3 | BMS Main X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main X.5\. Firmware update.WebHome]]. | ||
4 | ))) | ||
5 | |||
![]() |
6.1 | 6 | = v2.7.0 = |
7 | |||
8 | [[BMS_Main_X2_v2.7.0.srec>>FileManager.BMS_Main_X2_v2\.7\.0\.srec]] | ||
9 | |||
10 | == Features == | ||
11 | |||
12 | * new algorithm in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithm is preferred in the battery systems with one contactor | ||
13 | * new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section | ||
14 | * new Max-Min algorithm for calculating the final battery SOC in the "Control - Calculation" section | ||
15 | * improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) | ||
16 | * ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) | ||
17 | * ability to restart the device according to a specified schedule at the moment when the battery system is preparing to charge | ||
18 | * new error "High contactor temperature" that can be used to open the specified contactor to prevent it from overheating (see the "Protections - High contactor temperature" section) | ||
19 | * new internal signal "Coolant pump" that can be assigned to a relay or discrete output (for signal settings, see the "Control - Coolant pump" section) | ||
20 | * new flags indicating the readiness of battery modules to join for charging and discharging (see the "Modules" section) | ||
21 | * new flag to set the "Voltage unbalance" errors for battery modules that are not ready to charge or discharge (see the "Protections - Voltage unbalance (in any state)" section) | ||
22 | * initial support for Pylontech inverters | ||
23 | * extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.) | ||
24 | |||
25 | == Improvements == | ||
26 | |||
27 | * ability to finish device initialization even if the number of battery modules found is less than the number of modules enabled (see the "Control - Modules" section) | ||
28 | * placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section | ||
29 | |||
30 | == Fixes == | ||
31 | |||
32 | * resolving the issue of ignoring the minimum number of battery modules allowed to join located in the "Control - Discharge" section | ||
33 | * resolving the issue of joining battery modules the number of which must be greater than or equal to the minimum value specified in the settings | ||
34 | * small internal fixes | ||
35 | |||
![]() |
4.1 | 36 | = v2.6.3 = |
37 | |||
38 | [[BMS_Main_X2_v2.6.3.srec>>FileManager.BMS_Main_X2_v2\.6\.3\.srec]] | ||
39 | |||
40 | == Improvements == | ||
41 | |||
42 | * adaptation of the device to the production test bench | ||
43 | |||
![]() |
3.1 | 44 | = v2.6.2 = |
45 | |||
46 | [[BMS_Main_X2_v2.6.2.srec>>FileManager.BMS_Main_X2_v2\.6\.2\.srec]] | ||
47 | |||
48 | == Fixes == | ||
49 | |||
50 | * resolving the problem of saving device parameters | ||
51 | |||
52 | = v2.6.1 = | ||
53 | |||
54 | [[BMS_Main_X2_v2.6.1.srec>>FileManager.BMS_Main_X2_v2\.6\.1\.srec]] | ||
55 | |||
56 | == Fixes == | ||
57 | |||
58 | * resolving the issue of preparing battery module states written to Modbus registers | ||
59 | * resolving the problem of writing the device's working time to a non-volatile memory very often | ||
60 | * resolving the problem of returning error states when saving device parameters (mainly via Wi-Fi) | ||
61 | |||
![]() |
1.2 | 62 | = v2.6.0 = |
63 | |||
64 | [[BMS_Main_X2_v2.6.0.srec>>FileManager.BMS_Main_X2_v2\.6\.0\.srec]] | ||
65 | |||
66 | == Features == | ||
67 | |||
68 | * new parameter to set the minimum number of battery modules allowed to join (see the "Control - Charge" and "Control - Discharge" sections) | ||
69 | * ability to rejoin battery modules if their voltage is close to the battery voltage (see the "Control - Charge" and "Control - Discharge" sections) | ||
70 | * selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Heater", "Control - Cooler" sections) | ||
71 | * new internal signal "General error (modules)" which is the logical sum of the "General error" signals from the battery modules | ||
72 | * new assignments "Charging", "Precharging", "Discharging", "Charging/Discharging", "Main contactor", "Critical error" and "General error (modules)" for the discrete outputs (see the "Signals - Output discrete signals - Assignments" section) | ||
73 | * new assignments "Critical error" and "General error (modules)" for the relays (see the "Signals - Relays - Assignments" section) | ||
74 | |||
![]() |
2.1 | 75 | == Improvements == |
![]() |
1.2 | 76 | |
![]() |
2.1 | 77 | * rearrangements in the settings sections, which are made to simplify the setup process |
78 | |||
79 | == Fixes == | ||
80 | |||
81 | * resolving the problem of device hanging due to high activity on the CAN bus during startup |