Changes for page BMS Mini S / BMS Mini
Last modified by Admin on 2025/04/14 10:53
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - bms-mini1 +BMS Mini S / BMS Mini 2 - Content
-
... ... @@ -1,27 +1,14 @@ 1 -(% class="box infomessage" %) 2 -((( 3 -BMS Mini S / BMS Mini firmware update procedure is described [[here>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]]. 4 -))) 1 +(% class="wikigeneratedid" %) 2 +BMS Mini S / BMS Mini 2 firmware update procedure is described [[here>>doc:Battery management systems.BMS Mini S.5\. Firmware update.WebHome]]. 5 5 6 -= v1.6.1 = 4 +(% class="wikigeneratedid" %) 5 +v1.6.0 7 7 8 -[[BMS_Mini_v1.6.1.srec>>FileManager.BMS_Mini_v1\.6\.1\.srec]] 9 - 10 -== Improvements == 11 - 12 -* ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) 13 -* extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, IP address in Wi-Fi network, etc.) 14 - 15 -== Fixes == 16 - 17 -* small internal fixes 18 - 19 -= v1.6.0 = 20 - 21 21 (% class="wikigeneratedid" %) 22 22 [[BMS_Mini_v1.6.0.srec>>FileManager.BMS_Mini_v1\.6\.0\.srec]] 23 23 24 -== Features == 10 +(% class="wikigeneratedid" %) 11 +Features 25 25 26 26 * new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Control - Cell balancing" section) 27 27 * new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Control - Cell balancing" section) ... ... @@ -30,13 +30,14 @@ 30 30 * ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Control - Charge" and "Control - Discharge" sections) 31 31 * improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 32 32 * ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section) 33 -* new parameter that limits the number of battery cycles; when the number of battery cycles exceeds the limit, the BMS cannot close the charging and discharging contactors (see the "Service" section, log in under the service account) 34 34 35 -== Improvements == 21 +(% class="wikigeneratedid" %) 22 +Improvements 36 36 37 37 * placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 38 38 39 -== Fixes == 26 +(% class="wikigeneratedid" %) 27 +Fixes 40 40 41 41 * using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 42 42 * resolving the problem of incorrect software signal addresses in the Modbus holding register table