Wiki source code of BMS Main 3X

Version 6.2 by Admin on 2024/12/19 12:15

Show last authors
1 (% class="wikigeneratedid" %)
2 BMS Main 3X firmware update procedure is described [[here>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%203/5.%20Firmware%20update/]].
3
4 (% class="wikigeneratedid" %)
5 v3.2.0
6
7 (% class="wikigeneratedid" %)
8 [[BMS_Main_3X_v3.2.0.bin>>FileManager.BMS_Main_3X_v3\.2\.0\.bin]]
9
10 == Features ==
11
12 * new algorithm in the Charging/Discharging controller that allow to control the Charging/Discharging contactor independently from the Charging and Discharging signals (see the "Control - Charge/Discharge" section). The new "Independent" algorithm is preferred in the battery systems with one contactor
13 * new "Need acknowledge" warning signal that is set when a new record is created in the errors journal. The signal can be cleared in the "Service - Errors journal" section
14 * new Max-Min algorithm for calculating the final battery SOC in the "Control - Calculation" section
15 * improved control of the precharging contactor, which can precharge capacitive load using multiple attempts and detect high power dissipated in the precharge resistor (see the "Control - Precharge" section)
16 * ability to select errors that the device saves in the errors journal (see the "Service - Errors journal" section)
17
18 == Improvements ==
19
20 * ability to finish device initialization even if the number of battery modules found is less than the number of modules enabled
21 * ability to configure and monitor the device via the CAN1 (ext) bus
22 * placing the device input signals to the "Battery" section and adding raw discrete inputs to the "Signals" section
23 * Unibat: support for functional description v3.5 (protocol v1.5)
24
25 = v3.1.1 =
26
27 [[BMS_Main_3X_v3.1.1.bin>>FileManager.BMS_Main_3X_v3\.1\.1\.bin]]
28
29 == Fixes ==
30
31 * resolving the problem of incorrect range of temperature parameter values (in the "Control - Coolant pump" section)
32 * resolving the possible problem of saving device parameters
33 * resolving the problem of writing the device's working time to a non-volatile memory very often
34 * resolving the issue of preparing battery module states written to Modbus registers
35
36 = v3.1.0 =
37
38 [[BMS_Main_3X_v3.1.0.bin>>FileManager.BMS_Main_3X_v3\.1\.0\.bin]]
39
40 == Features ==
41
42 * new parameter to set the minimum number of battery modules allowed to join (see the "Control - Charge" and "Control - Discharge" sections)
43 * ability to rejoin battery modules if their voltage is close to the battery voltage (see the "Control - Charge" and "Control - Discharge" sections)
44 * selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Heater", "Control - Cooler", "Control - Coolant pump" sections)
45 * new internal signal "General error (modules)" which is the logical sum of the "General error" signals from the battery modules
46 * new assignments "Critical error" and "General error (modules)" for the discrete outputs and power switches (see the "Signals - Output discrete signals - Assignments" and "Signals - Power switches - Assignments" sections)
47
48 == Improvements ==
49
50 * use the measured voltage before contactors as the battery voltage if the "Control - High voltage" function is enabled
51 * Unibat: new flag to enable sending a control message to start/stop ventilation fans installed in the battery modules (see the "External equipment - Unibat vehicle" section)
52 * rearrangements in the settings sections, which are made to simplify the setup process
53
54 == Fixes ==
55
56 * Unibat: minor changes in the communication protocol