1 | = v2.6.3 = | ||
2 | |||
3 | [[BMS_Main_X2_v2.6.3.srec>>FileManager.BMS_Main_X2_v2\.6\.3\.srec]] | ||
4 | |||
5 | == Improvements == | ||
6 | |||
7 | * adaptation of the device to the production test bench | ||
8 | |||
9 | = v2.6.2 = | ||
10 | |||
11 | [[BMS_Main_X2_v2.6.2.srec>>FileManager.BMS_Main_X2_v2\.6\.2\.srec]] | ||
12 | |||
13 | == Fixes == | ||
14 | |||
15 | * resolving the problem of saving device parameters | ||
16 | |||
17 | = v2.6.1 = | ||
18 | |||
19 | [[BMS_Main_X2_v2.6.1.srec>>FileManager.BMS_Main_X2_v2\.6\.1\.srec]] | ||
20 | |||
21 | == Fixes == | ||
22 | |||
23 | * resolving the issue of preparing battery module states written to Modbus registers | ||
24 | * resolving the problem of writing the device's working time to a non-volatile memory very often | ||
25 | * resolving the problem of returning error states when saving device parameters (mainly via Wi-Fi) | ||
26 | |||
27 | = v2.6.0 = | ||
28 | |||
29 | [[BMS_Main_X2_v2.6.0.srec>>FileManager.BMS_Main_X2_v2\.6\.0\.srec]] | ||
30 | |||
31 | == Features == | ||
32 | |||
33 | * new parameter to set the minimum number of battery modules allowed to join (see the "Control - Charge" and "Control - Discharge" sections) | ||
34 | * ability to rejoin battery modules if their voltage is close to the battery voltage (see the "Control - Charge" and "Control - Discharge" sections) | ||
35 | * selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Heater", "Control - Cooler" sections) | ||
36 | * new internal signal "General error (modules)" which is the logical sum of the "General error" signals from the battery modules | ||
37 | * new assignments "Charging", "Precharging", "Discharging", "Charging/Discharging", "Main contactor", "Critical error" and "General error (modules)" for the discrete outputs (see the "Signals - Output discrete signals - Assignments" section) | ||
38 | * new assignments "Critical error" and "General error (modules)" for the relays (see the "Signals - Relays - Assignments" section) | ||
39 | |||
40 | == Improvements == | ||
41 | |||
42 | * rearrangements in the settings sections, which are made to simplify the setup process | ||
43 | |||