Changes for page BMS Main X
Last modified by Admin on 2025/02/19 08:28
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,81 +1,0 @@ 1 -(% class="box infomessage" %) 2 -((( 3 -BMS Main X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main X.5\. Firmware update.WebHome]]. 4 -))) 5 - 6 -= v2.7.0 = 7 - 8 -[[BMS_Main_X2_v2.7.0.srec>>FileManager.BMS_Main_X2_v2\.7\.0\.srec]] 9 - 10 -== Features == 11 - 12 -* new algorithm in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithm is preferred in the battery systems with one contactor 13 -* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 14 -* new Max-Min algorithm for calculating the final battery SOC in the "Control - Calculation" section 15 -* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 16 -* ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) 17 -* ability to restart the device according to a specified schedule at the moment when the battery system is preparing to charge 18 -* new error "High contactor temperature" that can be used to open the specified contactor to prevent it from overheating (see the "Protections - High contactor temperature" section) 19 -* new internal signal "Coolant pump" that can be assigned to a relay or discrete output (for signal settings, see the "Control - Coolant pump" section) 20 -* new flags indicating the readiness of battery modules to join for charging and discharging (see the "Modules" section) 21 -* new flag to set the "Voltage unbalance" errors for battery modules that are not ready to charge or discharge (see the "Protections - Voltage unbalance (in any state)" section) 22 -* initial support for Pylontech inverters 23 -* extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.) 24 - 25 -== Improvements == 26 - 27 -* ability to finish device initialization even if the number of battery modules found is less than the number of modules enabled (see the "Control - Modules" section) 28 -* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 29 - 30 -== Fixes == 31 - 32 -* resolving the issue of ignoring the minimum number of battery modules allowed to join located in the "Control - Discharge" section 33 -* resolving the issue of joining battery modules the number of which must be greater than or equal to the minimum value specified in the settings 34 -* small internal fixes 35 - 36 -= v2.6.3 = 37 - 38 -[[BMS_Main_X2_v2.6.3.srec>>FileManager.BMS_Main_X2_v2\.6\.3\.srec]] 39 - 40 -== Improvements == 41 - 42 -* adaptation of the device to the production test bench 43 - 44 -= v2.6.2 = 45 - 46 -[[BMS_Main_X2_v2.6.2.srec>>FileManager.BMS_Main_X2_v2\.6\.2\.srec]] 47 - 48 -== Fixes == 49 - 50 -* resolving the problem of saving device parameters 51 - 52 -= v2.6.1 = 53 - 54 -[[BMS_Main_X2_v2.6.1.srec>>FileManager.BMS_Main_X2_v2\.6\.1\.srec]] 55 - 56 -== Fixes == 57 - 58 -* resolving the issue of preparing battery module states written to Modbus registers 59 -* resolving the problem of writing the device's working time to a non-volatile memory very often 60 -* resolving the problem of returning error states when saving device parameters (mainly via Wi-Fi) 61 - 62 -= v2.6.0 = 63 - 64 -[[BMS_Main_X2_v2.6.0.srec>>FileManager.BMS_Main_X2_v2\.6\.0\.srec]] 65 - 66 -== Features == 67 - 68 -* new parameter to set the minimum number of battery modules allowed to join (see the "Control - Charge" and "Control - Discharge" sections) 69 -* ability to rejoin battery modules if their voltage is close to the battery voltage (see the "Control - Charge" and "Control - Discharge" sections) 70 -* selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Heater", "Control - Cooler" sections) 71 -* new internal signal "General error (modules)" which is the logical sum of the "General error" signals from the battery modules 72 -* new assignments "Charging", "Precharging", "Discharging", "Charging/Discharging", "Main contactor", "Critical error" and "General error (modules)" for the discrete outputs (see the "Signals - Output discrete signals - Assignments" section) 73 -* new assignments "Critical error" and "General error (modules)" for the relays (see the "Signals - Relays - Assignments" section) 74 - 75 -== Improvements == 76 - 77 -* rearrangements in the settings sections, which are made to simplify the setup process 78 - 79 -== Fixes == 80 - 81 -* resolving the problem of device hanging due to high activity on the CAN bus during startup