Last modified by Admin on 2025/02/19 08:28
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,0 +1,81 @@ 1 +(% class="box infomessage" %) 2 +((( 3 +BMS Main X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main X.5\. Firmware update.WebHome]]. 4 +))) 5 + 6 += v2.7.0 = 7 + 8 +[[BMS_Main_X2_v2.7.0.srec>>FileManager.BMS_Main_X2_v2\.7\.0\.srec]] 9 + 10 +== Features == 11 + 12 +* new algorithm in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithm is preferred in the battery systems with one contactor 13 +* new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section 14 +* new Max-Min algorithm for calculating the final battery SOC in the "Control - Calculation" section 15 +* improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section) 16 +* ability to exclude errors from being saved in the error journal (see the "Service - Errors journal" section) 17 +* ability to restart the device according to a specified schedule at the moment when the battery system is preparing to charge 18 +* new error "High contactor temperature" that can be used to open the specified contactor to prevent it from overheating (see the "Protections - High contactor temperature" section) 19 +* new internal signal "Coolant pump" that can be assigned to a relay or discrete output (for signal settings, see the "Control - Coolant pump" section) 20 +* new flags indicating the readiness of battery modules to join for charging and discharging (see the "Modules" section) 21 +* new flag to set the "Voltage unbalance" errors for battery modules that are not ready to charge or discharge (see the "Protections - Voltage unbalance (in any state)" section) 22 +* initial support for Pylontech inverters 23 +* extension of the CANopen dictionary to provide additional information for the BMS Display (device serial number, battery serial number, battery address, Wi-Fi and LAN addresses, SOH, capacity, etc.) 24 + 25 +== Improvements == 26 + 27 +* ability to finish device initialization even if the number of battery modules found is less than the number of modules enabled (see the "Control - Modules" section) 28 +* placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section 29 + 30 +== Fixes == 31 + 32 +* resolving the issue of ignoring the minimum number of battery modules allowed to join located in the "Control - Discharge" section 33 +* resolving the issue of joining battery modules the number of which must be greater than or equal to the minimum value specified in the settings 34 +* small internal fixes 35 + 36 += v2.6.3 = 37 + 38 +[[BMS_Main_X2_v2.6.3.srec>>FileManager.BMS_Main_X2_v2\.6\.3\.srec]] 39 + 40 +== Improvements == 41 + 42 +* adaptation of the device to the production test bench 43 + 44 += v2.6.2 = 45 + 46 +[[BMS_Main_X2_v2.6.2.srec>>FileManager.BMS_Main_X2_v2\.6\.2\.srec]] 47 + 48 +== Fixes == 49 + 50 +* resolving the problem of saving device parameters 51 + 52 += v2.6.1 = 53 + 54 +[[BMS_Main_X2_v2.6.1.srec>>FileManager.BMS_Main_X2_v2\.6\.1\.srec]] 55 + 56 +== Fixes == 57 + 58 +* resolving the issue of preparing battery module states written to Modbus registers 59 +* resolving the problem of writing the device's working time to a non-volatile memory very often 60 +* resolving the problem of returning error states when saving device parameters (mainly via Wi-Fi) 61 + 62 += v2.6.0 = 63 + 64 +[[BMS_Main_X2_v2.6.0.srec>>FileManager.BMS_Main_X2_v2\.6\.0\.srec]] 65 + 66 +== Features == 67 + 68 +* new parameter to set the minimum number of battery modules allowed to join (see the "Control - Charge" and "Control - Discharge" sections) 69 +* ability to rejoin battery modules if their voltage is close to the battery voltage (see the "Control - Charge" and "Control - Discharge" sections) 70 +* selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Heater", "Control - Cooler" sections) 71 +* new internal signal "General error (modules)" which is the logical sum of the "General error" signals from the battery modules 72 +* new assignments "Charging", "Precharging", "Discharging", "Charging/Discharging", "Main contactor", "Critical error" and "General error (modules)" for the discrete outputs (see the "Signals - Output discrete signals - Assignments" section) 73 +* new assignments "Critical error" and "General error (modules)" for the relays (see the "Signals - Relays - Assignments" section) 74 + 75 +== Improvements == 76 + 77 +* rearrangements in the settings sections, which are made to simplify the setup process 78 + 79 +== Fixes == 80 + 81 +* resolving the problem of device hanging due to high activity on the CAN bus during startup