Changes for page BMS Main X
Last modified by Admin on 2025/05/28 10:39
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,0 +1,106 @@ 1 +(% class="box infomessage" %) 2 +((( 3 +BMS Main X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main X.5\. Firmware update.WebHome]]. 4 +))) 5 + 6 += v2.8.0 = 7 + 8 +[[BMS_Main_X2_v2.8.0.srec>>FileManager.BMS_Main_X2_v2\.8\.0\.srec]] 9 + 10 +== Features == 11 + 12 +* new flags that allow to interrupt (shorten) the module balancing stage if all battery modules are already joined (see the "Control - Charge", "Control - Discharge", "Control - Charge/Discharge" sections) 13 +* forwarding CLI and bootloader CAN messages from CAN EXT interface to CAN INT interface and back 14 +* new parameter for setting the type of network to which the BMS GSM communication module connects (see the "Connectivity - Cellular" section) 15 +* new flag that controls whether to use open circuit voltage or actual voltage when determining the voltage unbalance error (see the "Protections - Voltage unbalance (in any state)" section) 16 +* new regulator that maintains battery current limiting to ensure that actual module currents do not exceed their current limits (see the "Control - Charge", "Control - Discharge", "Control - Charge/Discharge" sections) 17 +* ability to select the battery module errors that cause the battery critical error (see the "Protections - Critical error" section) 18 +* ability to update the device serial number from the service account if the number is reset to the default value for some reason (see the "Service" section) 19 + 20 +== Improvements == 21 + 22 +* dynamic calculation of data transfer schedule for optimal communication with a large number of battery modules 23 +* ability to complete device initialization after the set timeout has expired and the minimum number of modules has been detected (see the "Control - Initialization" section) 24 +* 30 second delay when remounting SD card after detecting mount error 25 +* saving the number of joined modules in log files 26 + 27 +== Fixes == 28 + 29 +* resolving the issue of saving some battery module signals in log files 30 + 31 += v2.7.0 = 32 + 33 +[[BMS_Main_X2_v2.7.0.srec>>FileManager.BMS_Main_X2_v2\.7\.0\.srec]] 34 + 35 +== Features == 36 + 37 +* new algorithm in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithm is preferred in the battery systems with one contactor 38 +* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 39 +* new Max-Min algorithm for calculating the final battery SOC in the "Control - Calculation" section 40 +* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 41 +* ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) 42 +* ability to restart the device according to a specified schedule at the moment when the battery system is preparing to charge 43 +* new error "High contactor temperature" that can be used to open the specified contactor to prevent it from overheating (see the "Protections - High contactor temperature" section) 44 +* new internal signal "Coolant pump" that can be assigned to a relay or discrete output (for signal settings, see the "Control - Coolant pump" section) 45 +* new flags indicating the readiness of battery modules to join for charging and discharging (see the "Modules" section) 46 +* new flag to set the "Voltage unbalance" errors for battery modules that are not ready to charge or discharge (see the "Protections - Voltage unbalance (in any state)" section) 47 +* initial support for Pylontech inverters 48 +* extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.) 49 + 50 +== Improvements == 51 + 52 +* ability to finish device initialization even if the number of battery modules found is less than the number of modules enabled (see the "Control - Modules" section) 53 +* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 54 + 55 +== Fixes == 56 + 57 +* resolving the issue of ignoring the minimum number of battery modules allowed to join located in the "Control - Discharge" section 58 +* resolving the issue of joining battery modules the number of which must be greater than or equal to the minimum value specified in the settings 59 +* small internal fixes 60 + 61 += v2.6.3 = 62 + 63 +[[BMS_Main_X2_v2.6.3.srec>>FileManager.BMS_Main_X2_v2\.6\.3\.srec]] 64 + 65 +== Improvements == 66 + 67 +* adaptation of the device to the production test bench 68 + 69 += v2.6.2 = 70 + 71 +[[BMS_Main_X2_v2.6.2.srec>>FileManager.BMS_Main_X2_v2\.6\.2\.srec]] 72 + 73 +== Fixes == 74 + 75 +* resolving the problem of saving device parameters 76 + 77 += v2.6.1 = 78 + 79 +[[BMS_Main_X2_v2.6.1.srec>>FileManager.BMS_Main_X2_v2\.6\.1\.srec]] 80 + 81 +== Fixes == 82 + 83 +* resolving the issue of preparing battery module states written to Modbus registers 84 +* resolving the problem of writing the device's working time to a non-volatile memory very often 85 +* resolving the problem of returning error states when saving device parameters (mainly via Wi-Fi) 86 + 87 += v2.6.0 = 88 + 89 +[[BMS_Main_X2_v2.6.0.srec>>FileManager.BMS_Main_X2_v2\.6\.0\.srec]] 90 + 91 +== Features == 92 + 93 +* new parameter to set the minimum number of battery modules allowed to join (see the "Control - Charge" and "Control - Discharge" sections) 94 +* ability to rejoin battery modules if their voltage is close to the battery voltage (see the "Control - Charge" and "Control - Discharge" sections) 95 +* selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Heater", "Control - Cooler" sections) 96 +* new internal signal "General error (modules)" which is the logical sum of the "General error" signals from the battery modules 97 +* new assignments "Charging", "Precharging", "Discharging", "Charging/Discharging", "Main contactor", "Critical error" and "General error (modules)" for the discrete outputs (see the "Signals - Output discrete signals - Assignments" section) 98 +* new assignments "Critical error" and "General error (modules)" for the relays (see the "Signals - Relays - Assignments" section) 99 + 100 +== Improvements == 101 + 102 +* rearrangements in the settings sections, which are made to simplify the setup process 103 + 104 +== Fixes == 105 + 106 +* resolving the problem of device hanging due to high activity on the CAN bus during startup