 - 19 -= v1.6.1 = 20 - 21 -[[BMS_Mini_v1.6.1.srec>>FileManager.BMS_Mini_v1\.6\.1\.srec]] 22 - 23 -== Improvements == 24 - 25 -* ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) 26 -* extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, IP address in Wi-Fi network, etc.) 27 - 28 -== Fixes == 29 - 30 -* small internal fixes 31 - 32 -= v1.6.0 = 33 - 34 -(% class="wikigeneratedid" %) 35 -[[BMS_Mini_v1.6.0.srec>>FileManager.BMS_Mini_v1\.6\.0\.srec]] 36 - 37 -== Features == 38 - 39 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section) 40 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section) 41 -* new Max-Min algorithm for calculating the final battery SOC in the "Control - SOC estimation" section 42 -* new flags in the "Protections - Undervoltage" and "Protections - Overvoltage" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively 43 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections) 44 -* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 45 -* ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 46 -* new parameter that limits the number of battery cycles; when the number of battery cycles exceeds the limit, the BMS cannot close the charging and discharging contactors (see the "Service" section, log in under the service account) 47 - 48 -== Improvements == 49 - 50 -* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 51 - 52 -== Fixes == 53 - 54 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 55 -* resolving the problem of incorrect software signal addresses in the Modbus holding register table 56 - 57 57 = v1.5.1 = 58 58 59 59 [[BMS_Mini_v1.5.1.srec>>FileManager.BMS_Mini_v1\.5\.1\.srec]]